High -precision / high -speed response / low flow turbine flow meter DML series-DML0.6
High -precision / high -speed response / low flow turbine flow meter DML series-Krone Co., Ltd.

High -precision / high -speed response / low flow turbine flow meter DML series
Krone Co., Ltd.


About This Product

■ Measure the small flow rate with high accuracy ・ Turbine flow sensor DML series is a turbine flow sensor that can measure the very small flow range of liquids and gas with high accuracy. ・ High -speed response and compact design can easily connect to piping by various connection types. ・ Measurement of fuel, refrigerant, lubricating oil, food and pharmaceuticals in the engine development ・ Surveillance / measurement of ultra -pure water in the R & D department ・ Can be used for fuel efficiency measurement of diesel fuel ■ Applications Aircraft -related, gas turbine, gasheat pump, etc. ■ Features ・ Calibration is performed by Trigasfi. TRIGASFI is a DAKKS certified organization for international MRA. ・ DAKKS calibration is proven by submission of DAKKS calibration certificate only. ・ TRIGASFI is one of the few calibration organizations that can be calibrated with actual viscosity and actual liquid under the ISO/IEC17025 certification standard.

  • Product

    High -precision / high -speed response / low flow turbine flow meter DML series




*Please note that we may not be able to accommodate sample requests.

5 Models of High -precision / high -speed response / low flow turbine flow meter DML series

Items marked with have different values ​​depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Diameter Expansion measurement range (gas) ML/min Expansion measurement range (liquid) ML/min Fluid viscosity K-FACTOR (gas) P/ML K-FACTOR (liquid) P/ML Measurement accuracy (gas) Measurement accuracy (liquid) Measurement range (gas) ML/min Measurement range (liquid) ML/min Operating temperature Response time Usage pressure
High -precision / high -speed response / low flow turbine flow meter DML series-Part Number-DML0.6

DML0.6

Available upon quote G 1/2 "female - Min.3.8
max.303
Calibrated with the same viscosity according to the terms of use. (Standard: 1.3 mm²/s) 170 211 Straight line: ± 0.60 % RD ( * 10: 1 range), ± 0.1 % RD (when linearse correction function)
Reproduction: ± 0.2 % RD
Straight line: ± 0.25 % RD ( * 10: 1 range), ± 0.1 % RD (when linearse correction function)
Reproduction: ± 0.1 % RD
min.42.5
max.425
min.7.57
max.75.7
By pickup 4ms or less MAX 40MPa (standard) * There is also an optional high -pressure model.
High -precision / high -speed response / low flow turbine flow meter DML series-Part Number-DML1.0

DML1.0

Available upon quote G 1/2 "female min.57
max.848
min.11
max.605
Calibrated with the same viscosity according to the terms of use. (Standard: 1.3 mm²/s) 85 119 Straight line: ± 0.60 % RD ( * 10: 1 range), ± 0.1 % RD (when linearse correction function)
Reproduction: ± 0.2 % RD
Straight line: ± 0.25 % RD ( * 10: 1 range), ± 0.1 % RD (when linearse correction function)
Reproduction: ± 0.1 % RD
min.70.8
max.708
Min.30.3
max.303
By pickup 4ms or less MAX 40MPa (standard) * There is also an optional high -pressure model.
High -precision / high -speed response / low flow turbine flow meter DML series-Part Number-DML2.0

DML2.0

Available upon quote G 1/2 "female min.99
Max.1,698
min.38
Max.1,514
Calibrated with the same viscosity according to the terms of use. (Standard: 1.3 mm²/s) 36 48 Straight line: ± 0.60 % RD ( * 10: 1 range), ± 0.1 % RD (when linearse correction function)
Reproduction: ± 0.2 % RD
Straight line: ± 0.25 % RD ( * 10: 1 range), ± 0.1 % RD (when linearse correction function)
Reproduction: ± 0.1 % RD
min.141.5
Max.1,415
min.94.6
max.946
By pickup 4ms or less MAX 40MPa (standard) * There is also an optional high -pressure model.
High -precision / high -speed response / low flow turbine flow meter DML series-Part Number-DML4.0

DML4.0

Available upon quote G 1/2 "female min.226
Max.5,663
min.76
Max.4,920
Calibrated with the same viscosity according to the terms of use. (Standard: 1.3 mm²/s) 14 15 Straight line: ± 0.60 % RD ( * 10: 1 range), ± 0.1 % RD (when linearse correction function)
Reproduction: ± 0.2 % RD
Straight line: ± 0.25 % RD ( * 10: 1 range), ± 0.1 % RD (when linearse correction function)
Reproduction: ± 0.1 % RD
min.339.8
Max.3,398
min.302.8
Max.3,028
By pickup 4ms or less MAX 40MPa (standard) * There is also an optional high -pressure model.
High -precision / high -speed response / low flow turbine flow meter DML series-Part Number-DML5.0

DML5.0

Available upon quote G 1/2 "female min.425
Max.8,495
min.189
Max.7,570
Calibrated with the same viscosity according to the terms of use. (Standard: 1.3 mm²/s) 8.5 9 Straight line: ± 0.60 % RD ( * 10: 1 range), ± 0.1 % RD (when linearse correction function)
Reproduction: ± 0.2 % RD
Straight line: ± 0.25 % RD ( * 10: 1 range), ± 0.1 % RD (when linearse correction function)
Reproduction: ± 0.1 % RD
min.566.3
Max.5,663
min.567.7
Max.5,677
By pickup 4ms or less MAX 40MPa (standard) * There is also an optional high -pressure model.

Click on the part number for more information about each product