Product
Service sensor area setting type UST-30LCHandling Company
Hokuyo ElectricItems marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Angle Decomposition Ability | Angle decomposition ability | Current Consumption Current | Current consumption current | Design Life | Design life | Detachment Accuracy | Detachment accuracy | EXTERNAL DIMENSIONS (W × D × H) | External dimensions (W × D × H) | Impact Resistance | Impact resistance | Insulation Resistance | Insulation resistance | Material Body | Material Optical Window | Material body | Material optical window | Measurement and Decomposition Ability | Measurement and decomposition ability | Optical Electricity | Optical electricity | Peripheral term | Power ConsonSamption | Power-Supply Voltage | Power-supply voltage | Protective Structure | Protective structure | ROHS Directive | Repetition | Response Time / OFF | Response Time / ON | Response time / OFF | Response time / ON | Rohs Directive | START-UP TIME | Save Surrounding Temperature Humidity | Save surrounding temperature humidity | Scanning Angle | Scanning angle | Start-up time | Time of Scanning | Time of scanning | USed Peripheral Temperature Humidity | Used peripheral temperature humidity | interface | mass | power consumption |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
UST-30LC |
Available upon quote | 0.125 DEGREES | 0.125 degrees | TYP.150MA Below, But about 450MA is Required WHEN STARTING UP. | TYP.150mA below, but about 450mA is required when starting up. | 5 Years at Room Temperature | 5 years at room temperature | ± 40mm | ± 40mm | 50mm x 50mm x 70mm | 50mm x 50mm x 70mm | 196m/S2 (20g) X.Y.Z Direction 10 TIMES EACH | 196m/S2 (20g) x.y.z direction 10 times each | 10mΩ DS 500V Megger | 10mΩ DS 500V megger | Aluminum | Polycarbonate | Aluminum | Polycarbonate | 1mm Units | 1mm units | SEMICONDUCTOR LASER WAVELENGTH: 905NM FDA Laser Safety Class 1 | Semiconductor laser wavelength: 905NM FDA laser safety class 1 | 100,000LX or less | 3.6W or less | DC12V/DC24V | DC12V/DC24V | IP67 | IP67 | (EU) 2015/863 | σ <20mm | 66msec ~ 3241msec | 66msec ~ 3241msec | 66msec ~ 3241msec | 66msec ~ 3241msec | (EU) 2015/863 | Within 10sec | -30 ° C to +70 ° C 85 % RH or Less | -30 ° C to +70 ° C 85 % RH or less | 270 DEGREES | 270 degrees | Within 10sec | 25ms | 25ms | -30 ° C to +50 ℃ 85 % RH or Less | -30 ° C to +50 ℃ 85 % RH or less | Ethernet 100BASE-TX | 130g | 3.6W or less | |
UST-30LCN |
Available upon quote | 0.125 DEGREES | 0.125 degrees | TYP.150MA Below, But about 450MA is Required WHEN STARTING UP. | TYP.150mA below, but about 450mA is required when starting up. | 5 Years at Room Temperature | 5 years at room temperature | ± 40mm | ± 40mm | 50mm x 50mm x 70mm | 50mm x 50mm x 70mm | 196m/S2 (20g) X.Y.Z Direction 10 TIMES EACH | 196m/S2 (20g) x.y.z direction 10 times each | 10mΩ DC500V MEGGER | 10mΩ DC500V megger | Aluminum | Polycarbonate | Aluminum | Polycarbonate | 1mm Units | 1mm units | SEMICONDUCTOR LASER WAVELENGTH: 905NM FDA Laser Safety Class 1 | Semiconductor laser wavelength: 905NM FDA laser safety class 1 | 100,000LX or less | 3.6W or less | DC12V/DC24V | DC12V/DC24V | IP67 | IP67 | (EU) 2015/863 | σ <20mm | 66msec ~ 3241msec | 66msec ~ 3241msec | 66msec ~ 3241msec | 66msec ~ 3241msec | (EU) 2015/863 | Within 10sec | -30 ° C to +70 ° C 85 % RH or Less | -30 ° C to +70 ° C 85 % RH or less | 270 DEGREES | 270 degrees | Within 10sec | 25ms | 25ms | -30 ° C to +50 ℃ 85 % RH or Less | -30 ° C to +50 ℃ 85 % RH or less | Ethernet 100BASE-TX | 130g | 3.6W or less |
Click on the part number for more information about each product