About This Product
High humidity / harsh environment temperature Humidity dew point transmitter
feature
・ Heating function
・ Measurement near condensation (J, K type)
・ Chemical substance purge after chemical contamination
・ It can be measured up to high temperature at a temperature of 180 ° C and high pressure of 10 MPa.
・ Early recovery after condensation (C, D, E, I type)
・ Maximum pressure 10MPa (I type)
・ Sensor coding (optional)
Main use
・ Russian point management in front of the blower
・ Water management in the industrial furnace
・ Evaluation test of fuel cells
・ Humidity control of environmental test machines
・ Humidity control of dryer
・ Food and pharmaceutical industry
·weather
・ High -wet insurance tube
・ Ceramic, wood, concrete, polyester dryer
For high humidity and harsh environment
The EE33 series is the highest temperature dew transmitter of the highest peak of E+E series. Under the most severe conditions (such as high temperature), high -response speeds and relative humidity, dew points, absolute humidity, etc. are possible.
In general, under condensation and severe environments, it has a negative effect on the speed and reliability during temperature and humidity measurement. EE33 is powerful even under the pressure of up to 10 MPa or in an environment where high humidity continues. The detection department of the EE33 series uses the highest performance HMC01 monolithic polymer sensor manufactured using the thin film technology of E+E company. In the HMC01 monolithic sensor, the detection unit is regularly warmed by the sensor heating function, so even if condensation and chemical substances adhere to the detection portion, it is possible to make stable measurements for a long time.
In addition, the sensor coating (optional) based on the unique technology of E+E has enhanced HMC01 prevention of chemical resistance, corrosion resistance and leakage.
Various selections
EE33 can be selected from various models and mounting methods, so it can be used in many applications.
● Measurement of temporary dew condensation, relative humidity measurement in chemical contamination environment: The sensor detection unit is regularly warmed by the heating function, and the condensation and contamination attached to the detection portion is skipped.
● Dew point measurement in high humidity environment: There is a model that continues to heat the sensor detection unit when the humidity exceeds about 76%(K type).
● Relative humidity measurement in high humidity environment: Since the temperature probe and humidity probe are separated, measurements can be continued even during the heating function (J type).
Configuration software makes it easier to set functions and output/functions.