Product
Flow rate that can measure the flow of liquids Proline Prosonic Flow P 500 Ultrasonic flow meterHandling Company
Endress+Hauser Group Services AGCategories
Product Image | Part Number | Price (excluding tax) | Call caliber range | Certification and authentication regarding measurement | Digital communication | Display / operation | Explosion -proof certification | Functional safety | Liquid part material | Material of converter housing | Materials of sensor housing | Maximum measurement error | Maximum process pressure | Measured value | Measurement principle | Measurement range | Peripheral temperature range | Process temperature of measurements | Product safety | Protection grade | input | output | power supply |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Proline Prosonic Flow P 500 |
Available upon quote | Dual channel, 1 or 2 measurement measurement: 15 ~ 4000 mm (1/2-160 ") |
0.3 Except for MHz, total frequency flow meter verification, standard caliber size: 5 MHz 50A, Other total frequency 100A Verification at certified schools (compliant with ISO/IEC 17025) HeartBeat Technolog supports ISO 9001: 2015 - Section 7.1.5.2 A. Measured traceability requirements |
HART, MODBUS RS485 |
4 lines display, display part with backlight, touch control (operated from outside) Options: WLAN Can be set from site display and operation tools |
ATEX, FM/CSA, EAC, UK EX | Functional safety conforming to IEC 61508, adaptation to safety -related applications compliant with IEC 61511 |
Clamp -on system: Sensor Holder 1.4301/SUS 304 equivalent, 1.4404/SUS 316L equivalent Sensor housing 1.4301/SUS 304 equivalent, 1.4404/SUS 316L equivalent Strap band 1.4301/SUS 304 equivalent, 1.4404/SUS 316L equivalent |
ALSI10mg, coating; 1.4409 (CF3M) SUS 316L equivalent | Applicable |
Volume flow rate: ± 3% O.R. (15A) ± 2% O.R. (25 ~ 200 mm) ± 2% O.R. (> 200mm) |
Applicable | Volume flow rate, sound speed, flow speed, accumulation meter | Ultrasonic type | 0 ~ 15 m/s (0 ~ 50 ft/s) |
–40 ~+60 ° C (--40 ~+140 ° f) --50 ~+60 ° C (--58 ~+140 ° F) Options |
Call caliber 15 ~ 65 mm (½ ~ 2½ "): --40 ~+150 ° C (–40 ~+302 ° f) Call Vehicle 50 ~ 4000 mm (2 ~ 160 "): --40 ~+170 ° C (–40 ~+338 ° f) |
CE, C-Tick |
Separate type sensor: IP68, Type 6P container Separate type converter: IP66/67, Type 4X container |
Status input 4 ~ 20 ma input |
3 Output: 4-20 MA Hot (Active/Passive) 4-20 MA Wirelesshart 4-20 MA (Active/Passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output 1 |
DC 24 V AC 100-230 V AC 100-230 V / DC 24 V (non -dangerous place) |
Endress+Hauser Group Services AG