The best particle diameter distribution measurement device to perform the characteristics evaluation of nanoparticles and fine particles with one click litesizer-155761
The best particle diameter distribution measurement device to perform the characteristics evaluation of nanoparticles and fine particles with one click litesizer-Anton Paar GmbH

The best particle diameter distribution measurement device to perform the characteristics evaluation of nanoparticles and fine particles with one click litesizer
Anton Paar GmbH


About This Product

The Litesizer series is ideal for performing one click on the characteristic evaluation of nanoparticles and fine particles. The particles in the dispersion, peptides and polymer in solutions can be measured in a wide range of concentrations, reducing the time required for sample preparation. Litesizer 500 can measure particle diameter at three measurement angles. In addition, it is equipped with a patented CMPALS technology, and the zeta potential measurement at low voltage is achieved with high reproducibility and accuracy. ■ Main functions ・ Litesizer selects the optimal measurement angle for each sample and guarantees high data quality. ・ Measures the minimum concentration of 0.1 mg/ml ・ Always measure the transmittance for sample confirmation ・ All -in -one device -refractive index measurement ・ Clearly grasp the outline of measurement with Kalliope software

  • Product

    The best particle diameter distribution measurement device to perform the characteristics evaluation of nanoparticles and fine particles with one click litesizer




*Please note that we may not be able to accommodate sample requests.

2 Models of The best particle diameter distribution measurement device to perform the characteristics evaluation of nanoparticles and fine particles with one click litesizer

Items marked with have different values ​​depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Maximum concentration of zeta potential sample Maximum conductive rate of Zeta Priad Sample Maximum particle diameter concentration Minimal concentration of molecular weight sample Minimal concentration of zeta potential sample Molecular weight accuracy Molecular weight measurement angle Molecular weight measurement principle Molecular weight measurement range (mass) Molecular weight measurement range (particle diameter) Particle diameter measurement angle Particle diameter measurement principle Particle diameter measurement range Particle diameter minimum concentration Particle diameter minimum sample amount Particle size accuracy Permeability certainty Repeat molecular weight Repeated particle diameter accuracy The minimum amount of transmem on the permeability Transparent permeability measurement range Zeta Captricity Measurement Principles Zeta Code of Zeta Zeta Power Stage Repeat accuracy Zeta Power of Swimming Movement Zeta Power of particle diameter range Zeta potential measurement range Zeta potential minimum sample amount
The best particle diameter distribution measurement device to perform the characteristics evaluation of nanoparticles and fine particles with one click litesizer-Part Number-155761

155761

Available upon quote 70 %W/V (dependent on samples) 200 50 %W/V (dependent on samples) 0.1 mg/ml (liza team) 0.1 mg/ml (liza team) +/- 10 % 90 Static light scattering method (SLS) 980 DA ~ 20 MDA Diameter 40 nm or less 15 °, 90 °, 175 ° Dynamic light scattering method (DLS) 0.3 NM ~ 10 µm (diameter) 0.1 mg/ml (liza team) 12 +/- less than 2 %(NIST standard substances) +/- less than 1 % +/- 5 % +/- less than 2 %(NIST standard substances) 15 0 to 100 % Electric swimming light scattering method (ELS) / CMPALS +/- less than 10 % +/- 3 %AD2 10-11 ~ 2 × 10-7 m²/v · S 3.8 nm ~ 100 µm (diameter) > = +/- 1,000 MV 50 µL (dependent on sample viscosity)
The best particle diameter distribution measurement device to perform the characteristics evaluation of nanoparticles and fine particles with one click litesizer-Part Number-173050

173050

Available upon quote - - 50 %W/V (dependent on samples) - - - - - - - 175 Dynamic light scattering method (DLS) 0.3 NM ~ 10 µm (diameter) 0.1 mg/ml (liza team) 12 +/- less than 2 %(NIST standard substances) +/- less than 1 % - +/- less than 2 %(NIST standard substances) 15 0 to 100 % - - - - - - -

Click on the part number for more information about each product

Other products of Anton Paar GmbH


View more products of Anton Paar GmbH

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree