Price (excluding tax)
Estimate Required
Model Description
This optical meter, which is used to set the standard value in the industrial UV curing system, is not only possible to manipulate and collect data on the display screen of the measuring instrument, but also transfer illuminance profile to a computer for analysis. It can be used as a total.
■ Features
・ Measure and display the illuminance of high -output UV light sources at the same time
・ Select from 25 sampling per unit hour or 2,048/second
Model Filter
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Displayable maximum range
40W/cm2 | LEDCURE® Hikari Meterthermore
Measurement parameter
Integration, integrated light amount, irradiation profile | LEDCURE® Hikari Meterthermore
Integration, integrated light amount, illuminance profile, temperature profile | UV PowerMap® II + UV PowerView Software® III
Introduction light amount (J/cm2), peak illuminance (W/cm2) | Microcure® UV measuring instrument chip & data
Introduction light amount, peak illuminance | UVICURE®PLUS II
Introduction light amount, peak illuminance | UV Power Puck®Ⅱ
Introduction light amount, peak illuminance, irradiation profile
Introduction light amount, peak illuminance, irradiation profile | UV Power Puck® II & UV PUCK® II Profiler
Spectral responsiveness
L365: 340-392nm (half price, 50 nm; intersection ± 2nm), shielding outside the measurement band
L385: 360-412nm (half price, 50 nm; intersection ± 2nm), shielding outside the measurement band
L395: 370-422nm (half price, 50 nm; intersection ± 2nm), shielding outside the measurement band
L405: 380-432nm (half price, 50 nm; intersection ± 2nm), shielding outside the measurement band | LEDCURE® Hikari Meterthermore
4 Band: 320 ~ 390nm (UVA), 280 ~ 320nm (UVB), 250 ~ 260nm (UVC), 395 ~ 445nm (UVV) | UV PowerMap® II + UV PowerView Software® III
UVA (320 ~ 390nm) | Microcure® UV measuring instrument chip & data
1 channel continuous monitoring
Select one from UVA (320-390nm), UVB (280-320nm), UVC (250-260nm), and UVV (395-445nm) | UVICURE®PLUS II
4 channels continuous monitoring
[Standard specifications] UVA (320 ~ 390nm), UVB (280-320nm), UVC (250-260Nm), UVV (395-445nm) | UV Power Puck®Ⅱ
1 channel continuous monitoring
Select either from 320 ~ 390nm (UVA), 280-320nm (UVB), 250 ~ 260nm (UVC), 395 ~ 445nm (UVV).
4 channels continuous monitoring
[Standard specification]: 320 ~ 390nm (UVA), 280-320nm (UVB), 250-260nm (UVC), 395 ~ 445nm (UVV) | UV Power Puck® II & UV PUCK® II Profiler
size
117mm x 12.7mm (length x height) | LEDCURE® Hikari Meterthermore
13.8x5.3x1.27cm (LXDXH) | UV PowerMap® II + UV PowerView Software® III
・ UV measuring instrument chip: 33x24.13x6.35 mm (length x width x height)
・ Data leader: 139.7x108x36.8mm (horizontal x vertical x thick) | Microcure® UV measuring instrument chip & data
117mm (d) x12.7mm (H) | UVICURE®PLUS II
117mm (d) x12.7mm (H) | UV Power Puck®Ⅱ
117mm (d) x12.7mm (H)
117mm (d) x12.7mm (H) | UV Power Puck® II & UV PUCK® II Profiler
144mm (L) x63mm (W) x32mm (H) | NOBLE PROBE®
weight
289 | LEDCURE® Hikari Meterthermore
207 | UV PowerMap® II + UV PowerView Software® III
・ UV measuring instrument chip: 9.4g
・ Data leader: 333.1g | Microcure® UV measuring instrument chip & data
289 | UVICURE®PLUS II
289 | UV Power Puck®Ⅱ
289
289 | UV Power Puck® II & UV PUCK® II Profiler
165 | NOBLE PROBE®
Data output / display
Using UV PowerView Software® III, PC display (table and graph display can be displayed) | UV PowerMap® II + UV PowerView Software® III
Connect the UV measuring instrument chip to the data leader and read it on the LCD display | Microcure® UV measuring instrument chip & data
Digital display on the liquid crystal display | UVICURE®PLUS II
Digital display on the liquid crystal display | UV Power Puck®Ⅱ
Easy -to -read display of yellow characters on a black background, PC display with USB connection
Easy -to -read display of yellow characters on a black background, PC display with USB connection | UV Power Puck® II & UV PUCK® II Profiler
LCD digital display | NOBLE PROBE®
Range of operating
10W type (UVA): 500mw/cm2 ~ 10W/cm2
2W type (UVA): 100mw/cm2 ~ 2W/cm2
200MW type (UVA): 10mw/cm2 ~ 200MW/cm2 | Microcure® UV measuring instrument chip & data
Absolute calibration wavelength
365nm, 375nm, 385nm, 395nm, 405nm, 430nm | NOBLE PROBE®
Interface
USB connection | NOBLE PROBE®
Peripheral temperature
・ When operating -10 ℃ ~ 50 ℃
・ 5 ° C to 40 ℃ when saving | NOBLE PROBE®
accessories
USB cable, driver software, 1 optical instrument | NOBLE PROBE®
power supply
Two AA batteries | NOBLE PROBE®
See all 8 models in list
Part Number
Uvicure® Plus II & Uvicure® Plus II Profiler