Temperature Data Logar Teflon Prove HITEMP140-FP SeriesHandling Company
Krone Co., Ltd.Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Battery life | Battery used | Cord surface material | Material | Measurement accuracy | Measurement interval | Measurement start mode | Measurement temperature range | Memory number | Probe size | Proofreading | Real -time measurement | Sensor code length | Temperature sensor | Usage environment pressure | Used environment humidity | Used environment temperature | data form | graph display | resolution | software | weight |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
HITEMP140-FP-6 |
Available upon quote | About two years | 3.6V lithium battery (possible with battery replacement users) | PFA | SUS316 PTFE | ± 0.1 ℃ (+20 ~+140 ° C) | Select once every four to 24 hours per second | Measurement start with analysis software or measurement start setting can be set up after up to 18 months | -60 ~+260 ° C | 65,536 memory | 152mm | Automatic record date for digital calibration with analysis software | Automatically record the date and time and temperature by connecting to the computer | 914 mm or 1829 mm selection | Shirokane resistor Pt 100Ω, ø 2.5 mm | 0.1379 (under vacuum) ~ 6,896 MBAR (low pressure) | 100%RH (complete waterproof IP68 compatible) | -40 ~+140 ° C | Record the temperature over the date and time. Various temperature units can be changed | Display from one graph to all graphs | 0.01 ℃ | Compatible with Windows XP SP3 | Approximately 85 g | |
HITEMP140-FP-12 |
Available upon quote | About two years | 3.6V lithium battery (possible with battery replacement users) | PFA | SUS316 PTFE | ± 0.1 ℃ (+20 ~+140 ° C) | Select once every four to 24 hours per second | Measurement start with analysis software or measurement start setting can be set up after up to 18 months | -60 ~+260 ° C | 65,536 memory | 305mm | Automatic record date for digital calibration with analysis software | Automatically record the date and time and temperature by connecting to the computer | 914 mm or 1829 mm selection | Shirokane resistor Pt 100Ω, ø 2.5 mm | 0.1379 (under vacuum) ~ 6,896 MBAR (low pressure) | 100%RH (complete waterproof IP68 compatible) | -40 ~+140 ° C | Record the temperature over the date and time. Various temperature units can be changed | Display from one graph to all graphs | 0.01 ℃ | Compatible with Windows XP SP3 | Approximately 85 g | |
HITEMP140-FP-24 |
Available upon quote | About two years | 3.6V lithium battery (possible with battery replacement users) | PFA | SUS316 PTFE | ± 0.1 ℃ (+20 ~+140 ° C) | Select once every four to 24 hours per second | Measurement start with analysis software or measurement start setting can be set up after up to 18 months | -60 ~+260 ° C | 65,536 memory | 609mm | Automatic record date for digital calibration with analysis software | Automatically record the date and time and temperature by connecting to the computer | 914 mm or 1829 mm selection | Shirokane resistor Pt 100Ω, ø 2.5 mm | 0.1379 (under vacuum) ~ 6,896 MBAR (low pressure) | 100%RH (complete waterproof IP68 compatible) | -40 ~+140 ° C | Record the temperature over the date and time. Various temperature units can be changed | Display from one graph to all graphs | 0.01 ℃ | Compatible with Windows XP SP3 | Approximately 85 g | |
HITEMP140-FP-36 |
Available upon quote | About two years | 3.6V lithium battery (possible with battery replacement users) | PFA | SUS316 PTFE | ± 0.1 ℃ (+20 ~+140 ° C) | Select once every four to 24 hours per second | Measurement start with analysis software or measurement start setting can be set up after up to 18 months | -60 ~+260 ° C | 65,536 memory | 914mm | Automatic record date for digital calibration with analysis software | Automatically record the date and time and temperature by connecting to the computer | 914 mm or 1829 mm selection | Shirokane resistor Pt 100Ω, ø 2.5 mm | 0.1379 (under vacuum) ~ 6,896 MBAR (low pressure) | 100%RH (complete waterproof IP68 compatible) | -40 ~+140 ° C | Record the temperature over the date and time. Various temperature units can be changed | Display from one graph to all graphs | 0.01 ℃ | Compatible with Windows XP SP3 | Approximately 85 g | |
HITEMP140-FP-72 |
Available upon quote | About two years | 3.6V lithium battery (possible with battery replacement users) | PFA | SUS316 PTFE | ± 0.1 ℃ (+20 ~+140 ° C) | Select once every four to 24 hours per second | Measurement start with analysis software or measurement start setting can be set up after up to 18 months | -60 ~+260 ° C | 65,536 memory | 1829mm | Automatic record date for digital calibration with analysis software | Automatically record the date and time and temperature by connecting to the computer | 914 mm or 1829 mm selection | Shirokane resistor Pt 100Ω, ø 2.5 mm | 0.1379 (under vacuum) ~ 6,896 MBAR (low pressure) | 100%RH (complete waterproof IP68 compatible) | -40 ~+140 ° C | Record the temperature over the date and time. Various temperature units can be changed | Display from one graph to all graphs | 0.01 ℃ | Compatible with Windows XP SP3 | Approximately 85 g |