Product
Digital display thermal electricity temperature data logger TCTEMP2000 seriesHandling Company
Krone Co., Ltd.Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Battery life | Battery used | Body material | Cold contact correction | External accuracy | External decomposition ability | External temperature range | Internal channel proofreading accuracy | Internal channel temperature decomposition ability | Internal channel temperature range | Measurement interval | Measurement start mode | Memory number | Number of external channels | Number of internal channels | Proofreading | Real -time measurement | Used environment humidity | Used environment temperature | Waterproof structure | data form | graph display | size | software |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TCTEMP2000 K-type |
Available upon quote | About 1 year (in 1 minute interval) | 9V lithium battery (possible with battery replacement users) | Slow -oxide aluminum | Self -working correction by internal channel | ± 0.5 ℃ | 0.1 ℃ | -260 ~+1,370 ° C | ± 0.5 ℃ | 0.1 ℃ | -20 ~+60 ℃ | Select once every 2 seconds to 24 hours | Measurement starts with analysis software or measurement start setting can be set from up to 6 months after up to 6 months | 131,071 Memory/ 1 Channel | 1 | 1 |
Digital calibration is possible with analysis software Volonged day record date |
Date and time and temperature are recorded by connecting to a personal computer | 0 to 95%RH or less (no condensation) | -40 ~+80 ℃ | IP68 (water depth 42 m resistant pressure) | Record the temperature over the date and time. Various temperature units can be changed | Display from one graph to all graphs | 122 x 84 x 32mm | Windows 7, 8, 10 compatible | |
TCTEMP2000 J-type |
Available upon quote | About 1 year (in 1 minute interval) | 9V lithium battery (possible with battery replacement users) | Slow -oxide aluminum | Self -working correction by internal channel | ± 0.5 ℃ | 0.1 ℃ | -210 ~+ 760 ° C | ± 0.5 ℃ | 0.1 ℃ | -20 ~+60 ℃ | Select once every 2 seconds to 24 hours | Measurement starts with analysis software or measurement start setting can be set from up to 6 months after up to 6 months | 131,071 Memory/ 1 Channel | 1 | 1 |
Digital calibration is possible with analysis software Volonged day record date |
Date and time and temperature are recorded by connecting to a personal computer | 0 to 95%RH or less (no condensation) | -40 ~+80 ℃ | IP68 (water depth 42 m resistant pressure) | Record the temperature over the date and time. Various temperature units can be changed | Display from one graph to all graphs | 122 x 84 x 32mm | Windows 7, 8, 10 compatible | |
TCTEMP2000 T-type |
Available upon quote | About 1 year (in 1 minute interval) | 9V lithium battery (possible with battery replacement users) | Slow -oxide aluminum | Self -working correction by internal channel | ± 0.5 ℃ | 0.1 ℃ | -260 ~+ 400 ℃ | ± 0.5 ℃ | 0.1 ℃ | -20 ~+60 ℃ | Select once every 2 seconds to 24 hours | Measurement starts with analysis software or measurement start setting can be set from up to 6 months after up to 6 months | 131,071 Memory/ 1 Channel | 1 | 1 |
Digital calibration is possible with analysis software Volonged day record date |
Date and time and temperature are recorded by connecting to a personal computer | 0 to 95%RH or less (no condensation) | -40 ~+80 ℃ | IP68 (water depth 42 m resistant pressure) | Record the temperature over the date and time. Various temperature units can be changed | Display from one graph to all graphs | 122 x 84 x 32mm | Windows 7, 8, 10 compatible | |
TCTEMP2000 E-type |
Available upon quote | About 1 year (in 1 minute interval) | 9V lithium battery (possible with battery replacement users) | Slow -oxide aluminum | Self -working correction by internal channel | ± 0.5 ℃ | 0.1 ℃ | -260 ~+ 980 ° C | ± 0.5 ℃ | 0.1 ℃ | -20 ~+60 ℃ | Select once every 2 seconds to 24 hours | Measurement starts with analysis software or measurement start setting can be set from up to 6 months after up to 6 months | 131,071 Memory/ 1 Channel | 1 | 1 |
Digital calibration is possible with analysis software Volonged day record date |
