Out gas analysis system thermos -electric element (Peltier element) control type 4ch / 1ch analysis system-PSA-QS-1001
Out gas analysis system thermos -electric element (Peltier element) control type 4ch / 1ch analysis system-NIHON DEMPA KOGYO CO., LTD.

Out gas analysis system thermos -electric element (Peltier element) control type 4ch / 1ch analysis system
NIHON DEMPA KOGYO CO., LTD.


About This Product

Feature ■ Since liquid nitrogen is not used, it is possible to evaluate it with a simple system and is ideal for materials and environmental evaluation. ・ Running cost is basically only for power expenses. ・ Measurement is possible at low temperature (-80 ° C to+125 ° C) and high-frame vapor (10-4 PA or less). ・ The type that can be measured with up to four sensor mag is a type that can be evaluated by up to four sensor sides, and a type that is ideal for evaluation in a small vacuum chamber measured by one sensor journey. there is. ■ Measurement sample can be measured as it is without gasization. ・ It is possible to collect it as it is without destroying the sample. ・ There are no sample size restrictions, and out -gas measurement in the final product state is possible. ■ Out gas measurement is possible in real time for a long time. ・ By placing up to four modules and measuring for a long time, it is possible to identify out -gas occurrence and occurrence time. ・ The measurement interval can be selected from 1, 10, 30, 60, 600, 3,600 seconds. ・ Measurement data is divided and saved every week. It is possible to prevent data enlargement. ■ It is possible to cool down to -80 ° C or less depending on the heat dissipation conditions. By cooling the sensor moulic mounting part (heat release surface) to -30 ° C, the crystal vibration sensor can be cooled below -80 ° C.

  • Product

    Out gas analysis system thermos -electric element (Peltier element) control type 4ch / 1ch analysis system




*Please note that we may not be able to accommodate sample requests.

2 Models of Out gas analysis system thermos -electric element (Peltier element) control type 4ch / 1ch analysis system

Items marked with have different values ​​depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Frequency detection accuracy Frequency dissolution ability Number of control CH Operating temperature range Power-supply voltage size weight
Out gas analysis system thermos -electric element (Peltier element) control type 4ch / 1ch analysis system-Part Number-PSA-QS-1001

PSA-QS-1001

Available upon quote ≦ 1ppm 0.01Hz 1 to 4 10 ~ 40 ℃ ' AC100V ~ AC240V (50/60Hz) 437 (W) x 132 (H) x 499 (d) mm (excluding protrusion) ≦ 10kg
Out gas analysis system thermos -electric element (Peltier element) control type 4ch / 1ch analysis system-Part Number-PSA-QS-1002

PSA-QS-1002

Available upon quote ≦ 1ppm 0.01Hz 1 10 ~ 40 ℃ ' AC100V ~ AC240V (50/60Hz) 437 (W) x 132 (H) x 499 (d) mm (excluding protrusion) ≦ 10kg

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of NIHON DEMPA KOGYO CO., LTD.


View more products of NIHON DEMPA KOGYO CO., LTD.

About Company Handling This Product

NIHON DEMPA KOGYO CO., LTD.

  • Japan
  • Since 1948
  • 2,378 employees

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree