Product
Small but high heating performance stationary reflow device RDT-250ECHandling Company
MalcomCategories
Product Image | Part Number | Price (excluding tax) | Board tray | Device dimensions | Device weight | External gas | Heating method | Heating on the lower side | Measured score | Measuring temperature | Nitrogen supply function | Oxygen concentration in the furnace (when using nitrogen) | Target board | Temperature precision | Upper surface heating | control | cooling method | power supply |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RDT-250EC |
Available upon quote | Internet or career type (selection) | 778W × 860.5D × 1,417h (including signal tower) | Approximately 210kg | 0.3 ~ 0.5MPa 100L / min (MAX) |
Up: Passion / far -infrared radiation Below: Far infrared radiation (option) |
Options (Far infrared heater: about 2.4kw (400W x 6)) | 6 points (automatic mode: 7 points) | At room temperature ~ 400 ℃ | Flow rate adjustment valve: 100L / min | At least 100ppm |
250W x 330lmm or less Height: When setting the lower limit of carrier bar: 5mm lower 28mm upper limit: Lower 31mm upper 2mm * Dimensions from the bottom of the substrate |
Room temperature ~ 80 ° C: ± 3 ° C 80 ° C ~ 330 ° C: ± 2 ° C 300 ° C ~ 400 ° C: ± 3 ℃ |
Hot air / far infrared heterer: 7.2kW (about 240W x 30 blocks) * Deviation can be set for reference modules |
Built -in PC (including dedicated software) Profile creation / data analysis: RDT-250ECS (corresponding OS: Windows10, PC is required separately) |
Auto cooling by introducing external gas (nitrogen or air) With a cooling flow rate adjustment valve |
3 -phase 200V 50/60Hz 8KVA (when adding options lower heaters: 10.4kva) |