EMC Test System EMI Total Test System MR2300 Radio Radio Box/Shield Box-My5310s
EMC Test System EMI Total Test System MR2300 Radio Radio Box/Shield Box-My5310SU
EMC Test System EMI Total Test System MR2300 Radio Radio Box/Shield Box-My5410
EMC Test System EMI Total Test System MR2300 Radio Radio Box/Shield Box-My5310
EMC Test System EMI Total Test System MR2300 Radio Radio Box/Shield Box-Micronics

EMC Test System EMI Total Test System MR2300 Radio Radio Box/Shield Box
Micronics


About This Product

Ideal for the preliminary match test "PRE-COMPLIANCE" for the EMI official test. Integrated system that combines our spectrum analyzer technology, radio dark box technology and antenna technology 1. 2 types of EMI exams ・ Radioactive obstruction noise test It can be measured in a bandwidth of 30MHz to 1 GHz using a radio wave box and a wide band antenna. * 1GHz ~ is optional. ・ Conductive obstruction noise test It can be measured in a 150kHz to 30MHz bandwidth using Lisn (line impedance stabilization circuit net). 2. identification of noise generating sources ・ Measures magnetic field measurement of PCB in the EUT By performing magnetic field measurement of the print circuit substrate using the optional magnetic field probe CP-2SA, the source of obstruction noise can be identified. 1. EMI Total Test System that does not require additional equipment ・ A total test system that has everything from an antenna, an EMI spectrum analyzer, LISN, and PC software for EMI, as well as a radio wave box. ・ No additional equipment is required. ・ In addition, a magnetic field probe (option) is provided as a problem solving tool. 2. Ultra -small, wide band antenna developed in -house ・ 578 (W) × 401 (H) × 250 (d) MM, which is ultra -small, developed an antenna of 30MHz to 1 GHz and wide bandwidth. ・ The miniaturization of the radio wave box has been realized by the miniaturization of the antenna.

  • Product

    EMC Test System EMI Total Test System MR2300 Radio Radio Box/Shield Box




*Please note that we may not be able to accommodate sample requests.

4 Models of EMC Test System EMI Total Test System MR2300 Radio Radio Box/Shield Box

Items marked with have different values ​​depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) 11 -seater elevator dimensions (depth) 11 -seater elevator dimensions (doorway) 11 -seater elevator dimensions (height) Coaxial connector Divided time size (height) Divided time size (width) Division of dimensions (depth) Door opening dimensions External dimensions (approx.) I/f Internal dimensions Radio absorber Radio absorption performance Shield performance Turntable gross weight option
EMC Test System EMI Total Test System MR2300 Radio Radio Box/Shield Box-Part Number-My5310s

My5310s

Available upon quote 1350mm 800mm 2300mm N (j) × 1 (for the lower left, for antenna) n (j) × 1 (lower right side) 1220mm 680mm 1080mm 510 (W) x 920 (H) mm 1350 (W) x 1220 (H) x 1080 (d) mm D-SUB25 pin x 1LAN x 1AC x 1 (250Vmax/10A) * AC100V when installing an electric turntable Approximately 1230 (W) x 915 (H) x 915 (d) mm Double structural ferrite tile 20db or more@35MHz ~ 2.2GHz 70dbtyp@2.2GHz Diameter 220mm/load capacity 10kg Approximately 460kg ・ Wide band antenna MAN101 ・ Electric turntable MT106
EMC Test System EMI Total Test System MR2300 Radio Radio Box/Shield Box-Part Number-My5310SU

My5310SU

Available upon quote 1350mm 800mm 2300mm Nx2 (right side 1, front left 1) 1320mm 680mm 1140mm Approximately 510 (W) x 920 (H) mm 1960 (W) x 1320 (H) x 1140 (D) mm AC x 1 (250v10AMAX) * AC100VLAN x 1D-SUB25 pin x 1 when electric turntable Approximately 1840 (W) x 915 (H) x 915 (d) mm Double structural ferrite tile 20db or more@35MHz ~ 2.2GHz 70dbtyp@2.2GHz φ500mm/load capacity 50kg/manual Approximately 650kg ・ Door to B unit 630,000 yen ・ Wide band antenna MAN101580,000 yen ・ Electric turntable MT106B1,390,000 yen
EMC Test System EMI Total Test System MR2300 Radio Radio Box/Shield Box-Part Number-My5410

My5410

Available upon quote - - - N (j) × 2 (left side) n (j) × 1 (for the right side / antenna) - - - Approximately 940 (W) x 1440 (H) mm 2364 (W) × 1902 (H) × 1424 (D) mm D-SUB25 pin x 1 (female) LAN x 1AC x 1 (250Vmax/10A) * AC100V when installing electric turntable Approximately 2170 (W) x 1450 (H) x 1230 (d) mm Double structural ferrite tile 20db or more @ 35MHz ~ 2GHz 65dbtyp@2.2GHz φ756mm/100kg (equal static load) Approximately 1100kg ・ Wide band antenna MAN101 ・ Electric turntable MT106
EMC Test System EMI Total Test System MR2300 Radio Radio Box/Shield Box-Part Number-My5310

My5310

Available upon quote - - - N (j) × 2 (left side) n (j) × 1 (for the right side / antenna) - - - Approximately 410 (W) x 710 (H) mm 1340 (W) x 1210 (H) x 1030 (d) mm D-SUB25 pin x 1 (female) LAN x 1AC x 1 (250Vmax/10A) * AC100V when installing electric turntable Approximately 1230 (W) x 915 (H) x 915 (d) mm Double structural ferrite tile 20db or more @ 35MHz to 2.2GHz - φ220mm/10kg (equal static load) Approximately 460kg ・ Wide bandwidth antenna MAN102 ・ Electric turntable MT106C