Product
Label printer scentronics CL4NX-J plus seriesHandling Company
Ma Stoken SolutionItems marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | 2D code | Body memory | Continuous paper length | Dimension/weight | For standard interface settings | Head density | Incribon (other specifications) | Ink ribbon width | Installation function | Label (other specifications) | Label (roll) | Other standards | Paper length Hakuri | Paper length cutter | Paper length non -specs | Paper length tier off | Paper width (common) | Power supply standard | Preserved environment | Printing effective area | Printing speed | Printing system | Receiving buffer | Standard -equipped font | Standard interface communication | Synthetic symbol | Use environmental conditions | barcode | power consumption | specification |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CL4NX-J 08 Plus |
Available upon quote | QR code (including micro QR), security QR, PDF417 (including micro PDF), Maxi code, GS1 data matrix, data matrix (ECC200), Aztec code | Up to 679MB | 6 to 2497mm | Width 271mm x depth 457mm x height 321mm (including projections) Approximately 15.1kg (including paper, ribbon or options) | USB2.0HIGHSPEEDTYPEA * 2 ports | 8dot/mm (203dpi) | Winding direction: front/back roll combined use, paper les, up to 600m | 39.5, 45, 59, 76, 84, 92, 102, 111, 128mm | Guidance video display function, LCD30 language display, cleaning notification function, head check function, calendar (optional), SNMPV3, password lock, logo font download function, LCD extinguishing function, standby function, status reply function etc. | Winding direction: front/back winding combined, paper thickness: 80-268 μm, paper tube inner diameter of 76mm/101mm, fanfall drabel (fold label) | Maximum outer diameter φ265mm (φ10 inch) | Environmental Standards: International Energy Star Program Ver2.0, ROHS regulations, noise standards: VCCIB | 10-397mm (10-27mm only for heat transfer operation) | 17-2497mm | Length 30-120mm width 60-118mm | 17-2497mm | 22-128mm (mount including 25-131mm) | Input voltage: AC100V to 240V ± 10 % (full range) frequency: 50/60Hz | -20-60 ° C/30-90 % RH (but no condensation) * Excluding supplements | Width 104mm * Length 2500mm | Up to about 355mm/second (up to 14inch/second) | Combined heat/thermal transfer method | Buffanias full 2.0MB, buffer 2.95MB, 1.0MB | Bitmap Font: alphanumeric characters, symbols, kana: x20 (5 × 9), X21 (17 × 17), X22 (24 × 24), X23 (48 × 48), X24 (48 × 48)/OCR (alphanumeric symbols): OCR-A (15 × 22), OCR-B (20 × 24), Kanji : (16 × 16, 22 × 22, 24 × 24, 32 × 32, 40 × 40 [DOT])/Standard: JISX0208-1993JIS 1st to 2nd Level 2 Gothic Switching, Expansion: JISX0213-2004JIS 1st to 4th Level Gothic/Scalable Fonts: 15SC: 15SC AlableSatofonts, Multi-NATIONALLANGUAGESUSUPPORT (47Languages/Unicode), Singleanddoolebytefonts (Korean, CHINESE, JAPANESE) | LAN10BASE-T/100BASE-TX (IPv4/IPv6, SNMPV1-V3MIB-II, FTP, NTP, LPR, DHCP, HTTP/HTTPS), USB2.0HIGHSPEEDTYPEB, NFC | GS1DATABARCOMPOSITE, GS1DATABARTRUNCATEDCOMPOSITE, GS1DATABARSTACKEDCOMPOSITE, GS1DataBarstackedomnidomnid reporting, GS1DAT, GS1DAT ABARLIMITEDCOMPOSITE, GS1DATABAREXPANDEDCOMPOSITE, GS1DatabarexpandStackedComposite Note: GS1DATABAR is RSS. | Label (other than Hakuri): 0-40 ° C/30-80 % RH, label (Hakuri): 5-35 ° C/30-80 % RH, non -order: 5-35 ° C/30-75 % RH (without condensation, excluding supplies) | UPC-A, UPC-E, Jan/Ean, Code93, Code93, Code128 (UCC/EAN128), Codabar (NW-7), ITF, Industrial 2OF5, NEC Matrix 2OF5, MSI, Customer Cord, Postnet, Postnet UPC add -on code, Bookland, USPS code, GS1DataBaromnidInidirectional, GS1Databartruncated, GS1DataBarstacked, GS1DataBarstackedomnidialECTIONIR, G S1Databarlimited, GS1DATABAREXPANDED, GS1DATABAREXPANDEDSTACKED | Peak time ( * 2): 190va/180W (30 % printing) When standing: 27va/22W | Standard/Cutter/Hakuri/Non -Sepa | |
CL4NX-J 12 Plus |
Available upon quote | QR code (including micro QR), security QR, PDF417 (including micro PDF), Maxi code, GS1 data matrix, data matrix (ECC200), Aztec code | Up to 679MB | 6-1497mm | Width 271mm x depth 457mm x height 321mm (including projections) Approximately 15.1kg (including paper, ribbon or options) | USB2.0HIGHSPEEDTYPEA * 2 ports | 12dot/mm (305dpi) | Winding direction: front/back roll combined use, paper les, up to 600m | 39.5, 45, 59, 76, 84, 92, 102, 111, 128mm | Guidance video display function, LCD30 language display, cleaning notification function, head check function, calendar (optional), SNMPV3, password lock, logo font download function, LCD extinguishing function, standby function, status reply function etc. | Winding direction: front/back winding combined, paper thickness: 80-268 μm, paper tube inner diameter of 76mm/101mm, fanfall drabel (fold label) | Maximum outer diameter φ265mm (φ10 inch) | Environmental Standards: International Energy Star Program Ver2.0, ROHS regulations, noise standards: VCCIB | 10-397mm (10-27mm only for heat transfer operation) | 17-1497mm | Length 30-120mm width 60-118mm | 17-1497mm | 22-128mm (mount including 25-131mm) | Input voltage: AC100V to 240V ± 10 % (full range) frequency: 50/60Hz | -20-60 ° C/30-90 % RH (but no condensation) * Excluding supplements | Width 104mm * Length 1500mm | Up to about 355mm/second (up to 14inch/second) | Combined heat/thermal transfer method | Buffanias full 2.0MB, buffer 2.95MB, 1.0MB | Bitmap Font: alphanumeric characters, symbols, kana: x20 (5 × 9), X21 (17 × 17), X22 (24 × 24), X23 (48 × 48), X24 (48 × 48)/OCR (alphanumeric symbols): OCR-A (15 × 22), OCR-B (20 × 24), Kanji : (16 × 16, 22 × 22, 24 × 24, 32 × 32, 40 × 40 [DOT])/Standard: JISX0208-1993JIS 1st to 2nd Level 2 Gothic Switching, Expansion: JISX0213-2004JIS 1st to 4th Level Gothic/Scalable Fonts: 15SC: 15SC AlableSatofonts, Multi-NATIONALLANGUAGESUSUPPORT (47Languages/Unicode), Singleanddoolebytefonts (Korean, CHINESE, JAPANESE) | LAN10BASE-T/100BASE-TX (IPv4/IPv6, SNMPV1-V3MIB-II, FTP, NTP, LPR, DHCP, HTTP/HTTPS), USB2.0HIGHSPEEDTYPEB, NFC | GS1DATABARCOMPOSITE, GS1DATABARTRUNCATEDCOMPOSITE, GS1DATABARSTACKEDCOMPOSITE, GS1DataBarstackedomnidomnid reporting, GS1DAT, GS1DAT ABARLIMITEDCOMPOSITE, GS1DATABAREXPANDEDCOMPOSITE, GS1DatabarexpandStackedComposite Note: GS1DATABAR is RSS. | Label (other than Hakuri): 0-40 ° C/30-80 % RH, label (Hakuri): 5-35 ° C/30-80 % RH, non -order: 5-35 ° C/30-75 % RH (without condensation, excluding supplies) | UPC-A, UPC-E, Jan/Ean, Code93, Code93, Code128 (UCC/EAN128), Codabar (NW-7), ITF, Industrial 2OF5, NEC Matrix 2OF5, MSI, Customer Cord, Postnet, Postnet UPC add -on code, Bookland, USPS code, GS1DataBaromnidInidirectional, GS1Databartruncated, GS1DataBarstacked, GS1DataBarstackedomnidialECTIONIR, G S1Databarlimited, GS1DATABAREXPANDED, GS1DATABAREXPANDEDSTACKED | Peak time ( * 2): 190va/180W (30 % printing) When standing: 27va/22W | Standard/Cutter/Hakuri/Non -Sepa | |
CL4NX-J 24 Plus |
Available upon quote | QR code (including micro QR), security QR, PDF417 (including micro PDF), Maxi code, GS1 data matrix, data matrix (ECC200), Aztec code | Up to 679MB | 6-397mm | Width 271mm x depth 457mm x height 321mm (including projections) Approximately 15.1kg (including paper, ribbon or options) | USB2.0HIGHSPEEDTYPEA * 2 ports | 24dot/mm (609dpi) | Winding direction: front/back roll combined use, paper les, up to 600m | 39.5, 45, 59, 76, 84, 92, 102, 111, 128mm | Guidance video display function, LCD30 language display, cleaning notification function, head check function, calendar (optional), SNMPV3, password lock, logo font download function, LCD extinguishing function, standby function, status reply function etc. | Winding direction: front/back winding combined, paper thickness: 80-268 μm, paper tube inner diameter of 76mm/101mm, fanfall drabel (fold label) | Maximum outer diameter φ265mm (φ10 inch) | Environmental Standards: International Energy Star Program Ver2.0, ROHS regulations, noise standards: VCCIB | 10-397mm (10-27mm only for heat transfer operation) | 17-397mm | Length 30-120mm width 60-118mm | 17-397mm | 22-128mm (mount including 25-131mm) | Input voltage: AC100V to 240V ± 10 % (full range) frequency: 50/60Hz | -20-60 ° C/30-90 % RH (but no condensation) * Excluding supplements | Width 104mm * Length 400mm | Up to about 152mm/second (up to 6inch/second) | Combined heat/thermal transfer method | Buffanias full 2.0MB, buffer 2.95MB, 1.0MB | Bitmap Font: alphanumeric characters, symbols, kana: x20 (5 × 9), X21 (17 × 17), X22 (24 × 24), X23 (48 × 48), X24 (48 × 48)/OCR (alphanumeric symbols): OCR-A (15 × 22), OCR-B (20 × 24), Kanji : (16 × 16, 22 × 22, 24 × 24, 32 × 32, 40 × 40 [DOT])/Standard: JISX0208-1993JIS 1st to 2nd Level 2 Gothic Switching, Expansion: JISX0213-2004JIS 1st to 4th Level Gothic/Scalable Fonts: 15SC: 15SC AlableSatofonts, Multi-NATIONALLANGUAGESUSUPPORT (47Languages/Unicode), Singleanddoolebytefonts (Korean, CHINESE, JAPANESE) | LAN10BASE-T/100BASE-TX (IPv4/IPv6, SNMPV1-V3MIB-II, FTP, NTP, LPR, DHCP, HTTP/HTTPS), USB2.0HIGHSPEEDTYPEB, NFC | GS1DATABARCOMPOSITE, GS1DATABARTRUNCATEDCOMPOSITE, GS1DATABARSTACKEDCOMPOSITE, GS1DataBarstackedomnidomnid reporting, GS1DAT, GS1DAT ABARLIMITEDCOMPOSITE, GS1DATABAREXPANDEDCOMPOSITE, GS1DatabarexpandStackedComposite Note: GS1DATABAR is RSS. | Label (other than Hakuri): 0-40 ° C/30-80 % RH, label (Hakuri): 5-35 ° C/30-80 % RH, non -order: 5-35 ° C/30-75 % RH (without condensation, excluding supplies) | UPC-A, UPC-E, Jan/Ean, Code93, Code93, Code128 (UCC/EAN128), Codabar (NW-7), ITF, Industrial 2OF5, NEC Matrix 2OF5, MSI, Customer Cord, Postnet, Postnet UPC add -on code, Bookland, USPS code, GS1DataBaromnidInidirectional, GS1Databartruncated, GS1DataBarstacked, GS1DataBarstackedomnidialECTIONIR, G S1Databarlimited, GS1DATABAREXPANDED, GS1DATABAREXPANDEDSTACKED | Peak time ( * 2): 190va/180W (30 % printing) When standing: 27va/22W | Standard/Cutter/Hakuri/Non -Sepa |
Click on the part number for more information about each product