Excellent economic Walkem Controller P100/W100 SeriesHandling Company
IWAKI CO., LTD.Categories
Usage Scenarios
Environment & Recycling Use / Food Industry Use / Electronics & Electrical UseItems marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Input digital input | Input temperature input | Measured electromagnetic power conducting | Measured low -speed flow volume meter -in -flow rate | Measurement 2 electrode -type power conducting | Measurement PH | Measurement high -speed flow meter integrated flow rate | Measurement orp | Measuring temperature | Output analog output | Output relay output | Power-supply voltage | Use | input |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
P100 WPHNP120A |
Available upon quote |
No voltage contact signal x 1 Interlock, low -speed flow meter, high -speed flow meter (voluntary selection) |
PT100, PT1,000, 10K thermista, 100K thermistor (voluntary selection) automatic temperature compensation | - |
Maximum frequency: 10Hz (duty 50:50) Accident range: 0 to 1,000,000,000 Meter coefficient: 1 to 100,000 lit, gal, m³/1 pulse Unit: Lit, Gal, M³ |
- |
Measurement range: 0.00 to 14.00ph (display range is -2.00 ~ 16.00ph) Resolution: 0.01PH Reproduction: ± 0.05PH (controller alone) |
Maximum frequency: 500Hz (duty 50:50) Accident range: 0 to 1,000,000,000 Pulse constant: 0.01 ~ 100,000.00 pulse/ lit, gal, m³ Unit: Lit, Gal, M³ |
Measurement range: ± 1,500.0mv Resolution: 0.1mv Reproduction: ± 5mv (controller alone) |
Measurement range: 0.0 to 120.0 ° C (display range is -5.0 to 260.0 ° C) Resolution: 0.1 ℃ Straight line: F.S ± 1% (controller alone) |
・ DC4 ~ 20mA output (arbitrary setting possible) Road resistance 600Ω or less for measured values ・ Accuracy: F.S ± 1% |
・ No voltage relay output x 2, voltage contact 1A 250VAC 8a (resistance load) ・ Semiconductor relay output x 2, non -voltage contact 1A 48VAC/DC 0.5A, pump pulse control |
100 ~ 240 VAC, 50/60Hz | No amplifier PH sensor and ORP sensor application |
PH input: Glass film electrode (no amplifier) ORP input: ORP electrode (no amplifier) |
|
W100 WJPHNW120HA-N |
Available upon quote |
No voltage contact signal x 2 Interlock, low -speed flow meter, high -speed flow meter (voluntary selection) |
PT100, PT1,000, 10K thermista, 100K thermistor (voluntary selection) automatic temperature compensation | - |
Maximum frequency: 10Hz (duty 50:50) Accident range: 0 to 1,000,000,000 Meter coefficient: 1 to 100,000 lit, gal, m³/1 pulse Unit: Lit, Gal, M³ |
- |
Measurement range: 0.00 to 14.00ph (display range is -2.00 ~ 16.00ph) Resolution: 0.01PH Reproduction: ± 0.05PH (controller alone) |
Maximum frequency: 500Hz (duty 50:50) Accident range: 0 to 1,000,000,000 Pulse constant: 0.01 ~ 100,000.00 pulse/ lit, gal, m³ Unit: Lit, Gal, M³ |
Measurement range: ± 1,500.0mv Resolution: 0.1mv Reproduction: ± 5mv (controller alone) |
Measurement range: 0.0 to 120.0 ° C (display range is -5.0 to 260.0 ° C) Resolution: 0.1 ℃ Straight line: F.S ± 1% (controller alone) |
・ DC4 ~ 20mA output (arbitrary setting possible) Road resistance 600Ω or less for measured values ・ Accuracy: F.S ± 1% |
・ No voltage relay output x 1, voltage contact 1A 250VAC 6A (resistance load) ・ Semiconductor relay output x 2 No voltage contact points 1A 40VAC/DC 0.2A, pump pulse control |
100 ~ 240 VAC, 50/60Hz | No amplifier PH sensor and ORP sensor application |
PH input: Glass film electrode (no amplifier) ORP input: ORP electrode (no amplifier) |
|
P100 WCNP110A/120A |
Available upon quote |
No voltage contact signal x 1 Interlock, low -speed flow meter, high -speed flow meter (voluntary selection) |
PT100, PT1,000, 10K thermista, 100K thermistor (voluntary selection) automatic temperature compensation |
Resolution: 0.1ms/m, 1ms/m Straight line: F.S ± 1% (controller alone) |
Maximum frequency: 10Hz (duty 50:50) Accident range: 0 to 1,000,000,000 Meter coefficient: 1 to 100,000 lit, gal, m³/1 pulse Unit: Lit, Gal, M³ |
Resolution: 0.001ms/m, 0.01ms/m, 0.1ms/m, 1ms/m Straight line: F.S ± 1% (controller alone) |
- |
Maximum frequency: 500Hz (duty 50:50) Accident range: 0 to 1,000,000,000 Pulse constant: 0.01 ~ 100,000.00 pulse/ lit, gal, m³ Unit: Lit, Gal, M³ |
- |
Measurement range: 0.0 to 120.0 ° C (display range is -5.0 to 260.0 ° C) Resolution: 0.1 ℃ Straight line: F.S ± 1% (controller alone) |
・ DC4 ~ 20mA output (arbitrary setting possible) Road resistance 600Ω or less for measured values ・ Accuracy: F.S ± 1% |
- | 100 ~ 240 VAC, 50/60Hz | General electricity application |
2 -electrode -type power input: 2 electrode -type power conducting sensor Cell constant: 0.01, 0.1, 1, 10 Electromagnetic radiation input: Electromagnetic radiation sensor |
|
W100 WJCNW120HA-N |
Available upon quote |
No voltage contact signal x 2 Interlock, low -speed flow meter, high -speed flow meter (voluntary selection) |
PT100, PT1,000, 10K thermista, 100K thermistor (voluntary selection) automatic temperature compensation |
Resolution: 0.1ms/m, 1ms/m Straight line: F.S ± 1% (controller alone) |
Maximum frequency: 10Hz (duty 50:50) Accident range: 0 to 1,000,000,000 Meter coefficient: 1 to 100,000 lit, gal, m³/1 pulse Unit: Lit, Gal, M³ |
Resolution: 0.001ms/m, 0.01ms/m, 0.1ms/m, 1ms/m Straight line: F.S ± 1% (controller alone) |
- |
Maximum frequency: 500Hz (duty 50:50) Accident range: 0 to 1,000,000,000 Pulse constant: 0.01 ~ 100,000.00 pulse/ lit, gal, m³ Unit: Lit, Gal, M³ |
- |
Measurement range: 0.0 to 120.0 ° C (display range is -5.0 to 260.0 ° C) Resolution: 0.1 ℃ Straight line: F.S ± 1% (controller alone) |
・ DC4 ~ 20mA output (arbitrary setting possible) Road resistance 600Ω or less for measured values ・ Accuracy: F.S ± 1% |
・ No voltage relay output x 1, voltage contact 1A 250VAC 6A (resistance load) ・ Semiconductor relay output x 2, voltage contact point 1A 40VAC/DC 0.2A, pump pulse control |
100 ~ 240 VAC, 50/60Hz | General electricity application |
2 -electrode -type power input: 2 electrode -type power conducting sensor Cell constant: 0.01, 0.1, 1, 10 Electromagnetic radiation input: Electromagnetic radiation sensor |