Product
Temperature data logger double sensor HITEMP140X2-FP seriesHandling Company
Krone Co., Ltd.Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Battery life | Battery used | Extended probe material | Material | Measurement accuracy | Measurement interval | Measurement start mode | Measurement temperature range | Memory number | Proofreading | Real -time measurement | Temperature sensor | Usage environment pressure | Used environment humidity | Used environment temperature | data form | graph display | resolution | size | software | weight |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
HITEMP140 × 2-FP-6 |
Available upon quote | About one year | 3.6V lithium battery (possible with battery replacement users) | SUS 316 / PFA coat | SUS316 /PEEK | ± 0.1 ° C (+20 ~+140 ° C range) | Select once every second to 24 hours | Measurement start with analysis software or measurement start setting can be set up after up to 18 months | -60 ~+260 ° C | 32,767 /Channel | Digital calibration can be made by analysis software on the school correction day | Date and time and temperature are recorded by connecting to a personal computer | Shirokane resistor PT 100Ω | 0.1379 (under vacuum) ~ 6,896 MBAR (low pressure) | 100%RH (compatible with pressure -resistant waterproof IP68) | -40 ~+140 ° C | Record the temperature over the date and time. Various temperature units can be changed | The same can be displayed from one graph to many graphs | 0.01 ℃ | φ3.2mm x length 152mm | Compatible with Windows XP SP3 | Approximately 110 g | |
HITEMP140 × 2-FP-6/36 |
Available upon quote | About one year | 3.6V lithium battery (possible with battery replacement users) | SUS 316 / PFA coat | SUS316 /PEEK | ± 0.1 ° C (+20 ~+140 ° C range) | Select once every second to 24 hours | Measurement start with analysis software or measurement start setting can be set up after up to 18 months | -60 ~+260 ° C | 32,767 /Channel | Digital calibration can be made by analysis software on the school correction day | Date and time and temperature are recorded by connecting to a personal computer | Shirokane resistor PT 100Ω | 0.1379 (under vacuum) ~ 6,896 MBAR (low pressure) | 100%RH (compatible with pressure -resistant waterproof IP68) | -40 ~+140 ° C | Record the temperature over the date and time. Various temperature units can be changed | The same can be displayed from one graph to many graphs | 0.01 ℃ | φ3.2mm x length 152mm | Compatible with Windows XP SP3 | Approximately 110 g | |
HITEMP140 × 2-FP-12 |
Available upon quote | About one year | 3.6V lithium battery (possible with battery replacement users) | SUS 316 / PFA coat | SUS316 /PEEK | ± 0.1 ° C (+20 ~+140 ° C range) | Select once every second to 24 hours | Measurement start with analysis software or measurement start setting can be set up after up to 18 months | -60 ~+260 ° C | 32,767 /Channel | Digital calibration can be made by analysis software on the school correction day | Date and time and temperature are recorded by connecting to a personal computer | Shirokane resistor PT 100Ω | 0.1379 (under vacuum) ~ 6,896 MBAR (low pressure) | 100%RH (compatible with pressure -resistant waterproof IP68) | -40 ~+140 ° C | Record the temperature over the date and time. Various temperature units can be changed | The same can be displayed from one graph to many graphs | 0.01 ℃ | φ3.2mm x Length 305mm | Compatible with Windows XP SP3 | Approximately 110 g | |
HITEMP140 × 2-FP-24 |
Available upon quote | About one year | 3.6V lithium battery (possible with battery replacement users) | SUS 316 / PFA coat | SUS316 /PEEK | ± 0.1 ° C (+20 ~+140 ° C range) | Select once every second to 24 hours | Measurement start with analysis software or measurement start setting can be set up after up to 18 months | -60 ~+260 ° C | 32,767 /Channel | Digital calibration can be made by analysis software on the school correction day | Date and time and temperature are recorded by connecting to a personal computer | Shirokane resistor PT 100Ω | 0.1379 (under vacuum) ~ 6,896 MBAR (low pressure) | 100%RH (compatible with pressure -resistant waterproof IP68) | -40 ~+140 ° C | Record the temperature over the date and time. Various temperature units can be changed | The same can be displayed from one graph to many graphs | 0.01 ℃ | φ3.2mm x Length 610mm | Compatible with Windows XP SP3 | Approximately 110 g | |
HITEMP140 × 2-FP-36 |
Available upon quote | About one year | 3.6V lithium battery (possible with battery replacement users) | SUS 316 / PFA coat | SUS316 /PEEK | ± 0.1 ° C (+20 ~+140 ° C range) | Select once every second to 24 hours | Measurement start with analysis software or measurement start setting can be set up after up to 18 months | -60 ~+260 ° C | 32,767 /Channel | Digital calibration can be made by analysis software on the school correction day | Date and time and temperature are recorded by connecting to a personal computer | Shirokane resistor PT 100Ω | 0.1379 (under vacuum) ~ 6,896 MBAR (low pressure) | 100%RH (compatible with pressure -resistant waterproof IP68) | -40 ~+140 ° C | Record the temperature over the date and time. Various temperature units can be changed | The same can be displayed from one graph to many graphs | 0.01 ℃ | φ3.2mm x length 914mm | Compatible with Windows XP SP3 | Approximately 110 g | |
HITEMP140 × 2-FP-72 |
Available upon quote | About one year | 3.6V lithium battery (possible with battery replacement users) | SUS 316 / PFA coat | SUS316 /PEEK | ± 0.1 ° C (+20 ~+140 ° C range) | Select once every second to 24 hours | Measurement start with analysis software or measurement start setting can be set up after up to 18 months | -60 ~+260 ° C | 32,767 /Channel | Digital calibration can be made by analysis software on the school correction day | Date and time and temperature are recorded by connecting to a personal computer | Shirokane resistor PT 100Ω | 0.1379 (under vacuum) ~ 6,896 MBAR (low pressure) | 100%RH (compatible with pressure -resistant waterproof IP68) | -40 ~+140 ° C | Record the temperature over the date and time. Various temperature units can be changed | The same can be displayed from one graph to many graphs | 0.01 ℃ | φ3.2mm x length 1829mm | Compatible with Windows XP SP3 | Approximately 110 g |
Click on the part number for more information about each product