Date and time and temperature are recorded by connecting to a personal computer | 0 to 95%RH or less (no condensation) | -40 ~+80 ℃ | IP68 (water depth 42 m resistant pressure) | Record the temperature over the date and time. Various temperature units can be changed | Display from one graph to all graphs | 122 x 84 x 32mm | Windows 7, 8, 10 compatible | |
TCTEMP2000 R-type |
Available upon quote | About 1 year (in 1 minute interval) | 9V lithium battery (possible with battery replacement users) | Slow -oxide aluminum | Self -working correction by internal channel | ± 2.0 ℃ | 0.5 ℃ | -50 ~+ 1,760 ℃ | ± 0.5 ℃ | 0.1 ℃ | -20 ~+60 ℃ | Select once every 2 seconds to 24 hours | Measurement starts with analysis software or measurement start setting can be set from up to 6 months after up to 6 months | 131,071 Memory/ 1 Channel | 1 | 1 |
Digital calibration is possible with analysis software Volonged day record date |
Date and time and temperature are recorded by connecting to a personal computer | 0 to 95%RH or less (no condensation) | -40 ~+80 ℃ | IP68 (water depth 42 m resistant pressure) | Record the temperature over the date and time. Various temperature units can be changed | Display from one graph to all graphs | 122 x 84 x 32mm | Windows 7, 8, 10 compatible | |
TCTEMP2000 S-type |
Available upon quote | About 1 year (in 1 minute interval) | 9V lithium battery (possible with battery replacement users) | Slow -oxide aluminum | Self -working correction by internal channel | ± 2.0 ℃ | 0.5 ℃ | -50 ~+ 1,760 ℃ | ± 0.5 ℃ | 0.1 ℃ | -20 ~+60 ℃ | Select once every 2 seconds to 24 hours | Measurement starts with analysis software or measurement start setting can be set from up to 6 months after up to 6 months | 131,071 Memory/ 1 Channel | 1 | 1 |
Digital calibration is possible with analysis software Volonged day record date |
Date and time and temperature are recorded by connecting to a personal computer | 0 to 95%RH or less (no condensation) | -40 ~+80 ℃ | IP68 (water depth 42 m resistant pressure) | Record the temperature over the date and time. Various temperature units can be changed | Display from one graph to all graphs | 122 x 84 x 32mm | Windows 7, 8, 10 compatible | |
TCTEMP2000 B-type |
Available upon quote | About 1 year (in 1 minute interval) | 9V lithium battery (possible with battery replacement users) | Slow -oxide aluminum | Self -working correction by internal channel | ± 2.0 ℃ | 0.5 ℃ | -60 ~+ 1,820 ° C | ± 0.5 ℃ | 0.1 ℃ | -20 ~+60 ℃ | Select once every 2 seconds to 24 hours | Measurement starts with analysis software or measurement start setting can be set from up to 6 months after up to 6 months | 131,071 Memory/ 1 Channel | 1 | 1 |
Digital calibration is possible with analysis software Volonged day record date |
Date and time and temperature are recorded by connecting to a personal computer | 0 to 95%RH or less (no condensation) | -40 ~+80 ℃ | IP68 (water depth 42 m resistant pressure) | Record the temperature over the date and time. Various temperature units can be changed | Display from one graph to all graphs | 122 x 84 x 32mm | Windows 7, 8, 10 compatible | |
TCTEMP2000 N-type |
Available upon quote | About 1 year (in 1 minute interval) | 9V lithium battery (possible with battery replacement users) | Slow -oxide aluminum | Self -working correction by internal channel | ± 0.5 ℃ | 0.1 ℃ | -260 ~+1,300 ° C | ± 0.5 ℃ | 0.1 ℃ | -20 ~+60 ℃ | Select once every 2 seconds to 24 hours | Measurement starts with analysis software or measurement start setting can be set from up to 6 months after up to 6 months | 131,071 Memory/ 1 Channel | 1 | 1 |
Digital calibration is possible with analysis software Volonged day record date |
Date and time and temperature are recorded by connecting to a personal computer | 0 to 95%RH or less (no condensation) | -40 ~+80 ℃ | IP68 (water depth 42 m resistant pressure) | Record the temperature over the date and time. Various temperature units can be changed | Display from one graph to all graphs | 122 x 84 x 32mm | Windows 7, 8, 10 compatible |
Click on the part number for more information about each product