Price (excluding tax)
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Input digital input
Input temperature input
Measured low -speed flow volume meter -in -flow rate
Measurement PH
Measurement high -speed flow meter integrated flow rate
Measurement orp
Measuring temperature
Output analog output
Output relay output
Power-supply voltage
Use
input
Measured electromagnetic power conducting
Measurement 2 electrode -type power conducting
Part Number
W100 WJCNW120HA-NHandling Company
IWAKI CO., LTD.Items marked with have different values depending on the model number.
Product Image | Price (excluding tax) | Input digital input | Input temperature input | Measured electromagnetic power conducting | Measured low -speed flow volume meter -in -flow rate | Measurement 2 electrode -type power conducting | Measurement high -speed flow meter integrated flow rate | Measuring temperature | Output analog output | Output relay output | Power-supply voltage | Use | input |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Available upon quote | No voltage contact signal x 2 Interlock, low -speed flow meter, high -speed flow meter (voluntary selection) | PT100, PT1,000, 10K thermista, 100K thermistor (voluntary selection) automatic temperature compensation | Resolution: 0.1ms/m, 1ms/m Straight line: F.S ± 1% (controller alone) | Maximum frequency: 10Hz (duty 50:50) Accident range: 0 to 1,000,000,000 Meter coefficient: 1 to 100,000 lit, gal, m³/1 pulse Unit: Lit, Gal, M³ | Resolution: 0.001ms/m, 0.01ms/m, 0.1ms/m, 1ms/m Straight line: F.S ± 1% (controller alone) | Maximum frequency: 500Hz (duty 50:50) Accident range: 0 to 1,000,000,000 Pulse constant: 0.01 ~ 100,000.00 pulse/ lit, gal, m³ Unit: Lit, Gal, M³ | Measurement range: 0.0 to 120.0 ° C (display range is -5.0 to 260.0 ° C) Resolution: 0.1 ℃ Straight line: F.S ± 1% (controller alone) | ・ DC4 ~ 20mA output (arbitrary setting possible) Road resistance 600Ω or less for measured values ・ Accuracy: F.S ± 1% | ・ No voltage relay output x 1, voltage contact 1A 250VAC 6A (resistance load) ・ Semiconductor relay output x 2, voltage contact point 1A 40VAC/DC 0.2A, pump pulse control | 100 ~ 240 VAC, 50/60Hz | General electricity application | 2 -electrode -type power input: 2 electrode -type power conducting sensor Cell constant: 0.01, 0.1, 1, 10 Electromagnetic radiation input: Electromagnetic radiation sensor |