Environmental test device Cosmopia constant heat tank standard series MHH type-EC-16MHHP
Environmental test device Cosmopia constant heat tank standard series MHH type-EC-26MHHP
Environmental test device Cosmopia constant heat tank standard series MHH type-EC-46MHHP
Environmental test device Cosmopia constant heat tank standard series MHH type-EC-86MHHP
Environmental test device Cosmopia constant heat tank standard series MHH type-EC-106MHHP
Environmental test device Cosmopia constant heat tank standard series MHH type-Satake Martimics Co., Ltd.

Environmental test device Cosmopia constant heat tank standard series MHH type
Satake Martimics Co., Ltd.


About This Product

Environmental test devices used in other fields such as semiconductors, electronic components, bios, etc. are required to be more functional for more advanced development and research. The heart is equipped with a scroll compressor that demonstrates efficiently and stable performance in the low range. Creating an essential test environment for improving the reliability of various products and experiments and research in food, chemistry, and medical fields. Features ■ Exterior design is renewed Stainless steel (SUS304) material is used for the exterior material, and a clear cover is attached to the center of the device to renew the design. ■ Equipped with scrolling compressor All models have a proven Hitachi scroll compressor for all models. ■ Digital temperature rising prevention tract We have changed to a conventional dial -type temperature rising device to adopt a digital temperature increase prevention device to improve setting operation and temperature accuracy. ■ Frozen cycle configuration parts 3 -year warranty The frozen cycle components will be guaranteed for three years so that you can use it with confidence. * Remodeled products of the frozen cycle are not applicable. * Limited to use in Japan. List of new functions ■ Frost defolder function It is a function to set the operation time and periodically defrost. When the temperature in the tank is less than 5 ° C, the temperature in the tank is heated up and defrosted. When the temperature in the tank is 5 degrees or more, stop the freezer and defrost it. ■ Humidification delay function When the temperature and humidity rise to prevent condensation to the sample, the dry spherical temperature reaches the prescribed temperature, then wait (1 to 120 minutes) and start humidification. ■ USB memory storage function You can save trend graph data to USB memory. This is a function to save the data (measured temperature, measurement humidity) displayed in the trend graph of the liquid crystal operation panel in a USB memory format format. ■ Data log function It is a function to save cycle data during operation in USB memory (cycle data). If an alarm is stopped due to an abnormal detection, it is a function to save the operation status of the device just before the stop in a USB memory. By recovering the data just before the stop, failure analysis is possible (backtress). ■ Driving mode selection function (selection of program steps) During program operation, it is possible to set the operation mode for each step. (Energy -saving mode / high load mode selection) You can change the device ability according to the test pattern, such as power tests.

  • Product

    Environmental test device Cosmopia constant heat tank standard series MHH type




*Please note that we may not be able to accommodate sample requests.

5 Models of Environmental test device Cosmopia constant heat tank standard series MHH type

Items marked with have different values ​​depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Electric characteristics maximum load current (A) Electrical characteristics power supply Equipment Examination tank dimension depth (mm) Examination tank dimension height (mm) Examination tank dimension width (mm) Exterior Product dimension depth (mm) Product dimension height (mm) Product dimension width (mm) Product mass (kg) Protective device Refrigerant Space temperature and humidity deviation 100.0 ° C or less (℃ /%RH) Space temperature and humidity deviation 100.1 ° C or higher (℃) Temperature and humidity fluctuation 100.0 ° C or less (℃ /%RH) Temperature and humidity fluctuations 100.1 ° C or higher (℃) Temperature change speed down Temperature change speed increased Temperature humidity gradient 100.0 ° C or less (℃ /%RH) Temperature humidity gradient 100.1 ° C or higher (℃) Temperature price arrival time falls Temperature price rising time increased Temperature range / humidity range (℃ /%RH) Test tank volume (L) accessories controller
Environmental test device Cosmopia constant heat tank standard series MHH type-Part Number-EC-16MHHP

EC-16MHHP

Available upon quote 18 Three -phase 200V 50/60Hz Observation window, Ksly hole, tank lamp, caster, level adjuster, USB port, RS-232C interface, etc. 380 630 500 Stainless steel plate (SUS430, hairline finish) 770 1,425 900 170 Electrical leakage breakers, control circuit fuse, overload protection device, high -pressure blocking device, temperature increase prevention device, empty heat prevention device, heated overcurrent protection device, etc. R404A 1.5 / 5 3 ± 0.3 / ± 2.5 ± 0.5 2.0 ° C / minute (131 ~ -21 ° C) 3.0 ° C / minute (-21 ~ 131 ℃) 3.0 / 10 Five Within 60 minutes (20 ~ -40 ° C) Within 50 minutes (20-150 ° C) -40 ~ 150 /20 ~ 98 120 Instruction manual, cable hole soft silicon plug / wick Driving mode: fixed price or program operation (Step: 20 steps / 1 pattern, repeated number: up to 98 times and infinite)
Environmental test device Cosmopia constant heat tank standard series MHH type-Part Number-EC-26MHHP

EC-26MHHP

Available upon quote 19 Three -phase 200V 50/60Hz Observation window, Ksly hole, tank lamp, caster, level adjuster, USB port, RS-232C interface, etc. 400 900 630 Stainless steel plate (SUS430, hairline finish) 770 1,695 1,030 210 Electrical leakage breakers, control circuit fuse, overload protection device, high -pressure blocking device, temperature increase prevention device, empty heat prevention device, heated overcurrent protection device, etc. R404A 1.5 / 5 3 ± 0.3 / ± 2.5 ± 0.5 2.0 ° C / minute (131 ~ -21 ° C) 3.0 ° C / minute (-21 ~ 131 ℃) 3.0 / 10 Five Within 60 minutes (20 ~ -40 ° C) Within 50 minutes (20-150 ° C) -40 ~ 150 /20 ~ 98 227 Instruction manual, cable hole soft silicon plug / wick Driving mode: fixed price or program operation (Step: 20 steps / 1 pattern, repeated number: up to 98 times and infinite)
Environmental test device Cosmopia constant heat tank standard series MHH type-Part Number-EC-46MHHP

EC-46MHHP

Available upon quote twenty two Three -phase 200V 50/60Hz Observation window, Ksly hole, tank lamp, caster, level adjuster, USB port, RS-232C interface, etc. 720 900 630 Stainless steel plate (SUS430, hairline finish) 1,090 1,695 1,030 300 Electrical leakage breakers, control circuit fuse, overload protection device, high -pressure blocking device, temperature increase prevention device, empty heat prevention device, heated overcurrent protection device, etc. R404A 1.5 / 5 3 ± 0.3 / ± 2.5 ± 0.5 2.0 ° C / minute (131 ~ -21 ° C) 3.0 ° C / minute (-21 ~ 131 ℃) 3.0 / 10 Five Within 50 minutes (20 ~ -40 ° C) Within 50 minutes (20-150 ° C) -40 ~ 150 /20 ~ 98 408 Instruction manual, cable hole soft silicon plug / wick Driving mode: fixed price or program operation (Step: 20 steps / 1 pattern, repeated number: up to 98 times and infinite)
Environmental test device Cosmopia constant heat tank standard series MHH type-Part Number-EC-86MHHP

EC-86MHHP

Available upon quote 35 Three -phase 200V 50/60Hz Observation window, Ksly hole, tank lamp, caster, level adjuster, USB port, RS-232C interface, etc. 800 1,000 1,000 Stainless steel plate (SUS430, hairline finish) 1,170 1,795 1,400 480 Electrical leakage breakers, control circuit fuse, overload protection device, high -pressure blocking device, temperature increase prevention device, empty heat prevention device, heated overcurrent protection device, etc. R404A 1.5 / 5 3 ± 0.3 / ± 2.5 ± 0.5 2.0 ° C / minute (131 ~ -21 ° C) 3.0 ° C / minute (-21 ~ 131 ℃) 3.0 / 10 Five Within 70 minutes (20 ~ -40 ° C) Within 50 minutes (20-150 ° C) -40 ~ 150 /20 ~ 98 800 Instruction manual, cable hole soft silicon plug / wick Driving mode: fixed price or program operation (Step: 20 steps / 1 pattern, repeated number: up to 98 times and infinite)
Environmental test device Cosmopia constant heat tank standard series MHH type-Part Number-EC-106MHHP

EC-106MHHP

Available upon quote 35 Three -phase 200V 50/60Hz Observation window, Ksly hole, tank lamp, caster, level adjuster, USB port, RS-232C interface, etc. 1,000 1,000 1,000 Stainless steel plate (SUS430, hairline finish) 1,370 1,795 1,400 550 Electrical leakage breakers, control circuit fuse, overload protection device, high -pressure blocking device, temperature increase prevention device, empty heat prevention device, heated overcurrent protection device, etc. R404A 2.0 / 10 3 ± 0.3 / ± 2.5 ± 0.5 1.5 ° C / minute (131 ~ -21 ° C) 3.0 ° C / minute (-21 ~ 131 ℃) 4.0 / 10 Five Within 90 minutes (20 ~ -40 ° C) Within 65 minutes (20-150 ° C) -40 ~ 150 /20 ~ 98 1,000 Instruction manual, cable hole soft silicon plug / wick Driving mode: fixed price or program operation (Step: 20 steps / 1 pattern, repeated number: up to 98 times and infinite)

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Satake Martimics Co., Ltd.


View more products of Satake Martimics Co., Ltd.

About Company Handling This Product

Satake Martimics Co., Ltd.

  • Japan
  • Since 1920
  • 200 employees

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree