Product
Turkmeter slip -slip rotation Torque meter UTMⅡHandling Company
UnipulusItems marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Allowed overload | Attached cable | CE marking conformity | Case size | Current consumption current | Hysterical | Input Power | Measurable upper limit | Moment of inertia | Non -linear | Operating temperature range | Optional measurement range | Output range | Pulse output | Rated twist angle | Repetition | Shaft diameter | Solded cable | Temperature effects of output | Temperature effects of zero points | Twisting constant | full length | option | responsiveness | weight |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
UTMⅡ-0.05nm |
Available upon quote | 500% FS | 6 Core robot cable 2 meter-end Yanagi Line → Cable length can be replaced with 5 m (option: UTMⅡ-L5) | EMC Directive: EN61326-1, EN61326-2-3 | 54 x 50 x 40 mm | 100ma or less | 0.03% FS or less | DC 24 V ± 15% | 25,000rpm | 8.77 x 10-6kgm2 | 0.03% FS or less | -10 ~+50 ℃ | ± 0.05 nm | ± 5V load resistance: 2 kΩ or more | 1 turn 4 pulse output Open collector Output rated DC30V 10ma | 88.1 x 10-3 RAD (0.505 °) | 0.03% FS or less | φ5mm | CATM51: 6 Core robot cable 5m Advanced Yanagi Line CATM12: 6 Core robot cable 10m Advanced Yanagi Line | 0.01% FS / ℃ or less | 0.01% FS / ℃ or less | 5.67nm / Rad | 74mm | Rotary encoder | 1KHz | Approximately 160g | |
UTMⅡ-0.1nm |
Available upon quote | 500% FS | 6 Core robot cable 2 meter-end Yanagi Line → Cable length can be replaced with 5 m (option: UTMⅡ-L5) | EMC Directive: EN61326-1, EN61326-2-3 | 54 x 50 x 40 mm | 100ma or less | 0.03% FS or less | DC 24 V ± 15% | 25,000rpm | 8.87 x 10-6kgm2 | 0.03% FS or less | -10 ~+50 ℃ | ± 0.1 nm | ± 5V load resistance: 2 kΩ or more | 1 turn 4 pulse output Open collector Output rated DC30V 10ma | 8.64 x 10-3 RAD (0.495 °) | 0.03% FS or less | φ5mm | CATM51: 6 Core robot cable 5m Advanced Yanagi Line CATM12: 6 Core robot cable 10m Advanced Yanagi Line | 0.01% FS / ℃ or less | 0.01% FS / ℃ or less | 11.57nm / Rad | 74mm | Rotary encoder | 1KHz | Approximately 160g | |
UTMⅡ-0.2nm |
Available upon quote | 500% FS | 6 Core robot cable 2 meter-end Yanagi Line → Cable length can be replaced with 5 m (option: UTMⅡ-L5) | EMC Directive: EN61326-1, EN61326-2-3 | 54 x 50 x 40 mm | 100ma or less | 0.03% FS or less | DC 24 V ± 15% | 25,000rpm | 8.99 x 10-6kgm2 | 0.03% FS or less | -10 ~+50 ℃ | ± 0.2 nm | ± 5V load resistance: 2 kΩ or more | 1 turn 4 pulse output Open collector Output rated DC30V 10ma | 7.66 x 10-3 RAD (0.439 °) | 0.03% FS or less | φ5mm | CATM51: 6 Core robot cable 5m Advanced Yanagi Line CATM12: 6 Core robot cable 10m Advanced Yanagi Line | 0.01% FS / ℃ or less | 0.01% FS / ℃ or less | 26.10nm / Rad | 74mm | Rotary encoder | 1KHz | Approximately 160g | |
UTMⅡ-0.5nm |
Available upon quote | 500% FS | 6 Core robot cable 2 meter-end Yanagi Line → Cable length can be replaced with 5 m (option: UTMⅡ-L5) | EMC Directive: EN61326-1, EN61326-2-3 | 54 x 50 x 40 mm | 100ma or less | 0.03% FS or less | DC 24 V ± 15% | 25,000rpm | 1.49 x 10-6kgm2 | 0.03% FS or less | -10 ~+50 ℃ | ± 0.5 nm | ± 5V load resistance: 2 kΩ or more | 1 turn 4 pulse output Open collector Output rated DC30V 10ma | 5.37 x 10-3 RAD (0.308 °) | 0.03% FS or less | φ8mm | CATM51: 6 Core robot cable 5m Advanced Yanagi Line CATM12: 6 Core robot cable 10m Advanced Yanagi Line | 0.01% FS / ℃ or less | 0.01% FS / ℃ or less | 93.1nm / Rad | 84mm | Rotary encoder | 1KHz | Approximately 180g | |
UTMⅡ-1nm |
Available upon quote | 500% FS | 6 Core robot cable 2 meter-end Yanagi Line → Cable length can be replaced with 5 m (option: UTMⅡ-L5) | EMC Directive: EN61326-1, EN61326-2-3 | 54 x 50 x 40 mm | 100ma or less | 0.03% FS or less | DC 24 V ± 15% | 25,000rpm | 1.52 x 10-6kgm2 | 0.03% FS or less | -10 ~+50 ℃ | ± 1 nm | ± 5V load resistance: 2 kΩ or more | 1 turn 4 pulse output Open collector Output rated DC30V 10ma | 5.32 x 10-3 RAD (0.305 °) | 0.03% FS or less | φ8mm | CATM51: 6 Core robot cable 5m Advanced Yanagi Line CATM12: 6 Core robot cable 10m Advanced Yanagi Line | 0.01% FS / ℃ or less | 0.01% FS / ℃ or less | 188nm / Rad | 84mm | Rotary encoder | 1KHz | Approximately 180g | |
