Flowload measurement of liquid flow meter PROLINE PROMAG P 300 Electromagnetic flow meter-Proline Promag P 300
Flowload measurement of liquid flow meter PROLINE PROMAG P 300 Electromagnetic flow meter-Endress+Hauser Group Services AG

Flowload measurement of liquid flow meter PROLINE PROMAG P 300 Electromagnetic flow meter
Endress+Hauser Group Services AG


About This Product

High -temperature fluid flow meter for process applications with integrated and easy -to -access converts ■ Applications Promag P is the optimal flow meter for chemical and process applications that handle corrosion liquids and high -temperature fluids. Promag P 300, which has an integrated converter, provides flexibility in operability and system integration. In other words, only one lid has to be opened for connection, etc., and a separation indicator is also available. In addition, we support various communications. Heartbeat Technology always guarantees the conformity and process safety to the relevant standards. ・ The measurement principle of two -way measurement is hardly affected by pressure, density, temperature, and viscosity. ・ A flow meter that is optimal for chemical and process applications that handle corrosive liquids and high -temperature fluids. ■ Features of equipment ・ Call caliber: up to 600 mm (24 ") ・ Corresponds to all general explosion -proof certification ・ Use PTFE or PFA for the lining material ・ Compact dual compartment housing, with up to three I/O ・ Backlight display with touch control and WLAN connection ・ A separate display can be used ■ Advantages ・ Various applications - Various adventions ・ Energy -saving type flow rate measurement -No pressure loss because there is no flow route restriction ・ Maintenance -free -No movable part ・ Full access to processes and diagnostic information -I/O and field buses that can be combined by various ・ Relieving complexity and diversity -I/O functions that can be set arbitrarily ・ Built -in verification function - HeartBeat Technology ■ Product ・ High -temperature process application for high -temperature process applications with conversions that are easy to access. ・ Ideal for chemical industry and process applications that handle corrosive liquids and high -temperature fluids ■ Features of sensor ・ Compatible with various applications depending on the diverse envelope material. ・ Energy -saving type flow measurement -No pressure loss due to reduced cross section. ・ Maintenance -free -No movable portion. ・ Call diameter: up to 600 A (24 ""). ・ Corresponds to all general explosion -proof certification. ■ Features of converter ・ Full access to processes and diagnostic information -Various I/O and field bus can be combined arbitrarily. ・ Relieving complexity and diversity -an I/O function that can be set arbitrarily. ・ Equipped with verification function Heartbeat Technology. ・ PTFE or PFA lining. ・ Compact dual compartment housing, with up to three I/O. ・ A display part with backlight with a touch control and WLAN connection. ・ Separation display can be used.

  • Product

    Flowload measurement of liquid flow meter PROLINE PROMAG P 300 Electromagnetic flow meter

Share this product


320+ people viewing


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

1 Models of Flowload measurement of liquid flow meter PROLINE PROMAG P 300 Electromagnetic flow meter

Product Image Part Number Price (excluding tax) Call caliber range Certification and authentication regarding measurement Digital communication Display / operation Explosion -proof certification Ferry class certification and authentication Functional safety Liquid part material Material certificate Material of converter housing Materials of sensor housing Maximum measurement error Maximum process pressure Measured value Measurement principle Measurement range Peripheral temperature range Pressure certification and authentication Process temperature of measurements Product safety Protection grade Sanitari certification and authentication input output power supply
Flowload measurement of liquid flow meter PROLINE PROMAG P 300 Electromagnetic flow meter-Part Number-Proline Promag P 300

Proline Promag P 300

Available upon quote 15 ~ 600 mm (½ ~ 24 ") Calibration at certification facilities (compliant with ISO/IEC 17025)
HeartBeat Technology corresponds to measurement traceability requests conformed to ISO 9001: 2015 - Section 7.1.5.2 a (Tüv Süd certificate)
HART, Profibus DP, Profibus PA, Foundation Field Bus, Modbus RS485, Profinet, Ethernet/IP, OPC-UA 4 lines display, display part with backlight, touch control (operated from outside)
Can be set from site display and operation tools
Separate display can be used
ATEX, IECEX, CCSAUS, InMetro, NEPSI, EAC, UK EX LR certification, DNV GL certification, ABS certification, BV certification Compatible with functional safety that complies with IEC 61508, functional safety applications compliant with IEC 61511 Lining: PFA; ptfe
Electrode: 1.4435 (equivalent to SUS F316L); Aloy C22, 2.4602 (UNS N06022); Tantal; Shirokane; Titanium
3.1 Material certificate ALSI10mg, coating; 1.4409 (CF3M) equivalent to SUS316L; Stainless steel suitable for sanitari converter 15 ~ 300 mm (½ ~ 12 "): ALSI10mg, coating
350 ~ 600 mm (14 ~ 24 "): Carbon steel with protective paint
Volume flow rate (standard): ± 0.5 % O.R. 1 mm/s (0.04 in/s)
Volume (option) ± 0.2 % O.R. ± 2 mm/s (0.08 in/s)
PN 40, Class 300, 20k Volume flow rate, conductive rate, mass flow rate Electromagnetic format 4 DM³/min ~ 9600 m³/h (1 gal/min ~ 44000 gal/min) Flange material carbon steel: --10 ~+60 ° C (+14 ~+140 ° f)
Flange material stainless steel --40 ~+60 ° C (–40 ~+140 ° f)
PED, CRN Lining material PFA: --20 ~+150 ° C (--4 ~+302 ° F)
Lining material PFA High temperature: --20 ~+180 ° C (--4 ~+356 ° F)
Lining material PTFE: --40 ~+130 ° C (–40 ~+266 ° f)
CE, C-Tick, EAC Marking Standard: IP66/67, Type 4X container ACS, NSF 61, WRAS Status input
4-20 MA input
3 Output:
4-20 MA Hot (Active/Passive)
4-20 MA Wirelesshart
4-20 MA (Active/Passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output
DC 24 V
AC 100-230 V
AC 100-230 V / DC 24 V (non -dangerous place)

Customers who viewed this product also viewed

Other products of Endress+Hauser Group Services AG


View more products of Endress+Hauser Group Services AG

About Company Handling This Product

Endress+Hauser Group Services AG

  • United States of America

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree