Product
Multiple -channel -compatible thermal electron -temperature data logger TC101A seriesHandling Company
Krone Co., Ltd.Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Battery life | Battery used | Body material | Cold contact correction | External accuracy | External decomposition ability | External temperature range | Internal channel accuracy | Internal channel resolution | Internal channel temperature range | Measurement interval | Measurement start mode | Memory number | Number of external channels | Number of internal channels | Proofreading | Real -time measurement | Used environment humidity | Used environment temperature | data form | graph display | size | software | weight |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TC101A K-type |
Available upon quote | About 10 years | 3.6V lithium battery (possible with battery replacement users) | ABS resin | Self -working correction by internal channel | ± 0.5 ℃ | 0.1 ℃ | -260 ~+1,370 ° C | ± 0.25 ℃ | 0.1 ℃ | -40 ~+80 ℃ | Select once every four to 12 hours per second | Measurement starts with analysis software or measurement start setting can be set from up to 6 months after up to 6 months | 500,000 memory/ 1 channel | 1 | 1 |
Digital calibration is possible with analysis software Volonged day record date |
Date and time and temperature are recorded by connecting to a personal computer | 95%RH or less (without condensation) | -40 ~+80 ℃ | Record the temperature over the date and time. Various temperature units can be changed | Display from one graph to all graphs | 36 mm x 56 mm x 16 mm | Compatible with Windows XP SP3 | twenty four | |
TC101A J-type |
Available upon quote | About 10 years | 3.6V lithium battery (possible with battery replacement users) | ABS resin | Self -working correction by internal channel | ± 0.5 ℃ | 0.1 ℃ | -210 ~+ 760 ° C | ± 0.25 ℃ | 0.1 ℃ | -40 ~+80 ℃ | Select once every four to 12 hours per second | Measurement starts with analysis software or measurement start setting can be set from up to 6 months after up to 6 months | 500,000 memory/ 1 channel | 1 | 1 |
Digital calibration is possible with analysis software Volonged day record date |
Date and time and temperature are recorded by connecting to a personal computer | 95%RH or less (without condensation) | -40 ~+80 ℃ | Record the temperature over the date and time. Various temperature units can be changed | Display from one graph to all graphs | 36 mm x 56 mm x 16 mm | Compatible with Windows XP SP3 | twenty four | |
TC101A T-type |
Available upon quote | About 10 years | 3.6V lithium battery (possible with battery replacement users) | ABS resin | Self -working correction by internal channel | ± 0.5 ℃ | 0.1 ℃ | -260 ~+ 400 ℃ | ± 0.25 ℃ | 0.1 ℃ | -40 ~+80 ℃ | Select once every four to 12 hours per second | Measurement starts with analysis software or measurement start setting can be set from up to 6 months after up to 6 months | 500,000 memory/ 1 channel | 1 | 1 |
Digital calibration is possible with analysis software Volonged day record date |
Date and time and temperature are recorded by connecting to a personal computer | 95%RH or less (without condensation) | -40 ~+80 ℃ | Record the temperature over the date and time. Various temperature units can be changed | Display from one graph to all graphs | 36 mm x 56 mm x 16 mm | Compatible with Windows XP SP3 | twenty four | |
TC101A E-type |
Available upon quote | About 10 years | 3.6V lithium battery (possible with battery replacement users) | ABS resin | Self -working correction by internal channel | ± 0.5 ℃ | 0.1 ℃ | -260 ~+ 980 ° C | ± 0.25 ℃ | 0.1 ℃ | -40 ~+80 ℃ | Select once every four to 12 hours per second | Measurement starts with analysis software or measurement start setting can be set from up to 6 months after up to 6 months | 500,000 memory/ 1 channel | 1 | 1 |
Digital calibration is possible with analysis software Volonged day record date |
Date and time and temperature are recorded by connecting to a personal computer | 95%RH or less (without condensation) | -40 ~+80 ℃ | Record the temperature over the date and time. Various temperature units can be changed | Display from one graph to all graphs | 36 mm x 56 mm x 16 mm | Compatible with Windows XP SP3 | twenty four | |
TC101A R-type |
Available upon quote | About 10 years | 3.6V lithium battery (possible with battery replacement users) | ABS resin | Self -working correction by internal channel | ± 2.0 ℃ | 0.5 ℃ | -50 ~+ 1,760 ℃ | ± 0.25 ℃ | 0.1 ℃ | -40 ~+80 ℃ | Select once every four to 12 hours per second | Measurement starts with analysis software or measurement start setting can be set from up to 6 months after up to 6 months | 500,000 memory/ 1 channel | 1 | 1 |
Digital calibration is possible with analysis software Volonged day record date |
Date and time and temperature are recorded by connecting to a personal computer | 95%RH or less (without condensation) | -40 ~+80 ℃ | Record the temperature over the date and time. Various temperature units can be changed | Display from one graph to all graphs | 36 mm x 56 mm x 16 mm | Compatible with Windows XP SP3 | twenty four | |
TC101A S-type |
Available upon quote | About 10 years | 3.6V lithium battery (possible with battery replacement users) | ABS resin | Self -working correction by internal channel | ± 2.0 ℃ | 0.5 ℃ | -50 ~+ 1,760 ℃ | ± 0.25 ℃ | 0.1 ℃ | -40 ~+80 ℃ | Select once every four to 12 hours per second | Measurement starts with analysis software or measurement start setting can be set from up to 6 months after up to 6 months | 500,000 memory/ 1 channel | 1 | 1 |
Digital calibration is possible with analysis software Volonged day record date |
Date and time and temperature are recorded by connecting to a personal computer | 95%RH or less (without condensation) | -40 ~+80 ℃ | Record the temperature over the date and time. Various temperature units can be changed | Display from one graph to all graphs | 36 mm x 56 mm x 16 mm | Compatible with Windows XP SP3 | twenty four | |
TC101A B-type |
Available upon quote | About 10 years | 3.6V lithium battery (possible with battery replacement users) | ABS resin | Self -working correction by internal channel | ± 2.0 ℃ | 0.5 ℃ | -60 ~+ 1,820 ° C | ± 0.25 ℃ | 0.1 ℃ | -40 ~+80 ℃ | Select once every four to 12 hours per second | Measurement starts with analysis software or measurement start setting can be set from up to 6 months after up to 6 months | 500,000 memory/ 1 channel | 1 | 1 |
Digital calibration is possible with analysis software Volonged day record date |
Date and time and temperature are recorded by connecting to a personal computer | 95%RH or less (without condensation) | -40 ~+80 ℃ | Record the temperature over the date and time. Various temperature units can be changed | Display from one graph to all graphs | 36 mm x 56 mm x 16 mm | Compatible with Windows XP SP3 | twenty four | |
TC101A N-type |
Available upon quote | About 10 years | 3.6V lithium battery (possible with battery replacement users) | ABS resin | Self -working correction by internal channel | ± 0.5 ℃ | 0.1 ℃ | -260 ~+1,300 ° C | ± 0.25 ℃ | 0.1 ℃ | -40 ~+80 ℃ | Select once every four to 12 hours per second | Measurement starts with analysis software or measurement start setting can be set from up to 6 months after up to 6 months | 500,000 memory/ 1 channel | 1 | 1 |
Digital calibration is possible with analysis software Volonged day record date |
Date and time and temperature are recorded by connecting to a personal computer | 95%RH or less (without condensation) | -40 ~+80 ℃ | Record the temperature over the date and time. Various temperature units can be changed | Display from one graph to all graphs | 36 mm x 56 mm x 16 mm | Compatible with Windows XP SP3 | twenty four |
Click on the part number for more information about each product