UTMⅡ-2nm |
Available upon quote | 500% FS | 6 Core robot cable 2 meter-end Yanagi Line → Cable length can be replaced with 5 m (option: UTMⅡ-L5) | EMC Directive: EN61326-1, EN61326-2-3 | 54 x 50 x 40 mm | 100ma or less | 0.03% FS or less | DC 24 V ± 15% | 25,000rpm | 1.42 x 10-6kgm2 | 0.03% FS or less | -10 ~+50 ℃ | ± 2 nm | ± 5V load resistance: 2 kΩ or more | 1 turn 4 pulse output Open collector Output rated DC30V 10ma | 4.83 x 10-3 RAD (0.277 °) | 0.03% FS or less | φ8mm | CATM51: 6 Core robot cable 5m Advanced Yanagi Line CATM12: 6 Core robot cable 10m Advanced Yanagi Line | 0.01% FS / ℃ or less | 0.01% FS / ℃ or less | 414nm / Rad | 84mm | Rotary encoder | 1KHz | Approximately 180g | |
UTMⅡ-5nm |
Available upon quote | 500% FS | 6 Core robot cable 2 meter-end Yanagi Line → Cable length can be replaced with 5 m (option: UTMⅡ-L5) | EMC Directive: EN61326-1, EN61326-2-3 | 57 x 55 x 40 mm | 100ma or less | 0.03% FS or less | DC 24 V ± 15% | 25,000rpm | 3.56 x 10-6kgm2 | 0.03% FS or less | -10 ~+50 ℃ | ± 5 nm | ± 5V load resistance: 2 kΩ or more | 1 turn 4 pulse output Open collector Output rated DC30V 10ma | 7.24 x 10-3 RAD (0.415 °) | 0.03% FS or less | φ12mm | CATM51: 6 Core robot cable 5m Advanced Yanagi Line CATM12: 6 Core robot cable 10m Advanced Yanagi Line | 0.01% FS / ℃ or less | 0.01% FS / ℃ or less | 691nm / Rad | 97mm | Key groove Rotary Encod Key groove & encoder | 1KHz | Approximately 270g | |
UTMⅡ-10nm |
Available upon quote | 500% FS | 6 Core robot cable 2 meter-end Yanagi Line → Cable length can be replaced with 5 m (option: UTMⅡ-L5) | EMC Directive: EN61326-1, EN61326-2-3 | 54 x 50 x 40 mm | 100ma or less | 0.03% FS or less | DC 24 V ± 15% | 25,000rpm | 3.66 x 10-6kgm2 | 0.03% FS or less | -10 ~+50 ℃ | ± 10 nm | ± 5V load resistance: 2 kΩ or more | 1 turn 4 pulse output Open collector Output rated DC30V 10ma | 5.40 × 10-3 RAD (0.310 °) | 0.03% FS or less | φ12mm | CATM51: 6 Core robot cable 5m Advanced Yanagi Line CATM12: 6 Core robot cable 10m Advanced Yanagi Line | 0.01% FS / ℃ or less | 0.01% FS / ℃ or less | 1,851nm / Rad | 97mm | Key groove Rotary Encod Key Groo & Encoda Division & Encoda | 1KHz | Approximately 270g | |
UTMⅡ-20nm |
Available upon quote | 500% FS | 6 Core robot cable 2 meter-end Yanagi Line → Cable length can be replaced with 5 m (option: UTMⅡ-L5) | EMC Directive: EN61326-1, EN61326-2-3 | 70 x 68 x 51 mm | 150ma or less | 0.03% FS or less | DC 24 V ± 15% | 20,000rpm | 2.60 x 10-6kgm2 | 0.03% FS or less | -10 ~+50 ℃ | ± 20nm | ± 5V load resistance: 2 kΩ or more | 1 turn 4 pulse output Open collector Output rated DC30V 10ma | 3.71 x 10-3 RAD (0.213 °) | 0.03% FS or less | φ20mm | CATM51: 6 Core robot cable 5m Advanced Yanagi Line CATM12: 6 Core robot cable 10m Advanced Yanagi Line | 0.01% FS / ℃ or less | 0.01% FS / ℃ or less | 5,386nm / RAD | 150mm | Key groove Rotary Encod Key Groo & Encoda Division & Encoda | 1KHz | Approximately 700g | |
UTMⅡ-50nm |
Available upon quote | 500% FS | 6 Core robot cable 2 meter-end Yanagi Line → Cable length can be replaced with 5 m (option: UTMⅡ-L5) | EMC Directive: EN61326-1, EN61326-2-3 | 70 x 68 x 51 mm | 150ma or less | 0.03% FS or less | DC 24 V ± 15% | 20,000rpm | 2.67 x 10-6kgm2 | 0.03% FS or less | -10 ~+50 ℃ | ± 50 nm | ± 5V load resistance: 2 kΩ or more | 1 turn 4 pulse output Open collector Output rated DC30V 10ma | 5.93 x 10-3 RAD (0.340 °) | 0.03% FS or less | φ20mm | CATM51: 6 Core robot cable 5m Advanced Yanagi Line CATM12: 6 Core robot cable 10m Advanced Yanagi Line | 0.01% FS / ℃ or less | 0.01% FS / ℃ or less | 8,438nm / Rad | 170mm | Key groove Rotary Encod Key Groo & Encoda Division & Encoda | 1KHz | Approximately 700g |
Click on the part number for more information about each product