Glove box system OMNI-LAB series-VAC101965
Glove box system OMNI-LAB series-OMNI4PS
Glove box system OMNI-LAB series-VAC102282
Glove box system OMNI-LAB series-Yamahachi Bussan Co., Ltd.

Glove box system OMNI-LAB series
Yamahachi Bussan Co., Ltd.


About This Product

■Summary The OMNI-LAB glove box system is an automatic control glove box system based on OMNI-PLC, which is based on ``high performance'' and ``ease of use,'' provided by VAC in the United States. The 1BOX type was created by American company VAC, which has determined the most convenient basic size of a glove box based on many years of experience and design. Although it has a compact design, it incorporates all the necessary functions and has ample work space inside the box. The 2BOX type is the size of two 1BOX types. Not only can multiple processes and multiple samples be handled, but two people can perform separate tasks and experiments at the same time. In addition, it can be used in a wide range of applications, such as installing large equipment inside a box, building a chain system by combining it with external equipment, and multi-spec with numerous options installed. *1.5BOX, 3BOX or more types are also available. *3BOX type and other custom sizes can be produced as an option. ■Functions/Features 1. Glove box section This is an extremely easy-to-use glove box that utilizes VAC's long-standing know-how in its design and uses optimal materials. 2. Gas circulation purification equipment section By incorporating the purification device into the top of the glove box, various devices (evaporation device, electric furnace, cold/thermal insulation work containers, various storage containers, etc.) can be connected, combined, and installed at the bottom of the glove box. Sufficient capacity of purification agent and high-performance blower allow oxygen and moisture concentration in the glove box to be less than 1 ppm. In addition, all equipment is designed to require no cooling, and oxygen and moisture adsorption can occur at room temperature, so there is no need for a chiller or cooling water. 3. Centrally manage the system using OMNI-PLC control By selecting and configuring various menus on the touch panel display, all functions of the system can be set, and at the same time, the system status is displayed. 4. Fully automatic pressure control inside the glove box The pressure inside the glove box is automatically controlled within the arbitrarily set pressure range, and the set value and actual measured value are displayed on the display. 5. High performance blower Equipped with a silent high-flow inverter type blower. It is controlled by PLC and operates at optimal efficiency flow rate. *There are other features as well.

  • Product

    Glove box system OMNI-LAB series

Share this product


220+ people viewing

Last viewed: 3 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

3 Models of Glove box system OMNI-LAB series

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Access aspect Anti-chamber ultimate vacuum/door specifications Antichamber (pass box) dimensions Antichamber operation Applicable safety standards Automatic pressure control in the box Box purge function Circulation blower Circulation filter Fully automatic pressure control in the glove box Gas purification equipment location Gas purifier type Glove box dimensions Glove box type Material of each part Number of gloves Number of purification agent columns Overall approximate dimensions Power supply Purification agent column fully automatic regeneration process management Safety automatic pressure control Standard equipment/accessories/etc. System control System control, monitor and operation section Usable Enclosed/supplied gas
Glove box system OMNI-LAB series-Part Number-VAC101965

VAC101965

Available upon quote Single side (S) 10^-5Pa or less/O-ring seal, counterweight included, center clamp type handle, one-action opening/closing mechanism Large (cylindrical): φ380×L600mm, small (cylindrical): φ150×L300mm (optional sizes available) Manual CSA Std. C22.2 No.1010.1, UL61010-1, CE Possible Negative pressure monitoring purge (auto time purge) Inverter type, built-in thermoswitch, low noise (quiet type), no need for cooling water or chiller, UL, CSA standard certified product, optimum efficiency flow rate operation Equipped with HEPA (0.3μm) and filter circulation system entrance and exit Fully automatic pressure control inside the glove box with arbitrary settings within the upper and lower limit values, controllable by foot switch Top of box Renewable type W1,150×D762×H915mm 1BOX Main part: SUS304, window part: Lexan, glove: butyl (standard) (various materials available as options) 2 1 W1,950×D850×H2,120mm 100V, 15A or single phase 200V, 10A Fully automatic regeneration, standard regeneration cycle (approx. 12 hours), regeneration cycle for organic solvent removal (approx. 15 hours) Various interlock functions for positive and negative pressure inside the glove box Front LED lighting, butyl gloves, glove port cover for glove replacement, glove box organizer shelf (3-tier removable), glove box outlet, various interface ports, vacuum pump (various) OMNI-PLC Control by Programmable Logic Controller (PLC), display/selection/setting by touch panel display Argon, nitrogen, helium
Glove box system OMNI-LAB series-Part Number-OMNI4PS

OMNI4PS

Available upon quote Single side (S) 10^-5Pa or less/O-ring seal, counterweight included, center clamp type handle, one-action opening/closing mechanism Large (cylindrical): φ380×L600mm, small (cylindrical): φ150×L300mm (optional sizes available) Manual CSA Std. C22.2 No.1010.1, UL61010-1, CE Possible Negative pressure monitoring purge (auto time purge) Inverter type, built-in thermoswitch, low noise (quiet type), no need for cooling water or chiller, UL, CSA standard certified product, optimum efficiency flow rate operation Equipped with HEPA (0.3μm) and filter circulation system entrance and exit Fully automatic pressure control inside the glove box with arbitrary settings within the upper and lower limit values, controllable by foot switch Top of box Renewable type W1,780×D762×H915mm 1.5BOX Main part: SUS304, window part: Lexan, glove: butyl (standard) (various materials available as options) 4 1 W2,580×D850×H2,120mm 100V, 15A or single phase 200V, 10A Fully automatic regeneration, standard regeneration cycle (approx. 12 hours), regeneration cycle for organic solvent removal (approx. 15 hours) Various interlock functions for positive and negative pressure inside the glove box Front LED lighting, butyl gloves, glove port cover for glove replacement, glove box organizer shelf (3-tier removable), glove box outlet, various interface ports, vacuum pump (various) OMNI-PLC Control by Programmable Logic Controller (PLC), display/selection/setting by touch panel display Argon, nitrogen, helium
Glove box system OMNI-LAB series-Part Number-VAC102282

VAC102282

Available upon quote Single side (S) 10^-5Pa or less/O-ring seal, counterweight included, center clamp type handle, one-action opening/closing mechanism Large (cylindrical): φ380×L600mm, small (cylindrical): φ150×L300mm (optional sizes available) Manual CSA Std. C22.2 No.1010.1, UL61010-1, CE Possible Negative pressure monitoring purge (auto time purge) Inverter type, built-in thermoswitch, low noise (quiet type), no need for cooling water or chiller, UL, CSA standard certified product, optimum efficiency flow rate operation Equipped with HEPA (0.3μm) and filter circulation system entrance and exit Fully automatic pressure control inside the glove box with arbitrary settings within the upper and lower limit values, controllable by foot switch Top of box Renewable type W2,300×D762×H915mm 2BOX Main part: SUS304, window part: Lexan, glove: butyl (standard) (various materials available as options) 4 1 W3,100×D850×H2,120mm 100V, 15A or single phase 200V, 10A Fully automatic regeneration, standard regeneration cycle (approx. 12 hours), regeneration cycle for organic solvent removal (approx. 15 hours) Various interlock functions for positive and negative pressure inside the glove box Front LED lighting, butyl gloves, glove port cover for glove replacement, glove box organizer shelf (3-tier removable), glove box outlet, various interface ports, vacuum pump (various) OMNI-PLC Control by Programmable Logic Controller (PLC), display/selection/setting by touch panel display Argon, nitrogen, helium

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Yamahachi Bussan Co., Ltd.


View more products of Yamahachi Bussan Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree