Price (excluding tax)
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Diameter
Expansion measurement range (liquid) ML/min
Fluid viscosity
K-FACTOR (gas) P/ML
K-FACTOR (liquid) P/ML
Measurement accuracy (gas)
Measurement accuracy (liquid)
Measurement range (gas) ML/min
Measurement range (liquid) ML/min
Operating temperature
Response time
Usage pressure
Expansion measurement range (gas) ML/min
Part Number
DML0.6Handling Company
Krone Co., Ltd.Items marked with have different values depending on the model number.
Product Image | Price (excluding tax) | Diameter | Expansion measurement range (liquid) ML/min | Fluid viscosity | K-FACTOR (gas) P/ML | K-FACTOR (liquid) P/ML | Measurement accuracy (gas) | Measurement accuracy (liquid) | Measurement range (gas) ML/min | Measurement range (liquid) ML/min | Operating temperature | Response time | Usage pressure |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Available upon quote | G 1/2 "female | Min.3.8 max.303 | Calibrated with the same viscosity according to the terms of use. (Standard: 1.3 mm²/s) | 170 | 211 | Straight line: ± 0.60 % RD ( * 10: 1 range), ± 0.1 % RD (when linearse correction function) Reproduction: ± 0.2 % RD | Straight line: ± 0.25 % RD ( * 10: 1 range), ± 0.1 % RD (when linearse correction function) Reproduction: ± 0.1 % RD | min.42.5 max.425 | min.7.57 max.75.7 | By pickup | 4ms or less | MAX 40MPa (standard) * There is also an optional high -pressure model. |