Type with linear motor core τ Linear NLA-MA/Na type-NLA-250MAMA
Type with linear motor core τ Linear NLA-MA/Na type-CKD Nisshin Electrical Corporation Co., Ltd.

Type with linear motor core τ Linear NLA-MA/Na type
CKD Nisshin Electrical Corporation Co., Ltd.


About This Product

■ A wealth of lineup according to the application Coreless, core NLA series: Rated thrust 7N (coreless) ~ 1,500 (with core) lineup lineup ■ Characteristics ・ Core type NLA-MA type ・ Core type NLA-NA type The thrust density is high and you can get a large thrust (up to 4,500N). High rigidity of the motor drive portion is ideal for high -speed positioning of large amounts of load. ■ Water -cooled and air -cooled support is possible A water -cooled and air cold type is possible with exclusive correspondence. ■ Scale Leslinia Sensor is possible You can detect the position without using the linear scale. Ideal for long stroke transportation applications. ■ Various linear encoder can be selected You can select a linear encoder according to the resolution, speed, usage environment, etc. ・ Renish show encoder Open Type Absolute Encoder [Resolute Series (communication specification: BISS)], Open Type Inclumental Encoder [Tonic Series] ・ Mitotoyo encoder Open Type Absolute Encoder [ST708 type (communication specification: ENSIS)], Assemblitimate InCrimination Encoder [AT211 type] ・ CKD Nikkora Denki Society Scaleslinia Sensor ・ Heiden Hein Encoder (Customer available) Although the hyden high encoder is not handled by the Company, there are models that can be connected to our servo driver by customer. ■ It is also possible to build an X/XY/XTθ stage equipped with linear In addition to the X/XY stage, it is also possible to build an XYθ stage equipped with a high -performance direct drive motor τdisc. ■ Common specifications Installation location: Indoor use. Do not install in harmful atmosphere such as corrosion gas, grinding oil, metal powder, and oil. ■ Calculation of required magnet base length τ Please select the magnet base of the linear according to the following calculation method. [Total magnet base length ≧ maximum movable length+coil unit total length+magnetic policy sensor required length]

  • Product

    Type with linear motor core τ Linear NLA-MA/Na type




*Please note that we may not be able to accommodate sample requests.

6 Models of Type with linear motor core τ Linear NLA-MA/Na type

Items marked with have different values ​​depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Approximately used humidity Coil unit mass Coil unit type CLM Impact resistance Insulated pressure Insulating class Magnet -based type MBMA Magnet base mass kg Magnetic suction power Maximum speed Maximum thrust N Mounting direction Power supply voltage specification ACV Rated current Rated output Rated thrust Used peripheral temperature (℃) Vibration resistance cooling method elevation
Type with linear motor core τ Linear NLA-MA/Na type-Part Number-NLA-250MAMA

NLA-250MAMA

Available upon quote 85%or less without condensation 3 250ma 5g (3 times each 3 times) AC1,500V, 1 minute F's F Select from 64a (64mm) /256A (256mm) 64a: 0.5/256A: 1.7 3000 2.5 725 (625) Horizontal, vertical 200 3.4 500 250 0 ~ 40 1G (3 direction 2H) Natural air cooling 1,000m or less
Type with linear motor core τ Linear NLA-MA/Na type-Part Number-NLA-500MAMA

NLA-500MAMA

Available upon quote 85%or less without condensation 6 500ma 5g (3 times each 3 times) AC1,500V, 1 minute F's F Select from 64a (64mm) /256A (256mm) 64a: 0.5/256A: 1.7 6000 2.5 1,250 Horizontal, vertical 200 6.8 1000 500 0 ~ 40 1G (3 direction 2H) Natural air cooling 1,000m or less
Type with linear motor core τ Linear NLA-MA/Na type-Part Number-NLA-750MAMA

NLA-750MAMA

Available upon quote 85%or less without condensation 9 750ma 5g (3 times each 3 times) AC1,500V, 1 minute F's F Select from 64a (64mm) /256A (256mm) 64a: 0.5/256A: 1.7 9000 2.5 2,250 Horizontal, vertical 200 10.2 1500 750 0 ~ 40 1G (3 direction 2H) Natural air cooling 1,000m or less
Type with linear motor core τ Linear NLA-MA/Na type-Part Number-NLA-500Nama

NLA-500Nama

Available upon quote 85%or less without condensation 5.5 500ma 5g (3 times each 3 times) AC1,500V, 1 minute F's F Select from 64a (64mm) /256A (256mm) 64a: 0.5/256A: 1.7 6000 3 1,250 Horizontal, vertical 200 6.8 1250 500 0 ~ 40 1G (3 direction 2H) Natural air cooling 1,000m or less
Type with linear motor core τ Linear NLA-MA/Na type-Part Number-NLA-1000nama

NLA-1000nama

Available upon quote 85%or less without condensation 11 1000ma 5g (3 times each 3 times) AC1,500V, 1 minute F's F Select from 64a (64mm) /256A (256mm) 64a: 0.5/256A: 1.7 12000 3 3,000 (2,500) Horizontal, vertical 200 14 2500 1000 0 ~ 40 1G (3 direction 2H) Natural air cooling 1,000m or less
Type with linear motor core τ Linear NLA-MA/Na type-Part Number-NLA-1500Nama

NLA-1500Nama

Available upon quote 85%or less without condensation 17 150ma 5g (3 times each 3 times) AC1,500V, 1 minute F's F Select from 64a (64mm) /256A (256mm) 64a: 0.5/256A: 1.7 18000 3 4,500 Horizontal, vertical 200 twenty one 3750 1500 0 ~ 40 1G (3 direction 2H) Natural air cooling 1,000m or less

Click on the part number for more information about each product