Product
Ultrasonic flow meter for clamp -on tubes SONOFLOW co55/XXX (H) v2.0Handling Company
Krone Co., Ltd.Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Applicable tube outer diameter x inner diameter (mm) | Body material | Calibration fluid | Current consumption current | Digital input | Dimension CH X CW (mm) | Dimension L X W X H (HWH) (mm) | Flow range (ML/Min) | Fluid temperature/environmental temperature | Measured fluid | Measurement accuracy | Output connector | Output signal | Power-supply voltage | Protection grade | option | storage temperature | terms of use | weight |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Co55/035 v2.0 |
Available upon quote | 4.0 x 3.0 |
Measurement unit: PMMA Housing: Aluminum (gray /red) * Options: Stainless steel, plastic |
Water (23 ± 2 ℃) * Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request. |
Up to 50 ma | Free configuration: zero point calibration and administration start signal (MAX 30V) | □ 3.5 | 44 x 44 x 28 | 300 ~ 3,000 | 0 to 60 ° C | Water, transparent liquid | ± 2 % RD | 8-pin M12 connector (din en 61076-2-101: 2012) |
0/4-20 MA analog output Frequency output: 0 ~ 20 kHz RS-485 Communication (SONOTEC protocol, option MODBUS®) Switching output: pnp/npn/push-pull |
12 ~ 30VDC | IP65 |
Sensor cable 2 meters or 5m Calibration certificate SONOFLOW C3 software |
-20 ~ 70 ° C |
Tube material: PVC, silicon, PTFE, PFA, FEP, TPE, Tigon, PE Tube outer diameter: 4-35 mm |
120 | |
Co55/044 v2.0 |
Available upon quote | 5.0 x 3.0 |
Measurement unit: PMMA Housing: Aluminum (gray /red) * Options: Stainless steel, plastic |
Water (23 ± 2 ℃) * Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request. |
Up to 50 ma | Free configuration: zero point calibration and administration start signal (MAX 30V) | □ 4.4 | 44 x 44 x 30 | 500 ~ 5,000 | 0 to 60 ° C | Water, transparent liquid | ± 2 % RD | 8-pin M12 connector (din en 61076-2-101: 2012) |
0/4-20 MA analog output Frequency output: 0 ~ 20 kHz RS-485 Communication (SONOTEC protocol, option MODBUS®) Switching output: pnp/npn/push-pull |
12 ~ 30VDC | IP65 |
Sensor cable 2 meters or 5m Calibration certificate SONOFLOW C3 software |
-20 ~ 70 ° C |
Tube material: PVC, silicon, PTFE, PFA, FEP, TPE, Tigon, PE Tube outer diameter: 4-35 mm |
125 | |
Co55/060 v2.0 |
Available upon quote | 7.0 x 5.0 |
Measurement unit: PMMA Housing: Aluminum (gray /red) * Options: Stainless steel, plastic |
Water (23 ± 2 ℃) * Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request. |
Up to 50 ma | Free configuration: zero point calibration and administration start signal (MAX 30V) | □ 6.0 | 44 x 44 x 32 | 600 ~ 6,000 | 0 to 60 ° C | Water, transparent liquid | ± 2 % RD | 8-pin M12 connector (din en 61076-2-101: 2012) |
0/4-20 MA analog output Frequency output: 0 ~ 20 kHz RS-485 Communication (SONOTEC protocol, option MODBUS®) Switching output: pnp/npn/push-pull |
12 ~ 30VDC | IP65 |
Sensor cable 2 meters or 5m Calibration certificate SONOFLOW C3 software |
-20 ~ 70 ° C |
Tube material: PVC, silicon, PTFE, PFA, FEP, TPE, Tigon, PE Tube outer diameter: 4-35 mm |
130 | |
Co55/080 v2.0 |
Available upon quote | 9.0 x 6.0 |
Measurement unit: PMMA Housing: Aluminum (gray /red) * Options: Stainless steel, plastic |
Water (23 ± 2 ℃) * Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request. |
Up to 50 ma | Free configuration: zero point calibration and administration start signal (MAX 30V) | □ 8.0 | 44 x 44 x 34 | 800 ~ 8,000 | 0 to 60 ° C | Water, transparent liquid | ± 2 % RD | 8-pin M12 connector (din en 61076-2-101: 2012) |
0/4-20 MA analog output Frequency output: 0 ~ 20 kHz RS-485 Communication (SONOTEC protocol, option MODBUS®) Switching output: pnp/npn/push-pull |
12 ~ 30VDC | IP65 |
Sensor cable 2 meters or 5m Calibration certificate SONOFLOW C3 software |
-20 ~ 70 ° C |
Tube material: PVC, silicon, PTFE, PFA, FEP, TPE, Tigon, PE Tube outer diameter: 4-35 mm |
135 | |
Co55/100 v2.0 |
Available upon quote | 12.0 x 9.0 |
Measurement unit: PMMA Housing: Aluminum (gray /red) * Options: Stainless steel, plastic |
Water (23 ± 2 ℃) * Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request. |
Up to 50 ma | Free configuration: zero point calibration and administration start signal (MAX 30V) | □ 10.0 | 44 x 44 x 35 | 1,000-10,000 | 0 to 60 ° C | Water, transparent liquid | ± 2 % RD | 8-pin M12 connector (din en 61076-2-101: 2012) |
0/4-20 MA analog output Frequency output: 0 ~ 20 kHz RS-485 Communication (SONOTEC protocol, option MODBUS®) Switching output: pnp/npn/push-pull |
12 ~ 30VDC | IP65 |
Sensor cable 2 meters or 5m Calibration certificate SONOFLOW C3 software |
-20 ~ 70 ° C |
Tube material: PVC, silicon, PTFE, PFA, FEP, TPE, Tigon, PE Tube outer diameter: 4-35 mm |
138 | |
Co55/120 V2.0 |
Available upon quote | 14.0 x 10.0 |
Measurement unit: PMMA Housing: Aluminum (gray /red) * Options: Stainless steel, plastic |
Water (23 ± 2 ℃) * Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request. |
Up to 50 ma | Free configuration: zero point calibration and administration start signal (MAX 30V) | □ 12.0 | 44 x 44 x 36 | 1,200 ~ 12,000 | 0 to 60 ° C | Water, transparent liquid | ± 2 % RD | 8-pin M12 connector (din en 61076-2-101: 2012) |
0/4-20 MA analog output Frequency output: 0 ~ 20 kHz RS-485 Communication (SONOTEC protocol, option MODBUS®) Switching output: pnp/npn/push-pull |
12 ~ 30VDC | IP65 |
Sensor cable 2 meters or 5m Calibration certificate SONOFLOW C3 software |
-20 ~ 70 ° C |
Tube material: PVC, silicon, PTFE, PFA, FEP, TPE, Tigon, PE Tube outer diameter: 4-35 mm |
140 | |
Co55/140 v2.0 |
Available upon quote | 16.0 x 12.0 |
Measurement unit: PMMA Housing: Aluminum (gray /red) * Options: Stainless steel, plastic |
Water (23 ± 2 ℃) * Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request. |
Up to 50 ma | Free configuration: zero point calibration and administration start signal (MAX 30V) | □ 14.0 | 44 x 44 x 38 | 1,400 ~ 14,000 | 0 to 60 ° C | Water, transparent liquid | ± 2 % RD | 8-pin M12 connector (din en 61076-2-101: 2012) |
0/4-20 MA analog output Frequency output: 0 ~ 20 kHz RS-485 Communication (SONOTEC protocol, option MODBUS®) Switching output: pnp/npn/push-pull |
12 ~ 30VDC | IP65 |
Sensor cable 2 meters or 5m Calibration certificate SONOFLOW C3 software |
-20 ~ 70 ° C |
Tube material: PVC, silicon, PTFE, PFA, FEP, TPE, Tigon, PE Tube outer diameter: 4-35 mm |
145 | |
Co55/160 v2.0 |
Available upon quote | 19.0 x 14.0 |
Measurement unit: PMMA Housing: Aluminum (gray /red) * Options: Stainless steel, plastic |
Water (23 ± 2 ℃) * Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request. |
Up to 50 ma | Free configuration: zero point calibration and administration start signal (MAX 30V) | □ 16.0 | 44 x 44 x 40 | 1,800 ~ 18,000 | 0 to 60 ° C | Water, transparent liquid | ± 2 % RD | 8-pin M12 connector (din en 61076-2-101: 2012) |
0/4-20 MA analog output Frequency output: 0 ~ 20 kHz RS-485 Communication (SONOTEC protocol, option MODBUS®) Switching output: pnp/npn/push-pull |
12 ~ 30VDC | IP65 |
Sensor cable 2 meters or 5m Calibration certificate SONOFLOW C3 software |
-20 ~ 70 ° C |
Tube material: PVC, silicon, PTFE, PFA, FEP, TPE, Tigon, PE Tube outer diameter: 4-35 mm |
150 | |
Co55/190 v2.0 |
Available upon quote | 22.0 x 16.0 |
Measurement unit: PMMA Housing: Aluminum (gray /red) * Options: Stainless steel, plastic |
Water (23 ± 2 ℃) * Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request. |
Up to 50 ma | Free configuration: zero point calibration and administration start signal (MAX 30V) | □ 19.0 | 66 x 66 x 48 | 4,000 to 40,000 | 0 to 60 ° C | Water, transparent liquid | ± 2 % RD | 8-pin M12 connector (din en 61076-2-101: 2012) |
0/4-20 MA analog output Frequency output: 0 ~ 20 kHz RS-485 Communication (SONOTEC protocol, option MODBUS®) Switching output: pnp/npn/push-pull |
12 ~ 30VDC | IP65 |
Sensor cable 2 meters or 5m Calibration certificate SONOFLOW C3 software |
-20 ~ 70 ° C |
Tube material: PVC, silicon, PTFE, PFA, FEP, TPE, Tigon, PE Tube outer diameter: 4-35 mm |
380 | |
Co55/230H v2.0 |
Available upon quote | 25.4 x 15.9 |
Measurement unit: PMMA Housing: Aluminum (gray /red) * Options: Stainless steel, plastic |
Water (23 ± 2 ℃) * Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request. |
Up to 50 ma | Free configuration: zero point calibration and administration start signal (MAX 30V) | □ 23.0 | 66 x 75 x 51 (72) | 5,000 ~ 50,000 | 0 to 60 ° C | Water, transparent liquid | ± 2 % RD | 8-pin M12 connector (din en 61076-2-101: 2012) |
0/4-20 MA analog output Frequency output: 0 ~ 20 kHz RS-485 Communication (SONOTEC protocol, option MODBUS®) Switching output: pnp/npn/push-pull |
12 ~ 30VDC | IP65 |
Sensor cable 2 meters or 5m Calibration certificate SONOFLOW C3 software |
-20 ~ 70 ° C |
Tube material: PVC, silicon, PTFE, PFA, FEP, TPE, Tigon, PE Tube outer diameter: 4-35 mm |
510 |
Click on the part number for more information about each product