Price (excluding tax)
■ Model: PBA 5001 Soft Drink ・ Simultaneous measurement of standard ° brix and CO2 content ・ Measurements are 6 times higher than the conventional method ・ Module type setup: 10 or more industry parameters can be measured ・ The impact of the dissolved CO2 on the results of ° brix is zero. ・ Completed package analysis: Not affected by operators.
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Ambient temperature
Communication interface
Convenient function
Dimensions (depth x width x height)
Environmental condition
Humidity
Internal storage capacity
Measurement range CO2 concentration
Measurement range O₂ concentration
Measurement range density
Measurement range measured sugar content
Measurement range pH value
Measurement range pressure
Measurement range temperature
Measurement time per sample
Minimum sample amount for each measurement
Repeated accuracy standard deviation CO2 concentration
Repeated accuracy standard deviation O₂ concentration
Repeated accuracy standard deviation density
Repeated accuracy standard deviation measured sugar content
Sample loopput
Standard deviation PH value of repeated accuracy
Standard deviation temperature of repeated accuracy
System operation
display
power supply
weight
Measurement range diet concentration
Repeated accuracy standard deviation diet concentration
Part Number
PBA 5001 Soft DrinkProduct
Conducted quality control test of soft drinks at once package beverage analyzer PBA 5001 Soft DrinkHandling Company
Anton Paar GmbHItems marked with have different values depending on the model number.
Product Image | Price (excluding tax) | Ambient temperature | Communication interface | Convenient function | Dimensions (depth x width x height) | Environmental condition | Humidity | Internal storage capacity | Measurement range CO2 concentration | Measurement range O₂ concentration | Measurement range density | Measurement range measured sugar content | Measurement range pH value | Measurement range pressure | Measurement range temperature | Measurement time per sample | Minimum sample amount for each measurement | Repeated accuracy standard deviation CO2 concentration | Repeated accuracy standard deviation O₂ concentration | Repeated accuracy standard deviation density | Repeated accuracy standard deviation measured sugar content | Sample loopput | Standard deviation PH value of repeated accuracy | Standard deviation temperature of repeated accuracy | System operation | display | power supply | weight |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Available upon quote | 15 ~ 35 ℃ | USB x 5, Ethernet, CAN, RS232 | U-VIEW ™, FillingCheck ™, ThermoBalance ™, full-range viscosity correction, Ultrafast measurement mode status monitoring | 526 x 730 x 446mm | (EN 61,010) Indoor only | No condensation 20 ℃: Relative humidity less than 90% 25 ℃: Relative humidity less than 60% 30 ℃: Relative humidity less than 45% | Measurement values with up to 10,000 camera images | In the case of 30 ° C, 0 ~ 6vol. (0 ~ 12g/l) If it is less than 15 ° C, 0-10Vol. (0 ~ 20g/l) | 0 ~ 4ppm | 0 ~ 3g/cm³ | 0 ~ 15 ° BRIX | PH 0 ~ 14 | Up to 10 Bar (absolute pressure) | 20 | 3 minutes (%DIET analysis 6 minutes) | 150 | 0.005vol. (0.01 g/l) | 2PPB (range less than 200 ppb) | 0.00001g/cm³ (DMA 4101) 0.000005g/cm³ (DMA 4501) 0.000001g/cm³ (DMA 5001) | 0.015 ° BRIX (DMA 4101) 0.01 ° BRIX (DMA 4501) <0.01 ° BRIX (DMA 5001) | 10 to 20 samples per hour (depending on the system configuration) | 0.02 (range of pH 3 to 7) | 0.02 ° C (DMA 4101) 0.01 ℃ (DMA 4501) 0.001 ℃ (DMA 5001) | Touch screen, options (keyboard, mouse, barcode reader) | 10.1 inch, TFT WXGA (1,280 x 800px), PCAP touch screen | AC 100-240V, 50/60Hz, fluctuation ± 10%, 190VA | Approximately 35.7kg |