Flowload measurement of liquid, gas, and steam flow meter Proline PROWIRL R 200 Vortex flow meter-Proline PROWIRL R 200
Flowload measurement of liquid, gas, and steam flow meter Proline PROWIRL R 200 Vortex flow meter-Endress+Hauser Group Services AG

Flowload measurement of liquid, gas, and steam flow meter Proline PROWIRL R 200 Vortex flow meter
Endress+Hauser Group Services AG


About This Product

Flow meter that provides the highest class accuracy despite the pipe size redus ■ Applications PROWIRL R is designed for low flow and is a reliable solution for energy management. In addition, PremiumCal, a calibration option, offers a very good measurement accuracy for the highest factory operating rate. The PROWIRL R 200 is equipped with a loop power technology and can be integrated low and seamlessly into existing facilities. Provides the highest level of operation safety in dangerous places and always guarantees process safety by HeartBeat Technology. ・ Optimal measurement principle for wet/saturation/superheated steam, gas and liquid (including ultra -low temperature) ・ For applications with low flow rate. ■ Features of equipment ・ 1 or 2 size redus ・ Up to 250 mm (10 ") ・ The position of the pressure sensor is flexible ・ Display module with data transfer function ・ Highly robust dual compartment housing ・ Plant safety: global authentication (SIL, dangerous place) ■ Advantages ・ Easy to manage energy - Temperature/pressure gauge built -in for steam and gas ・ Saving costs and time -No piping changes are required for size redus ・ The same accuracy up to RE 10,000 - the most linear vortex total ・ Long -term stability - highly robust, no drift -free capacitance sensor ・ Easy equipment wiring -Independent terminal box ・ Safety of operation - Touch control operation No need to open the device for the display with backlight ・ Built -in verification function - HeartBeat Technology ■ Product ・ A flow meter that provides the highest class accuracy despite the pipe size redus. ・ Easy to manage energy -built -in temperature/pressure gauge for steam and gas. ・ For applications with low flow rate. ■ Features of sensor ・ Saving costs and time -No piping changes are required for size redus. ・ The same accuracy up to Re 10,000 -the most linear whirlpool volume. ・ Long -term stability -static capacity sensor with high robustness, drift. ・ 1 or 2 size redus of the diameter. ・ Call diameter (piping piping) up to 250 mm (10 ""). ■ Features of converter ・ Saving costs and time -No piping changes are required for size redus. ・ The same accuracy up to Re 10,000 -the most linear whirlpool volume. ・ Long -term stability -static capacity sensor with high robustness, drift. ・ 1 or 2 size redus of the diameter. ・ Call diameter (piping piping) up to 250A (10 ""). ・ The position of the pressure sensor is flexible.

  • Product

    Flowload measurement of liquid, gas, and steam flow meter Proline PROWIRL R 200 Vortex flow meter




*Please note that we may not be able to accommodate sample requests.

1 Models of Flowload measurement of liquid, gas, and steam flow meter Proline PROWIRL R 200 Vortex flow meter

Product Image Part Number Price (excluding tax) Call caliber range Certification and authentication regarding measurement Digital communication Display / operation Explosion -proof certification Ferry class certification and authentication Functional safety Liquid part material Material certificate Material of converter housing Materials of sensor housing Maximum measurement error Maximum process pressure Measured value Measurement principle Measurement range Peripheral temperature range Pressure certification and authentication Process temperature of measurements Product safety Protection grade input output power supply
Flowload measurement of liquid, gas, and steam flow meter Proline PROWIRL R 200 Vortex flow meter-Part Number-Proline PROWIRL R 200

Proline PROWIRL R 200

Available upon quote 25 ~ 250 mm (1-10 ") Calibration at certification facilities (compliant with ISO/IEC 17025)
HeartBeat Technology corresponds to measurement traceability requests conformed to ISO 9001: 2015 - Section 7.1.5.2 a (Tüv Süd certificate)
HART, Profibus PA, Foundation Field Bus 4 lines display, display part with backlight, touch control (operated from outside)
Can be set from site display and operation tools
Separate display can be used
ATEX, IECEX, CCSAUS, JPN, EAC, UK EX ABS, LR, BV, DNV GL Compatible with functional safety that complies with IEC 61508, functional safety applications compliant with IEC 61511 Measurement tube: 1.4408 (CF3M)
DSC sensor R: 1.4404/SUSF316 or SUSF316L
Process connection: 1.4404/SUSF316 or SUSF316L equivalent
3.1 Material certificate
NACE MR0175/MR0103, PMI (inquiry required); ISO 15614-1, equivalent to ASME IX (requested)
ALSI10mg, coating; 1.4404 (equivalent to SUS316L) Sensor connection housing: ALSI10mg, coating; 1.4408 (CF3M) Volume flow rate (liquid): ± 0.75 %
Volume flow rate (steam, gas): ± 1.00 %
Mass flow rate (saturated steam): ± 1.7% (temperature correction); ± 1.5% (temperature/pressure correction)
Mass flow rate (superheated steam, gas): ± 1.5 (temperature/pressure correction); ± 1.7% (temperature correction + external pressure correction)
Mass flow rate (liquid): ± 0.85%
PN 40, Class 300, 20k Volume flow, mass flow rate, reference volume flow, energy flow, heat flow difference, temperature Whirlpool Liquid: 0.1 ~ 540 m³/h (0.061 ~ 320 ft³/min)
According to the measurement: 0.1MPa, 20 ° C water (14.5 PSI A, 68 ° f)
Steam, gas: 0.52 ~ 7300 m³/h (0.31 ~ 4300 ft³/min)
According to the measured object: 1MPa, 180 ° C steam (356 ° F, 145 PSI A); 0.44MPa, 25 ° C air (77 ° F, 63.8 PSI A)
Integrated type (standard): --40 ~+80 ° C (--40 ~+176 ° F)
Integrated type (option): --50 ~+80 ° C (--58 ~+176 ° f)
Separate type (standard): --40 ~+85 ° C (–40 ~+185 ° F)
Separate type (option): --50 ~+85 ° C (–58 ~+185 ° f)
PED, CRN, AD 2000 Standard: --40 ~+260 ° C (–40 ~+500 ° f)
High temperature/low temperature (option): --200 ~+400 ° C (–328 ~+752 ° f)
High temperature/low temperature (inquiry required): --200 ~+450 ° C (–328 ~+842 ° f)
CE, C-Tick, EAC Integrated type: IP66/67, Type 4X container
Separate type sensor: IP66/67, Type 4X container
Separate type converter: IP66/67, Type 4X container
4 ~ 20 ma (passive) 4-20 MA HART (passive)
4-20 MA (passive)
Pulse/frequency/switch output (passive)
DC 12 ~ 35 V (4-20 MA Hot available/no pulse/frequency/switch output)
DC 12 ~ 30 V (4-20 Ma heat, 4-20 ma)
DC 12 ~ 35 V (4-20 MA heat, pulse/frequency/switch output, 4-20 ma input)
DC 9 ~ 32 V (Profibus PA, pulse/frequency/switch output)

Customers who viewed this product also viewed

Other products of Endress+Hauser Group Services AG


View more products of Endress+Hauser Group Services AG

About Company Handling This Product

Endress+Hauser Group Services AG

  • United States of America

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.