Internal liquid -free pH/ORP sensor 8000 series-S8000CD
Internal liquid -free pH/ORP sensor 8000 series-IWAKI CO., LTD.

Internal liquid -free pH/ORP sensor 8000 series
IWAKI CO., LTD.


About This Product

■ The body material is PPS resin The material of the sensor itself adopts PPS resin and has excellent corrosion resistance and temperature resistance. ■ Internal solution without replenishment type Since the internal liquid -free type, there is no leakage of the internal solution, and there is no contamination of the measured solution. ■ Increased internal solution KCL internal liquid capacity has been increased 1.7 times compared to our conventional product. ■ Easy electrode replacement The electrodes are extremely easy to replace and maintain due to the TNC connector connection. ■ 3 types shared electrodes The electrode structure is a general / immersion / distribution type, and each type has a common electrode. ■ Reduced noise The noise problem is reduced by adding an amplifier signal conversion adapter.

  • Product

    Internal liquid -free pH/ORP sensor 8000 series




*Please note that we may not be able to accommodate sample requests.

2 Models of Internal liquid -free pH/ORP sensor 8000 series

Items marked with have different values ​​depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Body material Electrode shape Electrode structure Electrodes material material Measurement range Operating temperature limit Temperature compensation element Used pressure range type
Internal liquid -free pH/ORP sensor 8000 series-Part Number-S8000CD

S8000CD

Available upon quote Pps Flat type Composite electrode Glass 0 ~ 14ph
* The measurement range when sodium ions are included in the measurement solution is 0 to 12.3PH.
10 to 60 ° C Yes: Pt1,000Ω/None 0 ~ 0.3MPa General/immersion/distribution
Internal liquid -free pH/ORP sensor 8000 series-Part Number-S8000CD-Orp

S8000CD-Orp

Available upon quote Pps Flat type Composite electrode Shirokane / glass -1,999MV ~+1,999MV
* When using a signal conversion adapter, the measurement range is -1,000 mv ~+1,000 mV.
10 to 60 ° C none 0 ~ 0.3MPa General/immersion/distribution

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of IWAKI CO., LTD.


View more products of IWAKI CO., LTD.

About Company Handling This Product

IWAKI CO., LTD.

  • Japan
  • Since 1956
  • 994 employees

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree