Price (excluding tax)
■ Model: SVM 1001 Simple Fill ・ Automatic viscosometer of compact design (with battery options) ・ Realizes 150%improvement in throughput compared to conventional manual glass capture capillary viscosometer ・ Inject the sample directly into the funnel without using pipettes or syringe ・ Because it is possible to clean and dry, reduce the effort of operators ・ Any temperature can be selected between 15 and 100 ° C
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Built -in memory
Dimensions (width x depth x height)
HID (Human interface device)
Maximum sample loopput
Measurement range temperature
Measurement range viscosity
Minimum amount of solvent / normal amount
Net weight (kg)
Optional upgrade
Patent
Peripheral conditions
Repeated accuracy and reproducibility of the viscosity * 1
Repeated accuracy of accuracy temperature
Reproduction of accuracy temperature
Sample minimum amount / normal amount
Test method
accessories
interface
power supply
automation
Measurement range density
Repeated accuracy and reproducibility of accuracy * 1
Accurate cloudy point/repetition of accuracy and reproducibility * 1
Part Number
105011Handling Company
Anton Paar GmbHItems marked with have different values depending on the model number.
Product Image | Price (excluding tax) | Built -in memory | Dimensions (width x depth x height) | HID (Human interface device) | Maximum sample loopput | Measurement range temperature | Measurement range viscosity | Minimum amount of solvent / normal amount | Net weight (kg) | Optional upgrade | Patent | Peripheral conditions | Repeated accuracy and reproducibility of the viscosity * 1 | Repeated accuracy of accuracy temperature | Reproduction of accuracy temperature | Sample minimum amount / normal amount | Test method | accessories | automation | interface | power supply |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Available upon quote | 1,000 measurement results can be saved | SVM (13,411,996), FillingCheck (6,834,725), ABBEMAT (1,084,545) | 7 inch touch screen | 21 Sample/H | +15 ~+100 ° C (1 point temperature, 2nd point temperature) | 0.3 ~ 5,000mm²/s | 5ml / 10ml | 33 x 36.5 x 20.5cm | The second point temperature | AT516,058 (B1), US10,036,695 (B2), CN105 ,424,556, EP29,959,28 (B1) | 6.6 | 0.1%, 0.35% | 0.005 | +15 ~+100 ℃: 0.03 ℃ | 3.5ml / 8ml | ASTM D7,042, D445 bias correction, ISO 23,581, en 16,896 | 7 inch touch screen | Integrated Simple Fill filling device | USB × 4 (A × 3, B × 1) | 15 ~ 35 ° C, relative humidity of 80%or less, no condensation |