Water quality analysis meter Digital non -glass PH sensor MEMOSENS CPS47E corresponding to water quality analysis parameters-Memosens CPS47E
Water quality analysis meter Digital non -glass PH sensor MEMOSENS CPS47E corresponding to water quality analysis parameters-Endress+Hauser Group Services AG

Water quality analysis meter Digital non -glass PH sensor MEMOSENS CPS47E corresponding to water quality analysis parameters
Endress+Hauser Group Services AG


About This Product

Chemistry, Life Science, Memosens 2.0 ISFET PH Electreme for Food Industry ◾️ Application Memosens CPS47E is a high -performance KCL -supplied digital sensor suitable for measurements with low conductivity and highly organic loads. It also realizes accurate measurements in applications that are easy to change. It ensures the safety of the product by the shaft that is hard to damage. Memosens 2.0 Digital technology provides a moisturizing PH sensor, improving the safety of the process, improving the safety of the process, and simplifying the operation. Calibration and process data can be saved in more information, so that a foundation for predictive conservation is built. It is suitable for measurements containing high -concentration organic solvents and extremely low measurement applications. ・ Measurement of chemical industry, easy to clog ・ Power plant, example: Boiler can water ・ Life Science Industry, Example: Injecting water Obtain all authentication related to sanitar application (EHEDG, 3A, EU1935/2004, USP 87/88, etc.) ◾️Anucial ・ Compatible with industrial IoT Memosens 2.0 records proofreading and process data in more information, enables excellent trend identification, and provides the basics of advanced IIOT services that have been predictive and enhanced. ・ It is hard to damage The highest -level product safety in a PEEK non -glass housing in a place where glass damage is not allowed ・ Toxic resistance Stable KCL replenishment to the electrode and independent reference lead prevention of pollution due to an ionic contamination into the electrode ・ The sensor is compatible with the sterilization of autoclave and high -temperature steam. We provide stable measurement in the long term. ・ Minimum maintenance The ISFET technology, which is less likely to be affected by temperature changes, achieves a long calibration cycle. ・ Maximum process safety Non -contact -type electromagnetic induction signal transmission has eliminated the problem associated with moisture. ・ Reduction of operating costs The lab calibration and the short -term sensor replacement at the site minimizes the downtime of the process and extends the life of the sensor.

  • Product

    Water quality analysis meter Digital non -glass PH sensor MEMOSENS CPS47E corresponding to water quality analysis parameters

Share this product


200+ people viewing


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

1 Models of Water quality analysis meter Digital non -glass PH sensor MEMOSENS CPS47E corresponding to water quality analysis parameters

Product Image Part Number Price (excluding tax) Characteristic Explosion -proof standard conformity certificate External dimensions Material Measurement principle Measurement range Process pressure Process temperature Protection grade Temperature sensor application connection reference structure
Water quality analysis meter Digital non -glass PH sensor MEMOSENS CPS47E corresponding to water quality analysis parameters-Part Number-Memosens CPS47E

Memosens CPS47E

Available upon quote Digital PH electrode for manufacturing processes for sterilization and autoclave, equipped with a KCL container suitable for measurement of measurements with low conductivity Dangerous place Authentication for use with Zone 0, Zone 1, and Zone 2: ATEX, IECEX, CSA C/US, NEPSI, JPN EX, Inmetro, UKCA, KOREA EX Diameter: 12 mm (0.47 INCH)
Shaft length: 120, 225, 360 mm
(4.72, 8.86, 14.17 INCH)
Senshaft: PEEK
Seal: FFKM
Metal lead: AG/AGCL
Liquid film: Ceramic liquid film, dialconium dinoxure
O -ring: FKM
Process coupling: PPS glass fiber strengthening
Nameplate: Metal Oxide Ceramic
ISFET PH 0 ~ 14 Maximum absolute pressure: 1.1 mpa 100 ° C
(Up to 160 PSI 212 ° F)
-15 ~ 135 ° C (5-275 ° f) IP 68 PT1000 For applications that require high accuracy in an environment that contains a large amount of adhesions and organic solvents Non -contact connection head of electromagnetic induction transmission equipped with Memosens 2.0 technology KCL electrolytic solution structure

Customers who viewed this product also viewed

Other products of Endress+Hauser Group Services AG


View more products of Endress+Hauser Group Services AG

About Company Handling This Product

Endress+Hauser Group Services AG

  • United States of America

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree