Out gas analysis system thermos-electric element (Peltier element) Control type 4ch / 1ch analysis system PSA-QM-1002
NIHON DEMPA KOGYO CO., LTD.
About This Product
Feature
■ Since liquid nitrogen is not used, it is possible to evaluate it with a simple system and is ideal for materials and environmental evaluation.
The running cost is basically only for electricity. It is possible to measure at low temperature (-80 ° C to+125 ° C) and high-framed (10-4 PA or less). There are a type that is ideal for evaluation with a large vacuum chamber that can measure up to four sensor duises of the resolute gas generated from the sample, and the type that is ideal for evaluation with a small vacuum chamber measured with one sensor magic. 。
■ Measurement sample can be measured as it is without gasization.
It can be collected as it is without destroying the sample. There is no sample size restriction, and out -gas measurement in the final product state is possible.
■ Out gas measurement is possible in real time for a long time.
・ By placing up to four modules and measuring for a long time, it is possible to identify out -gas occurrence and occurrence time.
・ The measurement interval can be selected from 1, 10, 30, 60, 600, 3,600 seconds.
・ Measurement data is divided and saved every week. It is possible to prevent data enlargement.
■ It is possible to cool down to -80 ° C or less depending on the heat dissipation conditions.
By cooling the sensor moulic mounting part (heat release surface) to -30 ° C, the crystal vibration sensor can be cooled below -80 ° C.
4ch analysis system
◼ It can be installed in a large vacuum chamber
LVDS*is used as an output interface. Sensor journey and sensing unit can be installed up to 20m up to 20m.
1ch analysis system
◼ Ideal for evaluation with a small vacuum chamber as an inexpensive entry model
-The number of connected sensor modes is one, ideal for environmental evaluation of small vacuum chamber.
・ Material analysis evaluation is possible with a cheap configuration by combining with a small vacuum chamber for material evaluation.
-The reproducibility of out -gas is high, high -precision and highly stable measurement is possible.
◼ ︎ Crystal vibration sensor replacement in sensor modes is possible
The crystal vibration sensor in the sensor modes contaminated by out -gas measurement must be replaced because it is a consumable item. It is possible to replace it easily on the customer side.
-
-
Product
Out gas analysis system thermos-electric element (Peltier element) Control type 4ch / 1ch analysis system PSA-QM-1002