Product
Non-contact temperature sensor for metal and composite materials-Thermometer CT-M3Handling Company
Micro-Epsilon JAPAN K.K.Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Alarm output | Ambient temperature | Calibration certificate | Optical resolution | Output impedance current output | Output impedance voltage output | Output/Digital (optional) | Output/analog (optional) | Output/analog channel 1 | Permeability | Protection grade | Radiation rate/amplification | Relative humidity | Repetition | Response time | Sensor cable length | Shock sensor | Signal processing | Spectral area | Storage temperature | System accuracy | Temperature range | Temperature resolution (digital) | Vibration sensor | input | mass | power supply |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CTM-3SF22-C3 |
Available upon quote | Open collector (24V/50mA) | Sensor: -40 ° C to 85 ° C; Controller: 0 ° C to 85 ℃ | option | 22: 1 | Up to 500Ω load (for 8-36V DC) | The minimum load resistance 100kΩ, thermoelement 20Ω | USB, RS232, RS485, CAN, Profibus DP, Ethernet | Relay 2 x 60V DC/42V Aceff, 0.4A, no voltage | 0/4-20mA, 0 to 5/10V, Thermoelette J, K | 0.100-1.100 | IP65 (NEMA-4) | 0.100-1.100 | 10-95%, no condensation | ± (0.1% T measured +1 ℃) | 1ms (90%) | 3 m | IEC 68-27: 50g, 11ms, each axis | Expansion hold function with peak hold, valley hold, average; threshold and hysteresis | 2.3 µm | Sensor: -40 ° C to 125 ° C; Controller: -40 ° C to 85 ℃ | ± (0.3% T measured +2 ℃) | 50-400 ℃ | 0.1 ℃ | IEC 68-2-6: 3g, 11-200Hz, each axis | Function input peripheral temperature correction, trigger (reset, hold function) | Sensor: 40g; Controller: 420g | 8-36V DC, up to 100mA | |
CTM-3SF33-C3 |
Available upon quote | Open collector (24V/50mA) | Sensor: -40 ° C to 85 ° C; Controller: 0 ° C to 85 ℃ | option | 33: 1 | Up to 500Ω load (for 8-36V DC) | The minimum load resistance 100kΩ, thermoelement 20Ω | USB, RS232, RS485, CAN, Profibus DP, Ethernet | Relay 2 x 60V DC/42V Aceff, 0.4A, no voltage | 0/4-20mA, 0 to 5/10V, Thermoelette J, K | 0.100-1.100 | IP65 (NEMA-4) | 0.100-1.100 | 10-95%, no condensation | ± (0.1% T measured +1 ℃) | 1ms (90%) | 3 m | IEC 68-27: 50g, 11ms, each axis | Expansion hold function with peak hold, valley hold, average; threshold and hysteresis | 2.3 µm | Sensor: -40 ° C to 125 ° C; Controller: -40 ° C to 85 ℃ | ± (0.3% T measured +2 ℃) | 100-600 ° C | 0.1 ℃ | IEC 68-2-6: 3g, 11-200Hz, each axis | Function input peripheral temperature correction, trigger (reset, hold function) | Sensor: 40g; Controller: 420g | 8-36V DC, up to 100mA | |
CTM-3SF75H1-C3 |
Available upon quote | Open collector (24V/50mA) | Sensor: -40 ° C to 85 ° C; Controller: 0 ° C to 85 ℃ | option | 75: 1 | Up to 500Ω load (for 8-36V DC) | The minimum load resistance 100kΩ, thermoelement 20Ω | USB, RS232, RS485, CAN, Profibus DP, Ethernet | Relay 2 x 60V DC/42V Aceff, 0.4A, no voltage | 0/4-20mA, 0 to 5/10V, Thermoelette J, K | 0.100-1.100 | IP65 (NEMA-4) | 0.100-1.100 | 10-95%, no condensation | ± (0.1% T measured +1 ℃) | 1ms (90%) | 3 m | IEC 68-27: 50g, 11ms, each axis | Expansion hold function with peak hold, valley hold, average; threshold and hysteresis | 2.3 µm | Sensor: -40 ° C to 125 ° C; Controller: -40 ° C to 85 ℃ | ± (0.3% T measured +2 ℃) | 150-1,000 ° C | 0.1 ℃ | IEC 68-2-6: 3g, 11-200Hz, each axis | Function input peripheral temperature correction, trigger (reset, hold function) | Sensor: 40g; Controller: 420g | 8-36V DC, up to 100mA |