Temperature data logger double sensor HITEMP140X2-FP series-HITEMP140 × 2-FP-6
Temperature data logger double sensor HITEMP140X2-FP series-Krone Co., Ltd.

Temperature data logger double sensor HITEMP140X2-FP series
Krone Co., Ltd.


About This Product

■ Overview HITEMP140 × 2-FP is a temperature data logger that can measure two places at the same time in a low-temperature environment from -40 to 140 ° C. Vial bottles, test pipes, and other small vials use Teflon flexible probes that are easy to handle, and high -voltage steam sterilizers (autoclaves (autoclaves), pharmaceutical manufacturing processes and medical equipment (autoclave). ) Assuming a sterilized validation within 121 ° C. ■ Characteristics of the main unit ・ Measurement temperature range: -60 ~+260 ° C ・ The probe code can be easily bent ・ Number of memory 32,767/channel ・ High accuracy of ± 0.1 ° C using a PT-100 sensor ・ Power -resistant waterproof structure IP68 ・ Download quickly data ・ Battery life and battery can be replaced by everyone ・ With ISO/IEC17025 calibration certificate ■ Compatible with strict standards in the medical field The temperature sensor used in HITEMP140 × 2-FP uses a platinum resistance, and the accuracy is ± 0.1 ° C to meet strict standards in the medical field. In addition, the logger body is small, and it is an IP68 compatible product designed to be used underwater. ■ Compatible with various applications The probe is about 150mm to about 1800mm, and you can select a probe suitable for various uses. When used in an environment that exceeds 140 ° C for the data logger itself, it can be used in a high temperature environment up to 250 ° C by installing a heat -resistant case. ■ Analysis software (free download) ・ The analysis software Madgetech4 allows you to download the latest version from the official manufacturer site for free. ・ The temperature data graph display, measurement time, and conversion function to Excel are implemented. ・ It is possible to automatically calculate the F0 value, which is the sterile index, as well as the maximum value, minimum, and average from the measurement result data. ■ Applications Autopraves, sterilized variation in high -pressure steam sterilizers, sterilized temperature control of retort, low -temperature sterilization of low -temperature sterilization

  • Product

    Temperature data logger double sensor HITEMP140X2-FP series




*Please note that we may not be able to accommodate sample requests.

6 Models of Temperature data logger double sensor HITEMP140X2-FP series

Items marked with have different values ​​depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Battery life Battery used Extended probe material Material Measurement accuracy Measurement interval Measurement start mode Measurement temperature range Memory number Proofreading Real -time measurement Temperature sensor Usage environment pressure Used environment humidity Used environment temperature data form graph display resolution size software weight
Temperature data logger double sensor HITEMP140X2-FP series-Part Number-HITEMP140 × 2-FP-6

HITEMP140 × 2-FP-6

Available upon quote About one year 3.6V lithium battery (possible with battery replacement users) SUS 316 / PFA coat SUS316 /PEEK ± 0.1 ° C (+20 ~+140 ° C range) Select once every second to 24 hours Measurement start with analysis software or measurement start setting can be set up after up to 18 months -60 ~+260 ° C 32,767 /Channel Digital calibration can be made by analysis software on the school correction day Date and time and temperature are recorded by connecting to a personal computer Shirokane resistor PT 100Ω 0.1379 (under vacuum) ~ 6,896 MBAR (low pressure) 100%RH (compatible with pressure -resistant waterproof IP68) -40 ~+140 ° C Record the temperature over the date and time. Various temperature units can be changed The same can be displayed from one graph to many graphs 0.01 ℃ φ3.2mm x length 152mm Compatible with Windows XP SP3 Approximately 110 g
Temperature data logger double sensor HITEMP140X2-FP series-Part Number-HITEMP140 × 2-FP-6/36

HITEMP140 × 2-FP-6/36

Available upon quote About one year 3.6V lithium battery (possible with battery replacement users) SUS 316 / PFA coat SUS316 /PEEK ± 0.1 ° C (+20 ~+140 ° C range) Select once every second to 24 hours Measurement start with analysis software or measurement start setting can be set up after up to 18 months -60 ~+260 ° C 32,767 /Channel Digital calibration can be made by analysis software on the school correction day Date and time and temperature are recorded by connecting to a personal computer Shirokane resistor PT 100Ω 0.1379 (under vacuum) ~ 6,896 MBAR (low pressure) 100%RH (compatible with pressure -resistant waterproof IP68) -40 ~+140 ° C Record the temperature over the date and time. Various temperature units can be changed The same can be displayed from one graph to many graphs 0.01 ℃ φ3.2mm x length 152mm Compatible with Windows XP SP3 Approximately 110 g
Temperature data logger double sensor HITEMP140X2-FP series-Part Number-HITEMP140 × 2-FP-12

