Product
Kalman whirlpool -type flow meter 210 series for water and drinking water flow and temperature measurementHandling Company
Krone Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | External dimension 1D | External dimensions 2D | External dimensions 3D | External dimensions 4D | External dimensions 5D | Flow range range | Maximum pressure / fluid temperature | Measurement medium | Termeter / 0 ... 10V | Termeter / 4 ... 20ma | Termeter / PT1000 | accuracy | others | output | temperature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DN6 K |
Available upon quote | 33.3 | 53 | G½ | 77 | 12 | 0.5 ~ 10L ... 150L/min |
40 ° C / 1.2MPa At 100 ° C / 0.6MPa 125 ° C time / 0.4MPa (600 hours) 140 ° C time / 0.4MPa (2 hours) Maximum pressure test 40 ° C at 1.8MPa |
Drinking water or water |
Measurement range -25 ... + 125 ℃ Accuracy -25 ... + 125 ℃ |
Measurement range -25 ... + 125 ℃ Accuracy ± 0.5k ± 0.005 × | T | |
Measurement range -40 ... + 125 ℃ Accuracy@T = 0 ℃ ± 0.3 @T ≠ 0 ℃ ± 0.3k ± 0.005 × | T | T | |
Frequency 50%F.S. 1%of full scale 50%F.S. 2%of the measured values |
There is a flow rate, temperature sensor type | Select from voltage, current, pulse |
Media < + 125 ℃ Viper temperature -15 ... + 85 ℃ Save temperature -30 ... + 85 ℃ |
|
DN8 k |
Available upon quote | 33.3 | 53 | G½ | 77 | 12 | 0.5 ~ 10L ... 150L/min |
40 ° C / 1.2MPa At 100 ° C / 0.6MPa 125 ° C time / 0.4MPa (600 hours) 140 ° C time / 0.4MPa (2 hours) Maximum pressure test 40 ° C at 1.8MPa |
Drinking water or water |
Measurement range -25 ... + 125 ℃ Accuracy -25 ... + 125 ℃ |
Measurement range -25 ... + 125 ℃ Accuracy ± 0.5k ± 0.005 × | T | |
Measurement range -40 ... + 125 ℃ Accuracy@T = 0 ℃ ± 0.3 @T ≠ 0 ℃ ± 0.3k ± 0.005 × | T | T | |
Frequency 50%F.S. 1%of full scale 50%F.S. 2%of the measured values |
There is a flow rate, temperature sensor type | Select from voltage, current, pulse |
Media < + 125 ℃ Viper temperature -15 ... + 85 ℃ Save temperature -30 ... + 85 ℃ |
|
DN8 G |
Available upon quote | 37.8 | 55.7 | G¾ | 86 | 12 | 0.5 ~ 10L ... 150L/min |
40 ° C / 1.2MPa At 100 ° C / 0.6MPa 125 ° C time / 0.4MPa (600 hours) 140 ° C time / 0.4MPa (2 hours) Maximum pressure test 40 ° C at 1.8MPa |
Drinking water or water |
Measurement range -25 ... + 125 ℃ Accuracy -25 ... + 125 ℃ |
Measurement range -25 ... + 125 ℃ Accuracy ± 0.5k ± 0.005 × | T | |
Measurement range -40 ... + 125 ℃ Accuracy@T = 0 ℃ ± 0.3 @T ≠ 0 ℃ ± 0.3k ± 0.005 × | T | T | |
Frequency 50%F.S. 1%of full scale 50%F.S. 2%of the measured values |
There is a flow rate, temperature sensor type | Select from voltage, current, pulse |
Media < + 125 ℃ Viper temperature -15 ... + 85 ℃ Save temperature -30 ... + 85 ℃ |
|
DN10 K |
Available upon quote | 35 | 51.3 | G½ | 81 | 12 | 0.5 ~ 10L ... 150L/min |
40 ° C / 1.2MPa At 100 ° C / 0.6MPa 125 ° C time / 0.4MPa (600 hours) 140 ° C time / 0.4MPa (2 hours) Maximum pressure test 40 ° C at 1.8MPa |
Drinking water or water |
Measurement range -25 ... + 125 ℃ Accuracy -25 ... + 125 ℃ |
Measurement range -25 ... + 125 ℃ Accuracy ± 0.5k ± 0.005 × | T | |
Measurement range -40 ... + 125 ℃ Accuracy@T = 0 ℃ ± 0.3 @T ≠ 0 ℃ ± 0.3k ± 0.005 × | T | T | |
Frequency 50%F.S. 1%of full scale 50%F.S. 2%of the measured values |
There is a flow rate, temperature sensor type | Select from voltage, current, pulse |
Media < + 125 ℃ Viper temperature -15 ... + 85 ℃ Save temperature -30 ... + 85 ℃ |
|
DN10 G |
Available upon quote | 39.5 | 54.1 | G¾ | 90 | 12 | 0.5 ~ 10L ... 150L/min |
40 ° C / 1.2MPa At 100 ° C / 0.6MPa 125 ° C time / 0.4MPa (600 hours) 140 ° C time / 0.4MPa (2 hours) Maximum pressure test 40 ° C at 1.8MPa |
Drinking water or water |
Measurement range -25 ... + 125 ℃ Accuracy -25 ... + 125 ℃ |
Measurement range -25 ... + 125 ℃ Accuracy ± 0.5k ± 0.005 × | T | |
Measurement range -40 ... + 125 ℃ Accuracy@T = 0 ℃ ± 0.3 @T ≠ 0 ℃ ± 0.3k ± 0.005 × | T | T | |
