Measurement of real -time dissolved oxygen (do) on the production line OXY-OXY 4100
Measurement of real -time dissolved oxygen (do) on the production line OXY-Anton Paar GmbH

Measurement of real -time dissolved oxygen (do) on the production line OXY
Anton Paar GmbH


About This Product

Measure real -time dissolved oxygen (do) on the production line. This sensor performs accurate, drift -free measurement in the manufacturing process. CO₂ Purity Monitor is a compact system that monitors O₂ content in the pressurized CO2 collection jurisdiction. ■ Inline oxygen sensor. No calibration on site with a smart sensor cap The sensor cap realizes a smart connection between the sensor and the samples. You can choose the optimal sensor cap according to the application. You can easily switch the range just by replacing the sensor cap. All required calibration parameters are installed on the sensor cap. Toolmaster® technology automatically detects sensor caps and transferring all setting parameters to sensors. After attaching the cap, you can start the inline measurement immediately. ■ Hygiene design - EHEDG certified, SIP compatible The OXY 4100 /5100 is designed to be washed and sterilized at a maximum temperature of 130 ° C. In just a few minutes after cleaning and sterilization, it can be operated in specifications, minimizing downtime. ■ Start use by turning on power -Maximum performance with simple settings No special training is required for the operation and setting of the device. The OXY 5100 can be easily set using PICO 3000 software, the touch screen interface of the built -in display conversion machine, or using the MPDS 5 display conversion machine. The OXY 5100 can be easily selected according to the desired communication specifications, such as analog output (4-20 ma), modbus RTU, modbus TCP, mass, proofinet IO, Ethernet/IP, etc. The OXY 4100 transmitter has an analog output and a touch screen interface.

  • Product

    Measurement of real -time dissolved oxygen (do) on the production line OXY




*Please note that we may not be able to accommodate sample requests.

2 Models of Measurement of real -time dissolved oxygen (do) on the production line OXY

Items marked with have different values ​​depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Accuracy of gas phase (value for larger) CIP/SIP temperature Dimensions (height x width x depth) Line pressure Liquid accuracy (value for larger) Measurement interval Measurement range (dissolved in liquid) Measurement range (gas phase in CO2) Peripheral temperature / humidity Sample temperature (non -freezing) certification power supply
Measurement of real -time dissolved oxygen (do) on the production line OXY-Part Number-OXY 4100

OXY 4100

Available upon quote A trace range: ≤ ± 25ppmv or ± 3%
Wide range: ≦ ± 0.1%₂ or ± 3%
Up to 12 BAR (absolute pressure), up to 5 BAR (absolute pressure) in gas phase measurement 162x162x215 / CO₂ Purity Monitor's pressure sensor: 80x80x120 Up to 12 BAR (absolute pressure), up to 5 BAR (absolute pressure) in gas phase measurement Trace range: ≤ 1 ppb or ± 3 %
Wide range: ≤ ± 0.042 PPM or ± 3 %
1 to 360 seconds (oxy 4,100: 15 seconds) A trace range: 0 to 2,000 ppb
Wide range: 0 to 22.5ppm
A trace range: 0 ~ 4.2 % O₂
Wide range: 0 to 50 % O₂
-5 ~+50 ° C / 0 ~ 90 % RH (no condensation) Ultra microwave oven: 0 to 40 ℃
A trace range: -5 ° C ~+65 ℃
Wide range: -5 ℃ ~+65 ℃
Super wide range: -5 ~+40 ℃
- SELV DC 24 V (DC 20 ~ 30 V), up to 1.6 W
Measurement of real -time dissolved oxygen (do) on the production line OXY-Part Number-OXY 5100

OXY 5100

Available upon quote Ultra microwave: ≤ 2ppmv or ± 5%
A trace range: ≤ ± 25ppmv or ± 3%
Wide range: ≦ ± 0.1%₂ or ± 3%
Super wide range: ≦ ± 0.2%O₂ or ± 5%
A trace range, wide range, super wide range: up to 99 ° C, up to 130 ° C (up to 30 minutes) 162x162x215 / CO₂ Purity Monitor's pressure sensor: 80x80x120 Up to 12 BAR (absolute pressure), up to 5 BAR (absolute pressure) in gas phase measurement Ultra-microwave:-
Trace range: ≤ 1 ppb or ± 3 %
Wide range: ≤ ± 0.042 PPM or ± 3 %
Super wide range: ≤ ± 0.1 ppm or ± 5 %
1 to 360 seconds (oxy 4,100: 15 seconds) Ultra microwave oven:- (gas only)
A trace range: 0 to 2,000 ppb
Wide range: 0 to 22.5ppm
Super wide range: 0 ~ 45ppm
Ultra microwave oven: 0 to 200 ppmv
A trace range: 0 ~ 4.2 % O₂
Wide range: 0 to 50 % O₂
Super wide range: 0 ~ 100 % O₂
-5 ~+50 ° C / 0 ~ 90 % RH (no condensation) Ultra microwave oven: 0 to 40 ℃
A trace range: -5 ° C ~+65 ℃
Wide range: -5 ℃ ~+65 ℃
Super wide range: -5 ~+40 ℃
A trace range EHEDG (Type El-Class I)
Wide range EHEDG (Type El-Class I)
Super wide range EHEDG (Type El-Class I)
SELV DC 24 V (DC 20 ~ 30 V), up to 1.6 W

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Anton Paar GmbH


View more products of Anton Paar GmbH

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree