Price (excluding tax)
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Current Programming Resolution
Current Readback Accuracy (MA)
Current Readback Resolution
Current Setting Accuracy (Ma)
Fall Time
LINE Regulation (MA)
LINE Regulation (MV)
LPP
Load Regulation (MA)
Load Regulation (MV)
Low AC Input Protection
NO LOAD
OCP Setting Accuracy
OCP Setting Range (A)
OTP
OVP Setting Accuracy
OVP Setting Range (V)
Output Channel (CH)
Power Ratio
R.M.S (MA)
RISING/FALLING VOLTAGE SLEW Rate (V/S)
RMS Ripple (MV)
Ratered Load
Ratered Output Current (a)
Ratered output voltage (v)
Remote Compensation Voltage
Ripple (PK to PK) (MV)
Ripple and Noise
Rise Time
Rising/Falling Current Slew Rate (A/S)
TOTAL RATED OUTPUT POWER (W)
Temperature Coofficient
Transment Response Time (MS)
VOLTAGE READBACK ACCURACY
Voltage Programming Accuracy
Voltage Programming Resolution
Voltage Readback Resolution
Part Number
SPS5044XHandling Company
Wave CrestItems marked with have different values depending on the model number.
Product Image | Price (excluding tax) | Current Programming Resolution | Current Readback Accuracy (MA) | Current Readback Resolution | Current Setting Accuracy (Ma) | Fall Time | LINE Regulation (MA) | LINE Regulation (MV) | LPP | Load Regulation (MA) | Load Regulation (MV) | Low AC Input Protection | NO LOAD | OCP Setting Accuracy | OCP Setting Range (A) | OTP | OVP Setting Accuracy | OVP Setting Range (V) | Output Channel (CH) | Power Ratio | R.M.S (MA) | RISING/FALLING VOLTAGE SLEW Rate (V/S) | RMS Ripple (MV) | Ratered Load | Ratered Output Current (a) | Ratered output voltage (v) | Remote Compensation Voltage | Ripple (PK to PK) (MV) | Ripple and Noise | Rise Time | Rising/Falling Current Slew Rate (A/S) | TOTAL RATED OUTPUT POWER (W) | Temperature Coofficient | Transment Response Time (MS) | VOLTAGE READBACK ACCURACY | Voltage Programming Accuracy | Voltage Programming Resolution | Voltage Readback Resolution |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Available upon quote | 1MA | 0.1%± 40 | 1MA | 0.1%± 30 | 90% ~ 10% of Ratered Output Voltage, Ratered Resistance Load | 40 | 18 (from 90 ~ 132vac or 170 ~ 265vac, Consant Load) | THE OVER POWER LIMIT IS APPROXIMATELY 105% of The Ratered Output Power. | 40 | 20 (FROM NOLOAD TO FULL LOAD, CONSTANT INPUT VOLTAGE) | Shut Off Output. | 50ms | ± (2% of Ratered Output Current) | 3-30 | Over Temperature Alarm and Shut Off Output. | ± (2% of Ratered Output Voltage) | 4 ~ 44 | 2 | 3.33 | 72 | 0.1 ~ 80 | 7 | 50ms | 30 | 40 | 0.6V | 60 | (NOISE BANDWIDTH 20MHz; Ripple Bandwidth 1MHz) | 10% ~ 90% of Ratered Output Voltage, Ratered Resistance Load | 0.01 ~ 60.00 | 720 | 100ppm/° C from Ratered Output Voltage Following 30-Minute Warm-UP. | 1 (Time for Recovery to within 0.1%+10mv of ITS RATED OUTPUT AGAINST CURRENT OF 50%~ 100%.) | 0.1%± 20 (MV) | 0.1%± 10 (MV) | 1MV | 1MV |