Price (excluding tax)
■ Features ・ Wide area physics/chemical adsorption analysis device ・ 0.1 TORR sensor ・ For highly difficult catalytic measurement
You can search for other models from each index. The displayed value is the value of the currently selected part number.
1/0.1 TORR sensor accuracy (MP/XR)
Administration mode
Adsorbent
Analysis dwarry bottle
Bulk volume mode
Chemical absorption furnace (-c model)
Chemical adsorption analysis station (-c model)
Disconnection
Minimum pores
Minimum surface area
P/P0 range (XR using nitrogen/argon)
Physical adsorption analysis station
Physical specifications and utility
Refrigerant level control
Saturated steam pressure measurement
Standard ASTM
Standard DIN
Standard iOS
Vacuum system (MP/XR)
structure
Part Number
Autosorb IQ C-XRProduct
Gas adsorption measurement device high vacuum physics/chemical adsorbent analysis device Autosorb IQHandling Company
Anton Paar GmbHItems marked with have different values depending on the model number.
Product Image | Price (excluding tax) | 1/0.1 TORR sensor accuracy (MP/XR) | Administration mode | Adsorbent | Analysis dwarry bottle | Bulk volume mode | Chemical absorption furnace (-c model) | Chemical adsorption analysis station (-c model) | Disconnection | Minimum pores | Minimum surface area | P/P0 range (XR using nitrogen/argon) | Physical adsorption analysis station | Physical specifications and utility | Refrigerant level control | Saturated steam pressure measurement | Standard ASTM | Standard DIN | Standard iOS | Vacuum system (MP/XR) | structure |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Available upon quote | Less than 0.15 %of the measured value (manufacturer specification) | Goal P/P0: Maxidose (automatically adapt to the adsorption characteristics of each sample), VectorDose (fixed amount in multiple range) DOSEWIZARD (used as a template before analysis) | N2, AR, KR, CO2, O2, H2, etc. | 3 L, 90 hours or more (liquid nitrogen) | Automatic measurement, re -measurement at the time of analysis, reusing measured values, helium -free method | Maximum temperature: 1,100 ℃ Temperature speed: 1 ℃/min ~ 50 ° C/min In -furnace cooling by built -in fans | 1 | 4 dedicated, built -in detachable port, quartz mantle/glass device can operate an analysis up to 450 ° C at the same time, a vacuum level monitored in Pirani | 0.35 NM (dependence on analysis gas and temperature) | 0.01 M2/G (dependent on analysis gas and temperature) | 10-8 ~ 0.999 | 1, 2, or 3 | Width: 699mm Height: 1,035mm Depth: 705mm Weight: 148kg Power supply: AC100V ~ AC240V, 50/60 Hz, single -phase, etc. | Active sensor/elevator | Exclusive cell with dedicated sensor | B922, C1,069, C1,274, D1,993, D3,663, D3,908, D4,222, D4,365, D4,641, D4,780, D4,824, D6,556 | 66,134, 66,135-1, 66,135-2, 66,135-3, 66,135-4 | 9,277, 15,901-2, 15,901-3, 18,757 | Turbo-type molecular drag pump and dry layer fram pump, reaching vacant: 5 x 10-10 MBAR* | Available from metal vs. metal seals in important measurement zones, EPDM, Viton, PFE elastomer |