HITEMP140 × 2-FP-12

Available upon quote About one year 3.6V lithium battery (possible with battery replacement users) SUS 316 / PFA coat SUS316 /PEEK ± 0.1 ° C (+20 ~+140 ° C range) Select once every second to 24 hours Measurement start with analysis software or measurement start setting can be set up after up to 18 months -60 ~+260 ° C 32,767 /Channel Digital calibration can be made by analysis software on the school correction day Date and time and temperature are recorded by connecting to a personal computer Shirokane resistor PT 100Ω 0.1379 (under vacuum) ~ 6,896 MBAR (low pressure) 100%RH (compatible with pressure -resistant waterproof IP68) -40 ~+140 ° C Record the temperature over the date and time. Various temperature units can be changed The same can be displayed from one graph to many graphs 0.01 ℃ φ3.2mm x Length 305mm Compatible with Windows XP SP3 Approximately 110 g
Temperature data logger double sensor HITEMP140X2-FP series-Part Number-HITEMP140 × 2-FP-24

HITEMP140 × 2-FP-24

Available upon quote About one year 3.6V lithium battery (possible with battery replacement users) SUS 316 / PFA coat SUS316 /PEEK ± 0.1 ° C (+20 ~+140 ° C range) Select once every second to 24 hours Measurement start with analysis software or measurement start setting can be set up after up to 18 months -60 ~+260 ° C 32,767 /Channel Digital calibration can be made by analysis software on the school correction day Date and time and temperature are recorded by connecting to a personal computer Shirokane resistor PT 100Ω 0.1379 (under vacuum) ~ 6,896 MBAR (low pressure) 100%RH (compatible with pressure -resistant waterproof IP68) -40 ~+140 ° C Record the temperature over the date and time. Various temperature units can be changed The same can be displayed from one graph to many graphs 0.01 ℃ φ3.2mm x Length 610mm Compatible with Windows XP SP3 Approximately 110 g
Temperature data logger double sensor HITEMP140X2-FP series-Part Number-HITEMP140 × 2-FP-36

HITEMP140 × 2-FP-36

Available upon quote About one year 3.6V lithium battery (possible with battery replacement users) SUS 316 / PFA coat SUS316 /PEEK ± 0.1 ° C (+20 ~+140 ° C range) Select once every second to 24 hours Measurement start with analysis software or measurement start setting can be set up after up to 18 months -60 ~+260 ° C 32,767 /Channel Digital calibration can be made by analysis software on the school correction day Date and time and temperature are recorded by connecting to a personal computer Shirokane resistor PT 100Ω 0.1379 (under vacuum) ~ 6,896 MBAR (low pressure) 100%RH (compatible with pressure -resistant waterproof IP68) -40 ~+140 ° C Record the temperature over the date and time. Various temperature units can be changed The same can be displayed from one graph to many graphs 0.01 ℃ φ3.2mm x length 914mm Compatible with Windows XP SP3 Approximately 110 g
Temperature data logger double sensor HITEMP140X2-FP series-Part Number-HITEMP140 × 2-FP-72

HITEMP140 × 2-FP-72

Available upon quote About one year 3.6V lithium battery (possible with battery replacement users) SUS 316 / PFA coat SUS316 /PEEK ± 0.1 ° C (+20 ~+140 ° C range) Select once every second to 24 hours Measurement start with analysis software or measurement start setting can be set up after up to 18 months -60 ~+260 ° C 32,767 /Channel Digital calibration can be made by analysis software on the school correction day Date and time and temperature are recorded by connecting to a personal computer Shirokane resistor PT 100Ω 0.1379 (under vacuum) ~ 6,896 MBAR (low pressure) 100%RH (compatible with pressure -resistant waterproof IP68) -40 ~+140 ° C Record the temperature over the date and time. Various temperature units can be changed The same can be displayed from one graph to many graphs 0.01 ℃ φ3.2mm x length 1829mm Compatible with Windows XP SP3 Approximately 110 g

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Krone Co., Ltd.


View more products of Krone Co., Ltd.

About Company Handling This Product

Krone Co., Ltd.

  • Japan
  • Since 1980

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree