Product
Measurement of real -time dissolved oxygen (do) on the production line OXYHandling Company
Anton Paar GmbHItems marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Accuracy of gas phase (value for larger) | CIP/SIP temperature | Dimensions (height x width x depth) | Line pressure | Liquid accuracy (value for larger) | Measurement interval | Measurement range (dissolved in liquid) | Measurement range (gas phase in CO2) | Peripheral temperature / humidity | Sample temperature (non -freezing) | certification | power supply |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
OXY 4100 |
Available upon quote |
A trace range: ≤ ± 25ppmv or ± 3% Wide range: ≦ ± 0.1%₂ or ± 3% |
Up to 12 BAR (absolute pressure), up to 5 BAR (absolute pressure) in gas phase measurement | 162x162x215 / CO₂ Purity Monitor's pressure sensor: 80x80x120 | Up to 12 BAR (absolute pressure), up to 5 BAR (absolute pressure) in gas phase measurement |
Trace range: ≤ 1 ppb or ± 3 % Wide range: ≤ ± 0.042 PPM or ± 3 % |
1 to 360 seconds (oxy 4,100: 15 seconds) |
A trace range: 0 to 2,000 ppb Wide range: 0 to 22.5ppm |
A trace range: 0 ~ 4.2 % O₂ Wide range: 0 to 50 % O₂ |
-5 ~+50 ° C / 0 ~ 90 % RH (no condensation) |
Ultra microwave oven: 0 to 40 ℃ A trace range: -5 ° C ~+65 ℃ Wide range: -5 ℃ ~+65 ℃ Super wide range: -5 ~+40 ℃ |
- | SELV DC 24 V (DC 20 ~ 30 V), up to 1.6 W | |
OXY 5100 |
Available upon quote |
Ultra microwave: ≤ 2ppmv or ± 5% A trace range: ≤ ± 25ppmv or ± 3% Wide range: ≦ ± 0.1%₂ or ± 3% Super wide range: ≦ ± 0.2%O₂ or ± 5% |
A trace range, wide range, super wide range: up to 99 ° C, up to 130 ° C (up to 30 minutes) | 162x162x215 / CO₂ Purity Monitor's pressure sensor: 80x80x120 | Up to 12 BAR (absolute pressure), up to 5 BAR (absolute pressure) in gas phase measurement |
Ultra-microwave:- Trace range: ≤ 1 ppb or ± 3 % Wide range: ≤ ± 0.042 PPM or ± 3 % Super wide range: ≤ ± 0.1 ppm or ± 5 % |
1 to 360 seconds (oxy 4,100: 15 seconds) |
Ultra microwave oven:- (gas only) A trace range: 0 to 2,000 ppb Wide range: 0 to 22.5ppm Super wide range: 0 ~ 45ppm |
Ultra microwave oven: 0 to 200 ppmv A trace range: 0 ~ 4.2 % O₂ Wide range: 0 to 50 % O₂ Super wide range: 0 ~ 100 % O₂ |
-5 ~+50 ° C / 0 ~ 90 % RH (no condensation) |
Ultra microwave oven: 0 to 40 ℃ A trace range: -5 ° C ~+65 ℃ Wide range: -5 ℃ ~+65 ℃ Super wide range: -5 ~+40 ℃ |
A trace range EHEDG (Type El-Class I) Wide range EHEDG (Type El-Class I) Super wide range EHEDG (Type El-Class I) |
SELV DC 24 V (DC 20 ~ 30 V), up to 1.6 W |
Click on the part number for more information about each product