Price (excluding tax)
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Ambient temperature
Analog output
CE Label
Communication function
Configuration input/output
Detector
Emissivity
Exposure time
Fill Factor Spot Size
Gray ratio
Housing
Optical system
Peak picker
Permeability
Relative temperature
Reproducibility
Response time T90
Spectrum range
Supply power supply
Temperature range
Temperature sublerange
Uncertainty
Visual Organization (selection)
Weight
display
isolation
parameter settings
Part Number
H322Handling Company
Japan SensorItems marked with have different values depending on the model number.
Product Image | Price (excluding tax) | Ambient temperature | Analog output | CE Label | Communication function | Configuration input/output | Detector | Emissivity | Exposure time | Fill Factor Spot Size | Gray ratio | Housing | Optical system | Peak picker | Permeability | Relative temperature | Reproducibility | Response time T90 | Spectrum range | Supply power supply | Temperature range | Temperature sublerange | Uncertainty | Visual Organization (selection) | Weight | display | isolation | parameter settings |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Available upon quote | 0 to 80 ° C, optical side of optical fiber devices: -20 to 250 ° C, Storage: -20 to 85 ° C | Two diverse analog output 0 or 4 ~ 20ma maximum load: 500Ω, 0.0015%resolution of adjusted temperature (16 bits). | According to the EU command of electromagnetic immunity | RS485 (max.921 KBD) Resolution ability 0.1 ℃ or 0.1 ° f | 12-Pin Connector Model: 3 ports, setable digital input or output, 17-Pin Connector Model: 4 Digital input, 2 digital output, 1 analog output | 2 × INGAAS | 0.050-1.200 (compatible with 5-120%in 0.1%step for each channel) | <40 μs | 0.050-1.000 (compatible with 5-100%for each channel, 0.1%step) | 0.800-1.200 | Aluminum/Protection class IP65 with connector DIN40050 compliant | Manual movable focus optical system (as an integration or optical fiber version) | Automatic hold mode or manual time setting clear (reset) | 0.050-1.000 (compatible with 5-100%for each channel, 0.1%step) | No condensed conditions | Measured value ℃ 0.2% + 1K | <80 μs, Adjustable Up to 10s | Channel 1: 1.65-1.8 μm / Channel 2: 1.45-1.65 μm, Channel 1: 1.64 μm / Channel 2: 1.4 μm | 24V DC (18-30V DC), Max.6 Va; Protection from reverse polarity | 350-800 ° C 400-1,200 ° C 500-1,300 ° C 550-1,400 ° C 700-2,300 ° C 1,000-2,500 ° C 1,300-3,000 ° C | At the temperature of 50 ° C or higher, any range can be adjusted in the temperature range at 50 ° C or higher. | Measured value ℃ 0.5% + 1K | ・ Variable light -reduced light flutter equipment for protection of direct visual mechanism ・ Laser visual mechanism ・ High dynamic color CCD camera | 650g | Only 12-Pin Connector model: Displays temperature display and parameter settings on 10-digit LED display (5mm high). Temperature resolution is 0.1 ℃ | Power supply, analog output, and serial interfaces are electrically insulated with each other. | 12-Pin Connector Model: Use the dedicated software Sensor Tools with the press button on the main unit or in serial communication. 17-Pin Connector Model: Only dedicated software Sensor Tools is used for serial communication. |