Frequency 50%F.S. 1%of full scale 50%F.S. 2%of the measured values |
There is a flow rate, temperature sensor type | Select from voltage, current, pulse |
Media < + 125 ℃ Viper temperature -15 ... + 85 ℃ Save temperature -30 ... + 85 ℃ |
|
DN15 K |
Available upon quote | 36.6 | 56.1 | G¾ | 87 | 16 | 0.5 ~ 10L ... 150L/min |
40 ° C / 1.2MPa At 100 ° C / 0.6MPa 125 ° C time / 0.4MPa (600 hours) 140 ° C time / 0.4MPa (2 hours) Maximum pressure test 40 ° C at 1.8MPa |
Drinking water or water |
Measurement range -25 ... + 125 ℃ Accuracy -25 ... + 125 ℃ |
Measurement range -25 ... + 125 ℃ Accuracy ± 0.5k ± 0.005 × | T | |
Measurement range -40 ... + 125 ℃ Accuracy@T = 0 ℃ ± 0.3 @T ≠ 0 ℃ ± 0.3k ± 0.005 × | T | T | |
Frequency 50%F.S. 1%of full scale 50%F.S. 2%of the measured values |
There is a flow rate, temperature sensor type | Select from voltage, current, pulse |
Media < + 125 ℃ Viper temperature -15 ... + 85 ℃ Save temperature -30 ... + 85 ℃ |
|
DN15 G |
Available upon quote | 41.6 | 59.5 | G1 | 97 | 16 | 0.5 ~ 10L ... 150L/min |
40 ° C / 1.2MPa At 100 ° C / 0.6MPa 125 ° C time / 0.4MPa (600 hours) 140 ° C time / 0.4MPa (2 hours) Maximum pressure test 40 ° C at 1.8MPa |
Drinking water or water |
Measurement range -25 ... + 125 ℃ Accuracy -25 ... + 125 ℃ |
Measurement range -25 ... + 125 ℃ Accuracy ± 0.5k ± 0.005 × | T | |
Measurement range -40 ... + 125 ℃ Accuracy@T = 0 ℃ ± 0.3 @T ≠ 0 ℃ ± 0.3k ± 0.005 × | T | T | |
Frequency 50%F.S. 1%of full scale 50%F.S. 2%of the measured values |
There is a flow rate, temperature sensor type | Select from voltage, current, pulse |
Media < + 125 ℃ Viper temperature -15 ... + 85 ℃ Save temperature -30 ... + 85 ℃ |
|
DN20 K |
Available upon quote | 36.6 | 61.5 | G1 | 105 | 20 | 0.5 ~ 10L ... 150L/min |
40 ° C / 1.2MPa At 100 ° C / 0.6MPa 125 ° C time / 0.4MPa (600 hours) 140 ° C time / 0.4MPa (2 hours) Maximum pressure test 40 ° C at 1.8MPa |
Drinking water or water |
Measurement range -25 ... + 125 ℃ Accuracy -25 ... + 125 ℃ |
Measurement range -25 ... + 125 ℃ Accuracy ± 0.5k ± 0.005 × | T | |
Measurement range -40 ... + 125 ℃ Accuracy@T = 0 ℃ ± 0.3 @T ≠ 0 ℃ ± 0.3k ± 0.005 × | T | T | |
Frequency 50%F.S. 1%of full scale 50%F.S. 2%of the measured values |
There is a flow rate, temperature sensor type | Select from voltage, current, pulse |
Media < + 125 ℃ Viper temperature -15 ... + 85 ℃ Save temperature -30 ... + 85 ℃ |
|
DN20 G |
Available upon quote | 42.6 | 65.8 | G¼ | 117 | 20 | 0.5 ~ 10L ... 150L/min |
40 ° C / 1.2MPa At 100 ° C / 0.6MPa 125 ° C time / 0.4MPa (600 hours) 140 ° C time / 0.4MPa (2 hours) Maximum pressure test 40 ° C at 1.8MPa |
Drinking water or water |
Measurement range -25 ... + 125 ℃ Accuracy -25 ... + 125 ℃ |
Measurement range -25 ... + 125 ℃ Accuracy ± 0.5k ± 0.005 × | T | |
Measurement range -40 ... + 125 ℃ Accuracy@T = 0 ℃ ± 0.3 @T ≠ 0 ℃ ± 0.3k ± 0.005 × | T | T | |
Frequency 50%F.S. 1%of full scale 50%F.S. 2%of the measured values |
There is a flow rate, temperature sensor type | Select from voltage, current, pulse |
Media < + 125 ℃ Viper temperature -15 ... + 85 ℃ Save temperature -30 ... + 85 ℃ |
|
DN25 K |
Available upon quote | 50 | 68.3 | G¼ | 120 | 26 | 0.5 ~ 10L ... 150L/min |
40 ° C / 1.2MPa At 100 ° C / 0.6MPa 125 ° C time / 0.4MPa (600 hours) 140 ° C time / 0.4MPa (2 hours) Maximum pressure test 40 ° C at 1.8MPa |
Drinking water or water |
Measurement range -25 ... + 125 ℃ Accuracy -25 ... + 125 ℃ |
Measurement range -25 ... + 125 ℃ Accuracy ± 0.5k ± 0.005 × | T | |
Measurement range -40 ... + 125 ℃ Accuracy@T = 0 ℃ ± 0.3 @T ≠ 0 ℃ ± 0.3k ± 0.005 × | T | T | |
Frequency 50%F.S. 1%of full scale 50%F.S. 2%of the measured values |
There is a flow rate, temperature sensor type | Select from voltage, current, pulse |
Media < + 125 ℃ Viper temperature -15 ... + 85 ℃ Save temperature -30 ... + 85 ℃ |
Click on the part number for more information about each product