Product
Particle -like substance sensor HPM series that can be handled in real time for environmental changesHandling Company
Krone Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Accuracy (25 ° C ± 5 ℃): 0 to 100 μg/m3 | Accuracy (25 ° C ± 5 ℃): 100-1000μg/m3 | Concentration range | Conduction noise | Dimensions (length x width x height) | ESD | Equity radiation emissions for conduction obstruction | Fast Lotus/Burst | Humidity (operation and preservation) | Laser class | Maximum rush current (at 25 ° C ± 5 ° C) | Maximum switching frequency | Operating principle | Operating time: continuous mode | Operating time: intermittent mode | Output protocol | Power-supply voltage | R.M.S. noise maximum value | Radiation noise | Radioactive system | Response time | Ripple amplitude maximum value | Standby current (at 25 ° C ± 5 ° C) | Supply current (at 25 ° C ± 5 ° C) | Temperature: Operation | Temperature: Save | detection | output data |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
HPMA115S0 |
Available upon quote | PM2.5: ± 15 µg/m3 | PM2.5: ± 15% | 0 µg/m3 ~ 1,000 µg/m3 | 0.15 MHz ~ 30 MHz (Cispr 14 compliant) |
43 mm x 36,00 mm x 23,7 mm [1.69 in x 1.42 in x 0.93 in] |
± 4 KV Contact, ± 8 KV Air (IEC 61000-4-2 compliant) | 3 V (IEC61000-4-6 compliant) | ± 0.5 kv (IEC61000-4-4 compliant) | 0%RH ~ 95%RH Dew condensation | Laser Class 1: IEC/EN 60825-1: 650 Nm | 600 ma | 100 kHz | Laser scattering | About 10 years | Relying on duty cycle | UART; Bore rate: 9600, Data Bit: 8, Stop bit: 1, Parity: None | 5 v ± 0.2 v | 1 MV (noise bandwidth 10 MHz) | 40 DB 30 MHz ~ 230 MHz; 47 DB 230 MHz ~ 1000 MHz (Cispr 14 compliant) | 1 V/M (80 MHz ~ 1000 MHz) IEC 61000-4-3 compliant | <6 s | 20 MV | <20 MA | <80 ma | -20 ℃ ~ 50 ° C [-4 ° f ~ 122 ° f] | -30 ℃ ~ 65 ° C [-22 ° f ~ 149 ° f] | PM2.5, PM10 | PM2.5 in µg/m3, PM10 in µg/m3 | |
HPMA115C0-003 |
Available upon quote | PM2.5: ± 15µg/m3; PM1.0, PM4.0, PM10: ± 25 µg/m3 | PM2.5: ± 15%; PM1.0, PM4.0, PM10: ± 25%; | 0 µg/m3 ~ 1,000 µg/m3 | 0.15 MHz ~ 30 MHz (Cispr 14 compliant) |
44 mm x 36 mm x 12 mm [1.73 in x 1.42 in x 0.48 in] |
± 4 KV Contact, ± 8 KV Air (IEC 61000-4-2 compliant) | 3 V (IEC61000-4-6 compliant) | ± 0.5 kv (IEC61000-4-4 compliant) | 0%RH ~ 95%RH Dew condensation | Laser Class 1: IEC/EN 60825-1: 650 Nm | 600 ma | 100 kHz | Laser scattering | About 10 years | Relying on duty cycle | UART; Bore rate: 9600, Data Bit: 8, Stop bit: 1, Parity: None | 5 v ± 0.2 v | 1 MV (noise bandwidth 10 MHz) | 40 DB 30 MHz ~ 230 MHz; 47 DB 230 MHz ~ 1000 MHz (Cispr 14 compliant) | 1 V/M (80 MHz ~ 1000 MHz) IEC 61000-4-3 compliant | <6 s | 20 MV | <20 MA | <80 ma | -20 ℃ ~ 70 ° C [-4 ° f ~ 158 ° f] | -40 ℃ ~ 85 ° C [-40 ° f ~ 185 ° f] | PM1.0, PM2.5, PM4.0, PM10 | PM1.0 in µg/m3, PM2.5 in µg/m3, pm4.0 in µg/m3, pm10 in µg/m3 | |
HPMA115C0-004 |
Available upon quote | PM2.5: ± 15µg/m3; PM1.0, PM4.0, PM10: ± 25 µg/m3 | PM2.5: ± 15%; PM1.0, PM4.0, PM10: ± 25%; | 0 µg/m3 ~ 1,000 µg/m3 | 0.15 MHz ~ 30 MHz (Cispr 14 compliant) |
44 mm x 36 mm x 12 mm [1.73 in x 1.42 in x 0.48 in] |
± 4 KV Contact, ± 8 KV Air (IEC 61000-4-2 compliant) | 3 V (IEC61000-4-6 compliant) | ± 0.5 kv (IEC61000-4-4 compliant) | 0%RH ~ 95%RH Dew condensation | Laser Class 1: IEC/EN 60825-1: 650 Nm | 600 ma | 100 kHz | Laser scattering | About 10 years | Relying on duty cycle | UART; Bore rate: 9600, Data Bit: 8, Stop bit: 1, Parity: None | 5 v ± 0.2 v | 1 MV (noise bandwidth 10 MHz) | 40 DB 30 MHz ~ 230 MHz; 47 DB 230 MHz ~ 1000 MHz (Cispr 14 compliant) | 1 V/M (80 MHz ~ 1000 MHz) IEC 61000-4-3 compliant | <6 s | 20 MV | <20 MA | <80 ma | -20 ℃ ~ 70 ° C [-4 ° f ~ 158 ° f] | -40 ℃ ~ 85 ° C [-40 ° f ~ 185 ° f] | PM1.0, PM2.5, PM4.0, PM10 | PM1.0 in µg/m3, PM2.5 in µg/m3, pm4.0 in µg/m3, pm10 in µg/m3 |
Click on the part number for more information about each product