Product
3D radar safety system Robo SafeHandling Company
Komori Safety Device Lab Co.,LtdCategories
Product Image | Part Number | Price (excluding tax) | Assembly (controller) | CAN bus terminal resistance (sensor) | Communication protocol (sensor controller) | Connector (CAN bus cable) | Connector (sensor) | Cross -sectional area (CAN bus cable) | Detection area and installation height | Detection interval | Enter (controller) | Impedance (CAN bus cable) | Length (CAN bus cable) | Material (sensor) | Method of detection | Operating temperature | Output (controller) | Power (controller) | Power (sensor) | Power consumption (controller) | Protection grade (controller) | Protection grade (sensor) | Response time | SIL (safety level) | Safe output (controller) | Setting option (controller) | Shield (CAN bus cable) | Storage temperature | Terminal (controller) | Type (CAN bus cable) | Warranty period | frequency |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Robo Is |
Available upon quote | Din guide | 120Ω (not unusual, please attach it with the terminal connector) | CAN complies with standard EN50325-5 | 5-pole M12 | 25-PIN M12 connector (male 1, female 1) | Signal 2 × 0.25㎟ Power supply 2 × 0.34㎟ data |
Wide detection range: 110 ° horizontal 30 ° vertical, height: 0 to 3 m (0 to 9.8ft) Narrow detection range: 50 ° horizontal 15 ° vertical, height: 0 to 3 m (0 ~ 9.8 FT) |
1 ~ 4 (3.2 ~ 13.1 ft). Depending on the installation conditions | 2 Dual channel type Digital input with 3GND | 120Ω ± 12Ω (f = 1 mHz) | 30m (98.4ft) from the controller to the sensor (1 sensor configuration) | Sensor Case: PA66 Bracket: PA66 and Glass Fiber (GF) | INXPECT motion detection algorithm based on FMCW radar | -30 ~+60 ° C (-22 ~+140 ° f) |
4 Output signal switching device (OSSD) Two dual channel safety output |
24VDC (20-28VDC) Maximum current: 0.6A | 12V DC ± 20 %, via controller | Up to 5W output | IP20 | IP67 | <100ms | SIL2 (Category-3/LBK-S01 Category-2) |
High -side output (with expansion protection function) Maximum voltage: 30VDC Human current: 0.4A Maximum power: 12W |
USB: ISC-B01, ISC-02, ISC-03 Ethernet: ISC-B01.isc-02 Field Bus: ISC-B01 |
Silver -plated Shield with twist wires in copper wire. Earth connection is required | -40 ~+80 ° C (-40 ~+176 ° f) | Cross section: 1mm2 (AWG16) maximum current: 4A | Two twist pairs: Power, signal (shield) | 36 months from the date of purchase of the product (limited to sensors and controllers) |
Operating band: 24-24, 25GHz (24.05 to 24.25 in the UK and France) Sending power: ≦ 13dbm- Modification: FMCW10 |