Product
Automatically implement high -precision distillation analysis under atmospheric pressure DianaHandling Company
Anton Paar GmbHItems marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Ambient temperature | Automatic calculation | Condensation tube system | Fire extinguisher | Heating system | Interview cooling bathtub | Operation condition consumption consumption | Operation condition elevation | Operation condition relative humidity | Operation condition temperature | Operation condition voltage | Peripheral pressure | Relative humidity around | Sample capacity | Standard test method | Status light | Status monitoring system | Steam temperature | Test results | User definition test method | User interface | accessory | connection | size | weight |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
239541 |
Available upon quote | Built -in temperature sensor, temperature range: -20 ° C ~+80 ° C, decomposition ability: 0.1 ℃ | Cetan index, driverability index | Cooling without refrigerant by Peltier technology, temperature range: 0 ° C to 80 ° C, decomposition ability: 0.1 ℃ |
Built -in fire extinguishing system with an IR sensor for fire detection Connection of 4 to 6 Bar CO2 or N2 |
Low -quality/low -voltage heating system, automatic initial heater setting, heater control, and cooling fan that can be handled safely after testing. | Cooling without refrigerant by Peltier technology, temperature range: 0 ° C ~ 80 ° C, decomposition ability: 0.1 ° C, automation of bodies, automation of release reduction of VOC | 900 | 0 m ~ 5,000 m | Relative humidity 10 % to 80 % (35 ° C) | 10 ℃ ~ 35 ℃ | 100 V ~ 240 V, 50/60 Hz | Built -in pressure sensor, range: 30 kpa ~ 110 kpa, resolution ability: 0.1 kpa | Built -in humidity sensor, range: 0 % to 95 % (relative humidity) | The initial volume is measured with a sample volume scan before the start of the test, the loss is calculated by scanning the residue in the receiver cooling bathtub, the capacity range: 0 ~ 103.5 ml, resolution: 0.01 ml, accuracy: ± 0.1 ml | ASTM D86 (GROUP 0, 1, 2, 3, 4), ASTM D850, ASTM D1,078, EN ISO 3,405 (Group 0, 1, 2, 3, 4), IP 123, etc. | yes | Frask size, flask support plate, steam temperature sensor, heater shield, heater lift, condensed tube cleaning, driver's cooling bathtub, receiver cylinder, dropplate, fire extinguishing gas. | PT100, class A (metal or glass) temperature range: 0 ℃ ~ 450 ° C, decomposition ability: 0.1 ° C. 20 points and automatic reading (ID detection) Automatic correction with built -in calibration. | > 4,000 | > 200 | 10 inch TFT color touch screen, solution resistant | Dry point detection sensor, 200 mL flask, barcode reader, printer, receipt printer, keyboard, various authentication standard substances (CRM) | 1 × Ethernet, 4 × USB, Bluetooth, Wi-Fi, AP Connect, Lims | Approximately 406 mm x 525 mm x 645 mm (width x depth x height) | Approximately 40 kg | |
253515 |
Available upon quote | Built -in temperature sensor, temperature range: -20 ° C ~+80 ° C, decomposition ability: 0.1 ℃ | - | Cooling without refrigerant by Peltier technology, temperature range: 0 ° C to 80 ° C, decomposition ability: 0.1 ℃ |
Built -in fire extinguishing system with an IR sensor for fire detection Connection of 4 to 6 Bar CO2 or N2 |
Low -quality/low -voltage heating system with a manual position adjustment function of a heater and safety shield, initial heater settings programmed in advance in the test method | Cooling without refrigerant by Peltier technology, temperature range: 0 ° C ~ 80 ° C, decomposition ability: 0.1 ° C, automation of bodies, automation of release reduction of VOC | 900 | 0 m ~ 5,000 m | Relative humidity 10 % to 80 % (35 ° C) | 10 ℃ ~ 35 ℃ | 100 V ~ 240 V, 50/60 Hz | Built -in pressure sensor, range: 30 kpa ~ 110 kpa, resolution ability: 0.1 kpa | Built -in humidity sensor, range: 0 % to 95 % (relative humidity) | Capacity range: 0 ml to 100 ml, decomposition ability: 0.01 ml, accuracy: ± 0.1 ml | ASTM D86 (Group 0, 2, 3, 4), EN ISO 3,405 (Group 0, 2, 3, 4), IP 123, JIS K 2,254, Gost 2,177 | no | Steam temperature sensor, door -to -air bathtub door, cylinder for receiver, drip plate | PT100, class A (glass) temperature range: 0 ℃ ~ 450 ° C, resolution ability: 0.1 ℃ Automatic correction by air pressure | 200 | 15 | 10 inch TFT color touch screen, solution resistant | Bar code reader, printer, receipt printer, keyboard, various authentication standard substances (CRM) | 2 x USB | Approximately 406 mm x 525 mm x 645 mm (width x depth x height) | Approximately 40 kg |
Click on the part number for more information about each product