Product
Ultra -small, general -purpose digital output type DLC seriesHandling Company
Krone Co., Ltd.Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Compensation temperature range | Destruction pressure | Drive voltage | Humidity | Measurement accuracy | Measuring category | Operating temperature range | Overload pressure | Pressure range | Rated pressure range | Save temperature range | output | type |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DLC-L01D |
Available upon quote | -25 ℃ ~ 85 ℃ | 300 INH2O 74.65 kpa | 1.8V ~ 3.6V | 0 ~ 95% RH | ± 1.00%FSS ~ | Gauge pressure, differential pressure, absolute pressure | -40 ℃ ~ 85 ℃ | 100 INH2O 24.88 kpa | ± 250pa ~ ± 1MPa, 0-250Pa ... 1MPa | ± 1 inH2O 248.84 PA | -40 ℃ ~ 125 ℃ | I2C (16bit) | low pressure | |
DLC-L02D |
Available upon quote | -25 ℃ ~ 85 ℃ | 300 INH2O 74.65 kpa | 1.8V ~ 3.6V | 0 ~ 95% RH | ± 1.00%FSS ~ | Gauge pressure, differential pressure, absolute pressure | -40 ℃ ~ 85 ℃ | 100 INH2O 24.88 kpa | ± 250pa ~ ± 1MPa, 0-250Pa ... 1MPa | ± 2 INH2O 497.68 PA | -40 ℃ ~ 125 ℃ | I2C (16bit) | low pressure | |
DLC-L05D |
Available upon quote | -25 ℃ ~ 85 ℃ | 300 INH2O 74.65 kpa | 1.8V ~ 3.6V | 0 ~ 95% RH | ± 1.00%FSS ~ | Gauge pressure, differential pressure, absolute pressure | -40 ℃ ~ 85 ℃ | 200 INH2O 49.77 kpa | ± 250pa ~ ± 1MPa, 0-250Pa ... 1MPa | ± 5 INH2O 1,244.20 PA | -40 ℃ ~ 125 ℃ | I2C (16bit) | low pressure | |
DLC-L10D |
Available upon quote | -25 ℃ ~ 85 ℃ | 300 INH2O 74.65 kpa | 1.8V ~ 3.6V | 0 ~ 95% RH | ± 1.00%FSS ~ | Gauge pressure, differential pressure, absolute pressure | -40 ℃ ~ 85 ℃ | 200 INH2O 49.77 kpa | ± 250pa ~ ± 1MPa, 0-250Pa ... 1MPa | ± 10 INH2O 2,488.40 PA | -40 ℃ ~ 125 ℃ | I2C (16bit) | low pressure | |
DLC-L20d |
Available upon quote | -25 ℃ ~ 85 ℃ | 500 inH2O 124.42 kpa | 1.8V ~ 3.6V | 0 ~ 95% RH | ± 1.00%FSS ~ | Gauge pressure, differential pressure, absolute pressure | -40 ℃ ~ 85 ℃ | 200 INH2O 49.77 kpa | ± 250pa ~ ± 1MPa, 0-250Pa ... 1MPa | ± 20 INH2O 4,976.80 PA | -40 ℃ ~ 125 ℃ | I2C (16bit) | low pressure | |
DLC-L30D |
Available upon quote | -25 ℃ ~ 85 ℃ | 500 inH2O 124.42 kpa | 1.8V ~ 3.6V | 0 ~ 95% RH | ± 1.00%FSS ~ | Gauge pressure, differential pressure, absolute pressure | -40 ℃ ~ 85 ℃ | 200 INH2O 49.77 kpa | ± 250pa ~ ± 1MPa, 0-250Pa ... 1MPa | ± 30 INH2O 7,465.20 PA | -40 ℃ ~ 125 ℃ | I2C (16bit) | low pressure | |
DLC-L60D |
Available upon quote | -25 ℃ ~ 85 ℃ | 800 inh2o 199.01 kpa | 1.8V ~ 3.6V | 0 ~ 95% RH | ± 1.00%FSS ~ | Gauge pressure, differential pressure, absolute pressure | -40 ℃ ~ 85 ℃ | 200 INH2O 49.77 kpa | ± 250pa ~ ± 1MPa, 0-250Pa ... 1MPa | ± 60 inh2o 14,930.4 PA | -40 ℃ ~ 125 ℃ | I2C (16bit) | low pressure | |
DLC-L01G |
Available upon quote | -25 ℃ ~ 85 ℃ | 300 INH2O 74.65 kpa | 1.8V ~ 3.6V | 0 ~ 95% RH | ± 1.00%FSS ~ | Gauge pressure, differential pressure, absolute pressure | -40 ℃ ~ 85 ℃ | 100 INH2O 24.88 kpa | ± 250pa ~ ± 1MPa, 0-250Pa ... 1MPa | 0 to 1 inh2o 248.84 PA | -40 ℃ ~ 125 ℃ | I2C (16bit) | low pressure | |
DLC-L02G |
Available upon quote | -25 ℃ ~ 85 ℃ | 300 INH2O 74.65 kpa | 1.8V ~ 3.6V | 0 ~ 95% RH | ± 1.00%FSS ~ | Gauge pressure, differential pressure, absolute pressure | -40 ℃ ~ 85 ℃ | 100 INH2O 24.88 kpa | ± 250pa ~ ± 1MPa, 0-250Pa ... 1MPa | 0 to 2 inh2o 497.68 PA | -40 ℃ ~ 125 ℃ | I2C (16bit) | low pressure | |
DLC-L05G |
Available upon quote | -25 ℃ ~ 85 ℃ | 300 INH2O 74.65 kpa | 1.8V ~ 3.6V | 0 ~ 95% RH | ± 1.00%FSS ~ | Gauge pressure, differential pressure, absolute pressure | -40 ℃ ~ 85 ℃ | 200 INH2O 49.77 kpa | ± 250pa ~ ± 1MPa, 0-250Pa ... 1MPa | 0 to 5 INH2O 1,244.20 PA | -40 ℃ ~ 125 ℃ | I2C (16bit) | low pressure |
Click on the part number for more information about each product