Ultrasonic flow meter for clamp -on tubes SONOFLOW co55/XXX (H) v2.0-Co55/035 v2.0
Ultrasonic flow meter for clamp -on tubes SONOFLOW co55/XXX (H) v2.0-Krone Co., Ltd.

Ultrasonic flow meter for clamp -on tubes SONOFLOW co55/XXX (H) v2.0
Krone Co., Ltd.


About This Product

SONOFLOW® is a sensor that can measure the flow rate from outside the tube without the media contact. We support various applications in fields with strict hygiene standards such as medical technology, biotechnology, pharmaceutical, chemistry, and semiconductor industries, etc., with analog output, frequency output, and switching output. In addition, the RS-485 communication (SONOTEC protocol; Modbus® by software settings) realizes up to 12 sensors in a harsh environment. ■ Applications Measurement of flow rate of artificial cardiopulmonary and dialysis devices, etc. * There are other model numbers.

  • Product

    Ultrasonic flow meter for clamp -on tubes SONOFLOW co55/XXX (H) v2.0




*Please note that we may not be able to accommodate sample requests.

10 Models of Ultrasonic flow meter for clamp -on tubes SONOFLOW co55/XXX (H) v2.0

Items marked with have different values ​​depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Applicable tube outer diameter x inner diameter (mm) Body material Calibration fluid Current consumption current Digital input Dimension CH X CW (mm) Dimension L X W X H (HWH) (mm) Flow range (ML/Min) Fluid temperature/environmental temperature Measured fluid Measurement accuracy Output connector Output signal Power-supply voltage Protection grade option storage temperature terms of use weight
Ultrasonic flow meter for clamp -on tubes SONOFLOW co55/XXX (H) v2.0-Part Number-Co55/035 v2.0

Co55/035 v2.0

Available upon quote 4.0 x 3.0 Measurement unit: PMMA
Housing: Aluminum (gray /red) * Options: Stainless steel, plastic
Water (23 ± 2 ℃)
* Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request.
Up to 50 ma Free configuration: zero point calibration and administration start signal (MAX 30V) □ 3.5 44 x 44 x 28 300 ~ 3,000 0 to 60 ° C Water, transparent liquid ± 2 % RD 8-pin M12 connector (din en 61076-2-101: 2012) 0/4-20 MA analog output
Frequency output: 0 ~ 20 kHz
RS-485 Communication (SONOTEC protocol, option MODBUS®)
Switching output: pnp/npn/push-pull
12 ~ 30VDC IP65 Sensor cable 2 meters or 5m
Calibration certificate
SONOFLOW C3 software
-20 ~ 70 ° C Tube material: PVC, silicon, PTFE, PFA, FEP, TPE, Tigon, PE
Tube outer diameter: 4-35 mm
120
Ultrasonic flow meter for clamp -on tubes SONOFLOW co55/XXX (H) v2.0-Part Number-Co55/044 v2.0

Co55/044 v2.0

Available upon quote 5.0 x 3.0 Measurement unit: PMMA
Housing: Aluminum (gray /red) * Options: Stainless steel, plastic
Water (23 ± 2 ℃)
* Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request.
Up to 50 ma Free configuration: zero point calibration and administration start signal (MAX 30V) □ 4.4 44 x 44 x 30 500 ~ 5,000 0 to 60 ° C Water, transparent liquid ± 2 % RD 8-pin M12 connector (din en 61076-2-101: 2012) 0/4-20 MA analog output
Frequency output: 0 ~ 20 kHz
RS-485 Communication (SONOTEC protocol, option MODBUS®)
Switching output: pnp/npn/push-pull
12 ~ 30VDC IP65 Sensor cable 2 meters or 5m
Calibration certificate
SONOFLOW C3 software
-20 ~ 70 ° C Tube material: PVC, silicon, PTFE, PFA, FEP, TPE, Tigon, PE
Tube outer diameter: 4-35 mm
125
Ultrasonic flow meter for clamp -on tubes SONOFLOW co55/XXX (H) v2.0-Part Number-Co55/060 v2.0

Co55/060 v2.0

Available upon quote 7.0 x 5.0 Measurement unit: PMMA
Housing: Aluminum (gray /red) * Options: Stainless steel, plastic
Water (23 ± 2 ℃)
* Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request.
Up to 50 ma Free configuration: zero point calibration and administration start signal (MAX 30V) □ 6.0 44 x 44 x 32 600 ~ 6,000 0 to 60 ° C Water, transparent liquid ± 2 % RD 8-pin M12 connector (din en 61076-2-101: 2012) 0/4-20 MA analog output
Frequency output: 0 ~ 20 kHz
RS-485 Communication (SONOTEC protocol, option MODBUS®)
Switching output: pnp/npn/push-pull
12 ~ 30VDC IP65 Sensor cable 2 meters or 5m
Calibration certificate
SONOFLOW C3 software
-20 ~ 70 ° C Tube material: PVC, silicon, PTFE, PFA, FEP, TPE, Tigon, PE
Tube outer diameter: 4-35 mm
130
Ultrasonic flow meter for clamp -on tubes SONOFLOW co55/XXX (H) v2.0-Part Number-Co55/080 v2.0

Co55/080 v2.0

Available upon quote 9.0 x 6.0 Measurement unit: PMMA
Housing: Aluminum (gray /red) * Options: Stainless steel, plastic
Water (23 ± 2 ℃)
* Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request.
Up to 50 ma Free configuration: zero point calibration and administration start signal (MAX 30V) □ 8.0 44 x 44 x 34 800 ~ 8,000 0 to 60 ° C Water, transparent liquid ± 2 % RD 8-pin M12 connector (din en 61076-2-101: 2012) 0/4-20 MA analog output
Frequency output: 0 ~ 20 kHz
RS-485 Communication (SONOTEC protocol, option MODBUS®)
Switching output: pnp/npn/push-pull
12 ~ 30VDC IP65 Sensor cable 2 meters or 5m
Calibration certificate
SONOFLOW C3 software
-20 ~ 70 ° C Tube material: PVC, silicon, PTFE, PFA, FEP, TPE, Tigon, PE
Tube outer diameter: 4-35 mm
135
Ultrasonic flow meter for clamp -on tubes SONOFLOW co55/XXX (H) v2.0-Part Number-Co55/100 v2.0

Co55/100 v2.0

Available upon quote 12.0 x 9.0 Measurement unit: PMMA
Housing: Aluminum (gray /red) * Options: Stainless steel, plastic
Water (23 ± 2 ℃)
* Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request.
Up to 50 ma Free configuration: zero point calibration and administration start signal (MAX 30V) □ 10.0 44 x 44 x 35 1,000-10,000 0 to 60 ° C Water, transparent liquid ± 2 % RD 8-pin M12 connector (din en 61076-2-101: 2012) 0/4-20 MA analog output
Frequency output: 0 ~ 20 kHz
RS-485 Communication (SONOTEC protocol, option MODBUS®)
Switching output: pnp/npn/push-pull
12 ~ 30VDC IP65 Sensor cable 2 meters or 5m
Calibration certificate
SONOFLOW C3 software
-20 ~ 70 ° C Tube material: PVC, silicon, PTFE, PFA, FEP, TPE, Tigon, PE
Tube outer diameter: 4-35 mm
138
Ultrasonic flow meter for clamp -on tubes SONOFLOW co55/XXX (H) v2.0-Part Number-Co55/120 V2.0

Co55/120 V2.0

Available upon quote 14.0 x 10.0 Measurement unit: PMMA
Housing: Aluminum (gray /red) * Options: Stainless steel, plastic
Water (23 ± 2 ℃)
* Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request.
Up to 50 ma Free configuration: zero point calibration and administration start signal (MAX 30V) □ 12.0 44 x 44 x 36 1,200 ~ 12,000 0 to 60 ° C Water, transparent liquid ± 2 % RD 8-pin M12 connector (din en 61076-2-101: 2012) 0/4-20 MA analog output
Frequency output: 0 ~ 20 kHz
RS-485 Communication (SONOTEC protocol, option MODBUS®)
Switching output: pnp/npn/push-pull
12 ~ 30VDC IP65 Sensor cable 2 meters or 5m
Calibration certificate
SONOFLOW C3 software
-20 ~ 70 ° C Tube material: PVC, silicon, PTFE, PFA, FEP, TPE, Tigon, PE
Tube outer diameter: 4-35 mm
140
Ultrasonic flow meter for clamp -on tubes SONOFLOW co55/XXX (H) v2.0-Part Number-Co55/140 v2.0

Co55/140 v2.0

Available upon quote 16.0 x 12.0 Measurement unit: PMMA
Housing: Aluminum (gray /red) * Options: Stainless steel, plastic
Water (23 ± 2 ℃)
* Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request.
Up to 50 ma Free configuration: zero point calibration and administration start signal (MAX 30V) □ 14.0 44 x 44 x 38 1,400 ~ 14,000 0 to 60 ° C Water, transparent liquid ± 2 % RD 8-pin M12 connector (din en 61076-2-101: 2012) 0/4-20 MA analog output
Frequency output: 0 ~ 20 kHz
RS-485 Communication (SONOTEC protocol, option MODBUS®)
Switching output: pnp/npn/push-pull
12 ~ 30VDC IP65 Sensor cable 2 meters or 5m
Calibration certificate
SONOFLOW C3 software
-20 ~ 70 ° C Tube material: PVC, silicon, PTFE, PFA, FEP, TPE, Tigon, PE
Tube outer diameter: 4-35 mm
145
Ultrasonic flow meter for clamp -on tubes SONOFLOW co55/XXX (H) v2.0-Part Number-Co55/160 v2.0

Co55/160 v2.0

Available upon quote 19.0 x 14.0 Measurement unit: PMMA
Housing: Aluminum (gray /red) * Options: Stainless steel, plastic
Water (23 ± 2 ℃)
* Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request.
Up to 50 ma Free configuration: zero point calibration and administration start signal (MAX 30V) □ 16.0 44 x 44 x 40 1,800 ~ 18,000 0 to 60 ° C Water, transparent liquid ± 2 % RD 8-pin M12 connector (din en 61076-2-101: 2012) 0/4-20 MA analog output
Frequency output: 0 ~ 20 kHz
RS-485 Communication (SONOTEC protocol, option MODBUS®)
Switching output: pnp/npn/push-pull
12 ~ 30VDC IP65 Sensor cable 2 meters or 5m
Calibration certificate
SONOFLOW C3 software
-20 ~ 70 ° C Tube material: PVC, silicon, PTFE, PFA, FEP, TPE, Tigon, PE
Tube outer diameter: 4-35 mm
150
Ultrasonic flow meter for clamp -on tubes SONOFLOW co55/XXX (H) v2.0-Part Number-Co55/190 v2.0

Co55/190 v2.0

Available upon quote 22.0 x 16.0 Measurement unit: PMMA
Housing: Aluminum (gray /red) * Options: Stainless steel, plastic
Water (23 ± 2 ℃)
* Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request.
Up to 50 ma Free configuration: zero point calibration and administration start signal (MAX 30V) □ 19.0 66 x 66 x 48 4,000 to 40,000 0 to 60 ° C Water, transparent liquid ± 2 % RD 8-pin M12 connector (din en 61076-2-101: 2012) 0/4-20 MA analog output
Frequency output: 0 ~ 20 kHz
RS-485 Communication (SONOTEC protocol, option MODBUS®)
Switching output: pnp/npn/push-pull
12 ~ 30VDC IP65 Sensor cable 2 meters or 5m
Calibration certificate
SONOFLOW C3 software
-20 ~ 70 ° C Tube material: PVC, silicon, PTFE, PFA, FEP, TPE, Tigon, PE
Tube outer diameter: 4-35 mm
380
Ultrasonic flow meter for clamp -on tubes SONOFLOW co55/XXX (H) v2.0-Part Number-Co55/230H v2.0

Co55/230H v2.0

Available upon quote 25.4 x 15.9 Measurement unit: PMMA
Housing: Aluminum (gray /red) * Options: Stainless steel, plastic
Water (23 ± 2 ℃)
* Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request.
Up to 50 ma Free configuration: zero point calibration and administration start signal (MAX 30V) □ 23.0 66 x 75 x 51 (72) 5,000 ~ 50,000 0 to 60 ° C Water, transparent liquid ± 2 % RD 8-pin M12 connector (din en 61076-2-101: 2012) 0/4-20 MA analog output
Frequency output: 0 ~ 20 kHz
RS-485 Communication (SONOTEC protocol, option MODBUS®)
Switching output: pnp/npn/push-pull
12 ~ 30VDC IP65 Sensor cable 2 meters or 5m
Calibration certificate
SONOFLOW C3 software
-20 ~ 70 ° C Tube material: PVC, silicon, PTFE, PFA, FEP, TPE, Tigon, PE
Tube outer diameter: 4-35 mm
510

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Krone Co., Ltd.


View more products of Krone Co., Ltd.

About Company Handling This Product

Krone Co., Ltd.

  • Japan
  • Since 1980

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree