Product
Flowload measurement of liquid, gas, and steam flow meter Proline PROWIRL R 200 Vortex flow meterHandling Company
Endress+Hauser Group Services AGCategories
Product Image | Part Number | Price (excluding tax) | Call caliber range | Certification and authentication regarding measurement | Digital communication | Display / operation | Explosion -proof certification | Ferry class certification and authentication | Functional safety | Liquid part material | Material certificate | Material of converter housing | Materials of sensor housing | Maximum measurement error | Maximum process pressure | Measured value | Measurement principle | Measurement range | Peripheral temperature range | Pressure certification and authentication | Process temperature of measurements | Product safety | Protection grade | input | output | power supply |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Proline PROWIRL R 200 |
Available upon quote | 25 ~ 250 mm (1-10 ") |
Calibration at certification facilities (compliant with ISO/IEC 17025) HeartBeat Technology corresponds to measurement traceability requests conformed to ISO 9001: 2015 - Section 7.1.5.2 a (Tüv Süd certificate) |
HART, Profibus PA, Foundation Field Bus |
4 lines display, display part with backlight, touch control (operated from outside) Can be set from site display and operation tools Separate display can be used |
ATEX, IECEX, CCSAUS, JPN, EAC, UK EX | ABS, LR, BV, DNV GL | Compatible with functional safety that complies with IEC 61508, functional safety applications compliant with IEC 61511 |
Measurement tube: 1.4408 (CF3M) DSC sensor R: 1.4404/SUSF316 or SUSF316L Process connection: 1.4404/SUSF316 or SUSF316L equivalent |
3.1 Material certificate NACE MR0175/MR0103, PMI (inquiry required); ISO 15614-1, equivalent to ASME IX (requested) |
ALSI10mg, coating; 1.4404 (equivalent to SUS316L) | Sensor connection housing: ALSI10mg, coating; 1.4408 (CF3M) |
Volume flow rate (liquid): ± 0.75 % Volume flow rate (steam, gas): ± 1.00 % Mass flow rate (saturated steam): ± 1.7% (temperature correction); ± 1.5% (temperature/pressure correction) Mass flow rate (superheated steam, gas): ± 1.5 (temperature/pressure correction); ± 1.7% (temperature correction + external pressure correction) Mass flow rate (liquid): ± 0.85% |
PN 40, Class 300, 20k | Volume flow, mass flow rate, reference volume flow, energy flow, heat flow difference, temperature | Whirlpool |
Liquid: 0.1 ~ 540 m³/h (0.061 ~ 320 ft³/min) According to the measurement: 0.1MPa, 20 ° C water (14.5 PSI A, 68 ° f) Steam, gas: 0.52 ~ 7300 m³/h (0.31 ~ 4300 ft³/min) According to the measured object: 1MPa, 180 ° C steam (356 ° F, 145 PSI A); 0.44MPa, 25 ° C air (77 ° F, 63.8 PSI A) |
Integrated type (standard): --40 ~+80 ° C (--40 ~+176 ° F) Integrated type (option): --50 ~+80 ° C (--58 ~+176 ° f) Separate type (standard): --40 ~+85 ° C (–40 ~+185 ° F) Separate type (option): --50 ~+85 ° C (–58 ~+185 ° f) |
PED, CRN, AD 2000 |
Standard: --40 ~+260 ° C (–40 ~+500 ° f) High temperature/low temperature (option): --200 ~+400 ° C (–328 ~+752 ° f) High temperature/low temperature (inquiry required): --200 ~+450 ° C (–328 ~+842 ° f) |
CE, C-Tick, EAC |
Integrated type: IP66/67, Type 4X container Separate type sensor: IP66/67, Type 4X container Separate type converter: IP66/67, Type 4X container |
4 ~ 20 ma (passive) |
4-20 MA HART (passive) 4-20 MA (passive) Pulse/frequency/switch output (passive) |
DC 12 ~ 35 V (4-20 MA Hot available/no pulse/frequency/switch output) DC 12 ~ 30 V (4-20 Ma heat, 4-20 ma) DC 12 ~ 35 V (4-20 MA heat, pulse/frequency/switch output, 4-20 ma input) DC 9 ~ 32 V (Profibus PA, pulse/frequency/switch output) |
Endress+Hauser Group Services AG