V100 vibration measuring instrumentHandling Company
UnipulusCategories
Product Image | Part Number | Price (excluding tax) | Analog club analog filter | Analog club monitor output | Analog portion applied voltage | Analog section A / D converter | Analog section signal input range | Display display | Display portion small number | Display unit | External signal input (11 points) | External signal output (9 points) | General performance external dimensions | General performance power consumption | General performance power supply voltage | General performance rush current (TYP) | General performance usage conditions | General performance weight | Indicated portion indicated value display range | Interface | Number of display portions displayed | Operation unit input instrument | Record record data | Recording department recording media | Temperature measurement | Vibration diagnostic part vibration analysis (FFT) | Vibration diagnostic portion vibration detection | accessories |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
V100 |
Available upon quote | Select from the primary loop filter cut -off frequency 30, 100, 1k Hz | Output level: Approximately 1 V (approx. 1 V / g) per 50 MV (about 1 V / g) load resistance: 2 kΩ or more | DC 5 V ± 10 % output current: within 30 mA | Speed: 2,000 times / second resolution ability: 24 Bit (binary) Effective resolution ability: about 1/10,000 for 150 MV | ± 150 MV (UNA02 can be measured up to MAX3 G) | 3.5 inch STN Color LCD display area: 71 (W) × 53 (H) mm dot configuration: 320 × 240 dot | 0 / 0.0 / 0.00 / 0.000 | None, m / s2, mm / s2, mm / s, mm / s, mm, μm, % | Hold control (T / H, Section), graph control (Graph Trig), FFT control (FFT TRIG), work selection (WORK0 -Work3), comparative values (Cal0, cal1), Operation prohibited (Lock) Voltage input circuit (plus komon / minus comon shared) On -on. Pressure: DC 12 V or more, OFF voltage DC 3 V or less, Steering current: about 5 mA (during DC 24 V), insulating method: Photoba plastic instruction | Comparison result (HH, Hi, OK, Lo, LL), hold completion (Hold end), normal operation (RUN), graph drawing (EVENT), SD card normal (SD Card), open collector output circuit (sync type plus comon input equipment connection possible), rated voltage: DC 30 V, rated voltage. Current: 30 mA or less, insulating method: Photobapura instructions | 99.5 (W) x 96 (H) x 117.3 (d) mm (not included) | 7 W type | DC 24 V (± 15 %) | 2 a, 10 msec (at room temperature, cold start) | Used temperature range 0 ° C to +40 ° C / storage temperature range -20 ° C to + 60 ° C humidity 85% RH or less (condensation not possible) | Approximately 1.0 kg | 4 digits ± 9,999 | RS-232C communication interface | 3 times / second fixed | Analog type touch panel | Measurement waveform data (up to 99.9 seconds 100 files) Measurement result data (10 files 1 file for each work ≒ 5 MB 65,530 times) FFT screen data (100 files) | SD card | Record the temperature at the time of vibration measurement (history, SD card) Temperature measurement range: -10 ° C to + 90 ° C, accuracy: ± 1.5 ° C, decomposition ability: 0.01 ° C. | Sampling magnification: 1x / 2 times / 4 times / 8 times window function: square / honey / humming / blackman analysis mode: Average vibration value / envelope (moving average per frequency) display range: 99.9 DBMAX display mode: continuous / single -shot | Breaking filter: High pass filter 1-500 Hz Low Pass filter 1-500 Hz (secondary buttower characteristic digital filter) Configuration: 16 patterns (switched by external input and communication) | Instruction manual, connector for external input / output, SD card, acceleration sensor, temperature sensor |