■ For measuring fuel, refrigerant, lubricating oil, and ultra -pure water The turbine flow meter DM series includes a wide range of fuel, refrigerant, and lubricating oil monitoring and foods, measurement of doses in pharmaceutical categories, surveillance and measurement of ultra -pure water in the R & D department, and fuel efficiency measurement of diesel fuel. It can be used for application. ■ Overview ・ Uses a helical rotor blade designed to reduce pressure loss ・ Adopt precision ball bearing that improves reproducibility and optimal measurement results at low flow ・ Built -in temperature sensor in a pickup sensor to correct temperature and viscosity in real time ■ Applications Aircraft -related, gas turbine, gasheat pump, etc. ■ Features ・ Calibration is performed by Trigasfi. ・ TRIGASFI is a DAKKS certified proofing organization for international MRA. ・ DAKKS calibration is proven by submission of DAKKS calibration certificate only. ・ TRIGASFI is one of the few calibration organizations that can be calibrated with actual viscosity and actual liquid under the ISO/IEC17025 certification standard.

  • Product

    High -precision / high -speed response turbine flow meter DM series

Share this product


1120+ people viewing

Last viewed: 49 minutes ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

10 Models of High -precision / high -speed response turbine flow meter DM series

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Diameter Expansion measurement range / L / min Fluid viscosity K factor / p / l Measurement accuracy Measurement range / L / min / RF & MAG Operating temperature Pressure loss (KPA) Response time Usage pressure
High -precision / high -speed response turbine flow meter DM series-Part Number-DM2-8

DM2-8

Available upon quote 1/2 " Rf min. 0.05
Mag min. 0.4
All Max. 5.5
Calibrated with the same viscosity according to the terms of use. (Standard: 1.3 mm²/s) 14,700 Straight linear ± 0.5 % RD / ± 0.1 % RD (when linear rise correction function)
Reproduction ± 0.05 % RD
min. 0.5
Max. 5.0
-270 ℃ ~ + 400 ° C (with bearings, pickups) 10% 0
25% 1
40% 3
55% 5
70% 8
85% 11
100% 15
4ms or less MAX 54MPa (an switch) / MAX 3.4MPa (hose switch) / MAX 5.0MPa (Tri-Clamp)
High -precision / high -speed response turbine flow meter DM series-Part Number-DM4-8

DM4-8

Available upon quote 1/2 " Rf min. 0.1
Mag min. 0.4
All Max. 13
Calibrated with the same viscosity according to the terms of use. (Standard: 1.3 mm²/s) 8,700 Straight linear ± 0.5 % RD / ± 0.1 % RD (when linear rise correction function)
Reproduction ± 0.05 % RD
min. 0.95
Max. 12
-270 ℃ ~ + 400 ° C (with bearings, pickups) 10% 1
25% 3
40% 6
55% 16
70% 19
85% 27
100% 35
4ms or less MAX 54MPa (an switch) / MAX 3.4MPa (hose switch) / MAX 5.0MPa (Tri-Clamp)
High -precision / high -speed response turbine flow meter DM series-Part Number-DM6-8

DM6-8

Available upon quote 1/2 " Rf min. 0.2
Mag min. 0.5
All Max. 24
Calibrated with the same viscosity according to the terms of use. (Standard: 1.3 mm²/s) 4,860 Straight linear ± 0.5 % RD / ± 0.1 % RD (when linear rise correction function)
Reproduction ± 0.05 % RD
min.9
Max. 20
-270 ℃ ~ + 400 ° C (with bearings, pickups) 10% 1
25% 2
40% 6
55% 11
70% 16
85% 23
100% 32
4ms or less MAX 54MPa (an switch) / MAX 3.4MPa (hose switch) / MAX 5.0MPa (Tri-Clamp)
High -precision / high -speed response turbine flow meter DM series-Part Number-DM8-8

DM8-8

Available upon quote 1/2 " Rf min. 0.03
Mag min. 0.6
All Max. 38
Calibrated with the same viscosity according to the terms of use. (Standard: 1.3 mm²/s) 3,700 Straight linear ± 0.5 % RD / ± 0.1 % RD (when linear rise correction function)
Reproduction ± 0.05 % RD
min.8
Max. 33
-270 ℃ ~ + 400 ° C (with bearings, pickups) 10% 1
25% 5
40% 11
55% 20
70% 30
85% 46
100% 61
4ms or less MAX 54MPa (an switch) / MAX 3.4MPa (hose switch) / MAX 5.0MPa (Tri-Clamp)
High -precision / high -speed response turbine flow meter DM series-Part Number-DM-08

DM-08

Available upon quote 1/2 " Rf min. 0.4
Mag min. 0.8
All Max. 48
Calibrated with the same viscosity according to the terms of use. (Standard: 1.3 mm²/s) 2,400 Straight linear ± 0.5 % RD / ± 0.1 % RD (when linear rise correction function)
Reproduction ± 0.05 % RD
min. 3.0
Max. 40
-270 ℃ ~ + 400 ° C (with bearings, pickups) 10% 1
25% 3
40% 8
55% 14
70% 21
85% 29
100% 36
4ms or less MAX 54MPa (an switch) / MAX 3.4MPa (hose switch) / MAX 5.0MPa (Tri-Clamp)
High -precision / high -speed response turbine flow meter DM series-Part Number-DM-10

DM-10

Available upon quote 5/8 " Rf min. 0.6
Mag min. 1.1
All Max. 70
Calibrated with the same viscosity according to the terms of use. (Standard: 1.3 mm²/s) 1,700 Straight linear ± 0.5 % RD / ± 0.1 % RD (when linear rise correction function)
Reproduction ± 0.05 % RD
min. 4.5
Max. 60
-270 ℃ ~ + 400 ° C (with bearings, pickups) 10% 6
25% 12
40% 23
55% 41
70% 61
85% 92
100% 122
4ms or less MAX 54MPa (an switch) / MAX 3.4MPa (hose switch) / MAX 5.0MPa (Tri-Clamp)
High -precision / high -speed response turbine flow meter DM series-Part Number-DM-12

DM-12

Available upon quote 3/4 " Rf min. 0.9
Mag min. 1.9
All Max. 120
Calibrated with the same viscosity according to the terms of use. (Standard: 1.3 mm²/s) 1,000 Straight linear ± 0.5 % RD / ± 0.1 % RD (when linear rise correction function)
Reproduction ± 0.05 % RD
min.6
Max. 90
-270 ℃ ~ + 400 ° C (with bearings, pickups) 10% 6
25% 13
40% 24
55% 42
70% 64
85% 93
100% 122
4ms or less MAX 54MPa (an switch) / MAX 3.4MPa (hose switch) / MAX 5.0MPa (Tri-Clamp)
High -precision / high -speed response turbine flow meter DM series-Part Number-DM-16

DM-16

Available upon quote 1 " Rf min. 2.2
Mag min. 3.8
All Max. 240
Calibrated with the same viscosity according to the terms of use. (Standard: 1.3 mm²/s) 450 Straight linear ± 0.5 % RD / ± 0.1 % RD (when linear rise correction function)
Reproduction ± 0.05 % RD
min. 19
Max. 220
-270 ℃ ~ + 400 ° C (with bearings, pickups) 10% 6
25% 9
40% 16
55% 27
70% 39
85% 57
100% 74
4ms or less MAX 54MPa (an switch) / MAX 3.4MPa (hose switch) / MAX 5.0MPa (Tri-Clamp)
High -precision / high -speed response turbine flow meter DM series-Part Number-DM-20

DM-20

Available upon quote 1 1/4 " Rf min. 3.8
Mag min. 6.0
All Max. 490
Calibrated with the same viscosity according to the terms of use. (Standard: 1.3 mm²/s) 240 Straight linear ± 0.5 % RD / ± 0.1 % RD (when linear rise correction function)
Reproduction ± 0.05 % RD
min. 34
Max. 400
-270 ℃ ~ + 400 ° C (with bearings, pickups) 10% 6
25% 13
40% 24
55% 43
70% 62
85% 96
100% 131
4ms or less MAX 54MPa (an switch) / MAX 3.4MPa (hose switch) / MAX 5.0MPa (Tri-Clamp)
High -precision / high -speed response turbine flow meter DM series-Part Number-DM-24

DM-24

Available upon quote 1 1/2 " Rf min. 6.0
Mag min. 10
All Max. 820
Calibrated with the same viscosity according to the terms of use. (Standard: 1.3 mm²/s) 110 Straight linear ± 0.5 % RD / ± 0.1 % RD (when linear rise correction function)
Reproduction ± 0.05 % RD
min. 57
Max. 700
-270 ℃ ~ + 400 ° C (with bearings, pickups) 10% 7
25% 16
40% 32
55% 60
70% 89
85% 132
100% 174
4ms or less MAX 54MPa (an switch) / MAX 3.4MPa (hose switch) / MAX 5.0MPa (Tri-Clamp)

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Krone Co., Ltd.


View more products of Krone Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree