Product
Glove box system NEXGEN seriesHandling Company
Yamahachi Bussan Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Access aspect | Antichamber (pass box) dimensions | Antichamber operation | Applicable safety standards | Automatic pressure control in the box | Box purge function | Circulation blower | Fully automatic pressure control in the glove box | Gas purification equipment department | Gas purification equipment location | Gas purifier type | Glove box dimensions | Glove box type | Material of each part | Number of gloves | Number of purification agent columns | Overall approximate dimensions | Power supply | Safety automatic pressure control | Standard equipment/accessories/etc. | System control | System control, monitor and operation section | Usable Enclosed/supplied gas |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
VAC109536 |
Available upon quote | Single side (S) | W254×H254×L305mm (optional size available) | Manual (automatic) | CSA Std. C22.2 No.1010.1, UL61010-1, CE | Possible | Various program auto purge | Inverter type, optimal efficiency flow control, oxygen/moisture meter interlocking | Fully automatic pressure control inside the glove box with arbitrary settings within the upper and lower limit values, controllable by foot switch | Cartridge type gas purification system, equipped with oxygen and moisture independent control blower | Rear inside box | Cartridge type | W1,150×D762×H915mm | 1BOX | Main parts: SUS304, gloves: Butyl (standard) (various materials available as options) | 2 | Choice | W1,430×D850×H1,890mm | 100~110V, or single phase 200~220V, 50/60Hz | Various interlock functions for positive and negative pressure inside the glove box | Front LED lighting, butyl gloves, glove port cover for glove replacement, glove box organizer shelf (3-tier removable), glove box outlet, various interface ports, vacuum pump (various) | NEXGEN-PLC | Control by Programmable Logic Controller (PLC), display/selection/setting by touch panel display | Argon, nitrogen, helium | |
VAC109740 |
Available upon quote | Single side (S) | W254×H254×L305mm (optional size available) | Manual (automatic) | CSA Std. C22.2 No.1010.1, UL61010-1, CE | Possible | Various program auto purge | Inverter type, optimal efficiency flow control, oxygen/moisture meter interlocking | Fully automatic pressure control inside the glove box with arbitrary settings within the upper and lower limit values, controllable by foot switch | Cartridge type gas purification system, equipped with oxygen and moisture independent control blower | Rear inside box | Cartridge type | W1,730×D762×H915mm | 1.5BOX | Main parts: SUS304, gloves: Butyl (standard) (various materials available as options) | 3 | Choice | W2,010×D850×H1,890mm | 100~110V, or single phase 200~220V, 50/60Hz | Various interlock functions for positive and negative pressure inside the glove box | Front LED lighting, butyl gloves, glove port cover for glove replacement, glove box organizer shelf (3-tier removable), glove box outlet, various interface ports, vacuum pump (various) | NEXGEN-PLC | Control by Programmable Logic Controller (PLC), display/selection/setting by touch panel display | Argon, nitrogen, helium | |
VAC109741 |
Available upon quote | Single side (S) | W254×H254×L305mm (optional size available) | Manual (automatic) | CSA Std. C22.2 No.1010.1, UL61010-1, CE | Possible | Various program auto purge | Inverter type, optimal efficiency flow control, oxygen/moisture meter interlocking | Fully automatic pressure control inside the glove box with arbitrary settings within the upper and lower limit values, controllable by foot switch | Cartridge type gas purification system, equipped with oxygen and moisture independent control blower | Rear inside box | Cartridge type | W2,300×D762×H915mm | 2BOX | Main parts: SUS304, gloves: Butyl (standard) (various materials available as options) | 4 | Choice | W2,580×D850×H1,890mm | 100~110V, or single phase 200~220V, 50/60Hz | Various interlock functions for positive and negative pressure inside the glove box | Front LED lighting, butyl gloves, glove port cover for glove replacement, glove box organizer shelf (3-tier removable), glove box outlet, various interface ports, vacuum pump (various) | NEXGEN-PLC | Control by Programmable Logic Controller (PLC), display/selection/setting by touch panel display | Argon, nitrogen, helium | |
VAC109742 |
Available upon quote | Double-sided (D) | W254×H254×L305mm (optional size available) | Manual (automatic) | CSA Std. C22.2 No.1010.1, UL61010-1, CE | Possible | Various program auto purge | Inverter type, optimal efficiency flow control, oxygen/moisture meter interlocking | Fully automatic pressure control inside the glove box with arbitrary settings within the upper and lower limit values, controllable by foot switch | Cartridge type gas purification system, equipped with oxygen and moisture independent control blower | Rear inside box | Cartridge type | W1,150×D1,150×H915mm | 1BOX | Main parts: SUS304, gloves: Butyl (standard) (various materials available as options) | 4 | Choice | W1,430×D1,240×H1,890mm | 100~110V, or single phase 200~220V, 50/60Hz | Various interlock functions for positive and negative pressure inside the glove box | Front LED lighting, butyl gloves, glove port cover for glove replacement, glove box organizer shelf (3-tier removable), glove box outlet, various interface ports, vacuum pump (various) | NEXGEN-PLC | Control by Programmable Logic Controller (PLC), display/selection/setting by touch panel display | Argon, nitrogen, helium | |
VAC109743 |
Available upon quote | Double-sided (D) | W254×H254×L305mm (optional size available) | Manual (automatic) | CSA Std. C22.2 No.1010.1, UL61010-1, CE | Possible | Various program auto purge | Inverter type, optimal efficiency flow control, oxygen/moisture meter interlocking | Fully automatic pressure control inside the glove box with arbitrary settings within the upper and lower limit values, controllable by foot switch | Cartridge type gas purification system, equipped with oxygen and moisture independent control blower | Rear inside box | Cartridge type | W1,730×D1,150×H915mm | 1.5BOX | Main parts: SUS304, gloves: Butyl (standard) (various materials available as options) | 6 | Choice | W2,010×D1,240×H1,890mm | 100~110V, or single phase 200~220V, 50/60Hz | Various interlock functions for positive and negative pressure inside the glove box | Front LED lighting, butyl gloves, glove port cover for glove replacement, glove box organizer shelf (3-tier removable), glove box outlet, various interface ports, vacuum pump (various) | NEXGEN-PLC | Control by Programmable Logic Controller (PLC), display/selection/setting by touch panel display | Argon, nitrogen, helium | |
VAC109744 |
Available upon quote | Double-sided (D) | W254×H254×L305mm (optional size available) | Manual (automatic) | CSA Std. C22.2 No.1010.1, UL61010-1, CE | Possible | Various program auto purge | Inverter type, optimal efficiency flow control, oxygen/moisture meter interlocking | Fully automatic pressure control inside the glove box with arbitrary settings within the upper and lower limit values, controllable by foot switch | Cartridge type gas purification system, equipped with oxygen and moisture independent control blower | Rear inside box | Cartridge type | W2,300×D1,150×H915mm | 2BOX | Main parts: SUS304, gloves: Butyl (standard) (various materials available as options) | 8 | Choice | W2,580×D1,240×H1,890mm | 100~110V, or single phase 200~220V, 50/60Hz | Various interlock functions for positive and negative pressure inside the glove box | Front LED lighting, butyl gloves, glove port cover for glove replacement, glove box organizer shelf (3-tier removable), glove box outlet, various interface ports, vacuum pump (various) | NEXGEN-PLC | Control by Programmable Logic Controller (PLC), display/selection/setting by touch panel display | Argon, nitrogen, helium |
Click on the part number for more information about each product