Measurement surface area/pole analysis device NOVA series that combines both speed and accuracy-NOVA 600 Bet
Measurement surface area/pole analysis device NOVA series that combines both speed and accuracy-Anton Paar GmbH

Measurement surface area/pole analysis device NOVA series that combines both speed and accuracy
Anton Paar GmbH


About This Product

The NOVA series is designed to provide simple operation and sample processing speed -speedy speed accuracy of sample in all analysis processes. It has four detachment stations and up to four analytical stations, and the 5 -point BET analysis of the sample 4 sample is performed in 20 minutes to achieve 2 %reproducibility. See how nova provides unparalleled advantages from beginning to end according to the workflow of the analysis tab below, and establishes the new standards for the characteristics of the surface area and the characteristics of pores. ■ Features ・ Simple, easy operation from beginning to end ・ Measurements that combine both speed and accuracy ・ Both today's measurement and tomorrow's measurement preparation ・ KAOMI for Nova seamless software ・ Versatile beyond the industry ・ Complete guarantee for 3 years

  • Product

    Measurement surface area/pole analysis device NOVA series that combines both speed and accuracy




*Please note that we may not be able to accommodate sample requests.

4 Models of Measurement surface area/pole analysis device NOVA series that combines both speed and accuracy

Items marked with have different values ​​depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Absolute surface area lower limit Analysis dwarry bottle Analysis gas Analysis profile with measurement conditions Analysis station Connection with PC Dimensions (depth x width x height) Dosewizard Electricity Independent P0 station KAOMI for Nova Software Liquid part material Lower limit of the ratio surface area Measurement principle Minimum pole volume Operating environment Pole diameter range PowerProtect Pressure decomposition ability Pressure measurement accuracy Relative pressure range (P/P0) Sample pretreatment Surface area reproducibility Truzone VECTORDOSE Vacuum connection Vacuum requirements display gas weight
Measurement surface area/pole analysis device NOVA series that combines both speed and accuracy-Part Number-NOVA 600 Bet

NOVA 600 Bet

Available upon quote 0.5 Capacity: 1 L
Time: Up to 7 hours
N2 only 20 or more (ASTM, USP, DIN, ISO) 2 Ethernet 44 cm x 63 cm x 84 cm can be Supply: AC 100-240 V, 50 /60 Hz consumption: 345 VA (maximum) can be Equipment control: Up to 4 units
6 Language: English, French, German, Japanese, Chinese, Spanish
Stainless steel, viton elastomer 0.01 Vacuum volume measurement Not applicable Temperature: 15 ~ 35 OC
Humidity: 20 to 80% (relative), no condensation
Not applicable can be Absolutely: 1.2 x 10-4
TORR Relative: 1.5 x 10-7 P/P0
0.1 % (including the accuracy of the entire pressure measurement system, linear, hysteresis for full scale) 10-4 ~ 0.5 Integrated Type Detamination Station: 4
Temperature control: Two temperature rising zones, surrounding temperature ~ 425 OC
Available methods: Flow & vacuum removal, programmable multi -step heating profile
2% (implemented using authentication standard substance BAM P115) can be can be Rotary pump exhaust port, KF 16 Achievement vacuum 2.3 x 10-3 TORR 10 inch touch screen Port: 5 (3 for analysis, 1 for helium, removal gas/re -filling 1)
Purification: 99.999 % (HE, N2)
Input pressure: 8-10 psig
63
Measurement surface area/pole analysis device NOVA series that combines both speed and accuracy-Part Number-NOVA 800 Bet

NOVA 800 Bet

Available upon quote 0.5 Capacity: 1 L
Time: Up to 7 hours
N2 only 20 or more (ASTM, USP, DIN, ISO) Four Ethernet 44 cm x 63 cm x 84 cm can be Supply: AC 100-240 V, 50 /60 Hz consumption: 345 VA (maximum) can be Equipment control: Up to 4 units
6 Language: English, French, German, Japanese, Chinese, Spanish
Stainless steel, viton elastomer 0.01 Vacuum volume measurement Not applicable Temperature: 15 ~ 35 OC
Humidity: 20 to 80% (relative), no condensation
Not applicable can be Absolutely: 1.2 x 10-4
TORR Relative: 1.5 x 10-7 P/P0
0.1 % (including the accuracy of the entire pressure measurement system, linear, hysteresis for full scale) 10-4 ~ 0.5 Integrated Type Detamination Station: 4
Temperature control: Two temperature rising zones, surrounding temperature ~ 425 OC
Available methods: Flow & vacuum removal, programmable multi -step heating profile
2% (implemented using authentication standard substance BAM P115) can be can be Rotary pump exhaust port, KF 16 Achievement vacuum 2.3 x 10-3 TORR 10 inch touch screen Port: 5 (3 for analysis, 1 for helium, removal gas/re -filling 1)
Purification: 99.999 % (HE, N2)
Input pressure: 8-10 psig
63
Measurement surface area/pole analysis device NOVA series that combines both speed and accuracy-Part Number-NOVA 600

NOVA 600

Available upon quote 0.5 Capacity: 2 L
Time: Up to 40 hours
N2, AR, CO2, other non -corrosion gas 20 or more (ASTM, USP, DIN, ISO) 2 Ethernet 44 cm x 63 cm x 84 cm can be Supply: AC 100-240 V, 50 /60 Hz consumption: 345 VA (maximum) can be Equipment control: Up to 4 units
6 Language: English, French, German, Japanese, Chinese, Spanish
Stainless steel, viton elastomer 0.01 Vacuum volume measurement 1.2x10-8 CM3 Temperature: 15 ~ 35 OC
Humidity: 20 to 80% (relative), no condensation
0.35 ~ 500 nm (diameter) (0.35 ~ 1.1 nm only when using CO2) can be Absolutely: 1.2 x 10-4
TORR Relative: 1.5 x 10-7 P/P0
0.1 % (including the accuracy of the entire pressure measurement system, linear, hysteresis for full scale) 10-4 ~ 0.999 Integrated Type Detamination Station: 4
Temperature control: Two temperature rising zones, surrounding temperature ~ 425 OC
Available methods: Flow & vacuum removal, programmable multi -step heating profile
2% (implemented using authentication standard substance BAM P115) can be can be Rotary pump exhaust port, KF 16 Achievement vacuum 2.3 x 10-3 TORR 10 inch touch screen Port: 5 (3 for analysis, 1 for helium, removal gas/re -filling 1)
Purification: 99.999 % (HE, N2)
Input pressure: 8-10 psig
63
Measurement surface area/pole analysis device NOVA series that combines both speed and accuracy-Part Number-NOVA 800

NOVA 800

Available upon quote 0.5 Capacity: 2 L
Time: Up to 40 hours
N2, AR, CO2, other non -corrosion gas 20 or more (ASTM, USP, DIN, ISO) Four Ethernet 44 cm x 63 cm x 84 cm can be Supply: AC 100-240 V, 50 /60 Hz consumption: 345 VA (maximum) can be Equipment control: Up to 4 units
6 Language: English, French, German, Japanese, Chinese, Spanish
Stainless steel, viton elastomer 0.01 Vacuum volume measurement 1.2x10-8 CM3 Temperature: 15 ~ 35 OC
Humidity: 20 to 80% (relative), no condensation
0.35 ~ 500 nm (diameter) (0.35 ~ 1.1 nm only when using CO2) can be Absolutely: 1.2 x 10-4
TORR Relative: 1.5 x 10-7 P/P0
0.1 % (including the accuracy of the entire pressure measurement system, linear, hysteresis for full scale) 10-4 ~ 0.999 Integrated Type Detamination Station: 4
Temperature control: Two temperature rising zones, surrounding temperature ~ 425 OC
Available methods: Flow & vacuum removal, programmable multi -step heating profile
2% (implemented using authentication standard substance BAM P115) can be can be Rotary pump exhaust port, KF 16 Achievement vacuum 2.3 x 10-3 TORR 10 inch touch screen Port: 5 (3 for analysis, 1 for helium, removal gas/re -filling 1)
Purification: 99.999 % (HE, N2)
Input pressure: 8-10 psig
63

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Anton Paar GmbH


View more products of Anton Paar GmbH

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree