Glove box system NEXUSⅡ series-VAC105320
Glove box system NEXUSⅡ series-VAC105324
Glove box system NEXUSⅡ series-VAC105328
Glove box system NEXUSⅡ series-Yamahachi Bussan Co., Ltd.

Glove box system NEXUSⅡ series
Yamahachi Bussan Co., Ltd.


About This Product

■Summary NEXUSⅡ (NexusⅡ) glove box system is a fully automatic control glove box system using NEXUSⅡ-PLC, which is based on "high performance" and "ease of use" and is provided by American company VAC. The 1BOX type was created by American company VAC, which has determined the most convenient basic size of a glove box based on many years of experience and design. Although it has a compact design, it incorporates all the necessary functions and has ample work space inside the box. The 2BOX type is the size of two 1BOX types. Not only can multiple processes and multiple samples be handled, but 2 to 4 people can perform separate tasks and experiments at the same time. In addition, it can be used in a wide range of applications, such as installing large equipment inside a box, building a chain system by combining it with external equipment, and multi-spec with numerous options installed. *1.5BOX, 3BOX or more types are also available. *3BOX type and other custom sizes can be produced as an option. ■Functions/Features 1. Glove box section This is an extremely easy-to-use glove box that utilizes VAC's long-standing know-how in its design and uses optimal materials. 2. Gas circulation purification equipment section The entire system has been made more compact by incorporating a purification device into the rear of the glove box frame. Sufficient capacity of purification agent and high-performance blower allow oxygen and moisture concentration in the glove box to be less than 1 ppm. In addition, all equipment is designed to require no cooling, and oxygen and moisture adsorption can occur at room temperature, so there is no need for a chiller or cooling water. 3. Centrally manage the system using NEXUSⅡ-PLC control All functions of the system can be set by selecting and setting various menus on the touch panel display, and at the same time, the system status is displayed. 4. Fully automatic pressure control inside the glove box The pressure inside the glove box is automatically controlled within the arbitrarily set pressure range, and the set value and actual measured value are displayed on the display. 5. High performance blower (with auto blower function) Adopts a silent type NEXUS II-PLC controlled high flow rate inverter blower. It works automatically in conjunction with the oxygen concentration meter and moisture concentration meter, constantly calculating the optimal efficient flow rate (blower speed) to maintain the set concentration. *Other model numbers are available.

  • Product

    Glove box system NEXUSⅡ series

Share this product


520+ people viewing


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

10 Models of Glove box system NEXUSⅡ series

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Access aspect Anti-chamber ultimate vacuum/door specifications Antichamber (pass box) dimensions Antichamber operation Applicable safety standards Automatic pressure control in the box Box purge function Circulation blower Circulation filter Fully automatic pressure control in the glove box Gas purification equipment location Gas purifier type Glove box dimensions Glove box type Material of each part Number of gloves Number of purification agent columns Overall approximate dimensions Power supply Purification agent column fully automatic regeneration process management Safety automatic pressure control Standard equipment/accessories/etc. System control System control, monitor and operation section Usable Enclosed/supplied gas
Glove box system NEXUSⅡ series-Part Number-VAC105320

VAC105320

Available upon quote Single side (S) 10^-5Pa or less/O-ring seal, counterweight included, center clamp type handle, one-action opening/closing mechanism Large (cylindrical): φ380×L600mm, small (cylindrical): φ150×L300mm (optional sizes available) Fully automatic CSA Std. C22.2 No.1010.1, UL61010-1, CE Possible Various program auto purge Inverter type, built-in thermoswitch, low noise (quiet type), no cooling water or chiller required, UL, CSA standard certified product, optimum efficiency flow control, oxygen concentration meter/moisture concentration meter interlocking control function Equipped with HEPA (0.3μm) and filter circulation system entrance and exit Fully automatic pressure control inside the glove box with arbitrary settings within the upper and lower limit values, controllable by foot switch Rear part of the box frame Renewable type W1,150×D762×H915mm 1BOX Main part: SUS304, window part: Lexan, glove: butyl (standard) (various materials available as options) 2 1 W1,950×D850×H1,890mm 100V, 15A or single phase 200V, 10A Fully automatic regeneration, standard regeneration cycle (approx. 12 hours), regeneration cycle for organic solvent removal (approx. 15 hours) Various interlock functions for positive and negative pressure inside the glove box Front LED lighting, butyl gloves, vacuum glove port cover for glove replacement, glove box organizer shelf (3-tier removable), glove box outlet, various interface ports, vacuum pump (various) NEXUSⅡ-PLC NEXUSⅡ program integrated control using Programmable Logic Controller (PLC), display/selection/setting via touch panel display Argon, nitrogen, helium
Glove box system NEXUSⅡ series-Part Number-VAC105322

VAC105322

Available upon quote Single side (S) 10^-5Pa or less/O-ring seal, counterweight included, center clamp type handle, one-action opening/closing mechanism Large (cylindrical): φ380×L600mm, small (cylindrical): φ150×L300mm (optional sizes available) Fully automatic CSA Std. C22.2 No.1010.1, UL61010-1, CE Possible Various program auto purge Inverter type, built-in thermoswitch, low noise (quiet type), no cooling water or chiller required, UL, CSA standard certified product, optimum efficiency flow control, oxygen concentration meter/moisture concentration meter interlocking control function Equipped with HEPA (0.3μm) and filter circulation system entrance and exit Fully automatic pressure control inside the glove box with arbitrary settings within the upper and lower limit values, controllable by foot switch Rear part of the box frame Renewable type W1,150×D762×H915mm 1BOX Main part: SUS304, window part: Lexan, glove: butyl (standard) (various materials available as options) 2 2 W1,950×D850×H1,890mm 100V, 15A or single phase 200V, 10A Fully automatic regeneration, standard regeneration cycle (approx. 12 hours), regeneration cycle for organic solvent removal (approx. 15 hours) Various interlock functions for positive and negative pressure inside the glove box Front LED lighting, butyl gloves, vacuum glove port cover for glove replacement, glove box organizer shelf (3-tier removable), glove box outlet, various interface ports, vacuum pump (various) NEXUSⅡ-PLC NEXUSⅡ program integrated control using Programmable Logic Controller (PLC), display/selection/setting via touch panel display Argon, nitrogen, helium
Glove box system NEXUSⅡ series-Part Number-VAC105324

VAC105324

Available upon quote Single side (S) 10^-5Pa or less/O-ring seal, counterweight included, center clamp type handle, one-action opening/closing mechanism Large (cylindrical): φ380×L600mm, small (cylindrical): φ150×L300mm (optional sizes available) Fully automatic CSA Std. C22.2 No.1010.1, UL61010-1, CE Possible Various program auto purge Inverter type, built-in thermoswitch, low noise (quiet type), no cooling water or chiller required, UL, CSA standard certified product, optimum efficiency flow control, oxygen concentration meter/moisture concentration meter interlocking control function Equipped with HEPA (0.3μm) and filter circulation system entrance and exit Fully automatic pressure control inside the glove box with arbitrary settings within the upper and lower limit values, controllable by foot switch Rear part of the box frame Renewable type W1,730×D762×H915mm 1.5BOX Main part: SUS304, window part: Lexan, glove: butyl (standard) (various materials available as options) 3 1 W2,530×D850×H1,890mm 100V, 15A or single phase 200V, 10A Fully automatic regeneration, standard regeneration cycle (approx. 12 hours), regeneration cycle for organic solvent removal (approx. 15 hours) Various interlock functions for positive and negative pressure inside the glove box Front LED lighting, butyl gloves, vacuum glove port cover for glove replacement, glove box organizer shelf (3-tier removable), glove box outlet, various interface ports, vacuum pump (various) NEXUSⅡ-PLC NEXUSⅡ program integrated control using Programmable Logic Controller (PLC), display/selection/setting via touch panel display Argon, nitrogen, helium
Glove box system NEXUSⅡ series-Part Number-VAC105326

VAC105326

Available upon quote Single side (S) 10^-5Pa or less/O-ring seal, counterweight included, center clamp type handle, one-action opening/closing mechanism Large (cylindrical): φ380×L600mm, small (cylindrical): φ150×L300mm (optional sizes available) Fully automatic CSA Std. C22.2 No.1010.1, UL61010-1, CE Possible Various program auto purge Inverter type, built-in thermoswitch, low noise (quiet type), no cooling water or chiller required, UL, CSA standard certified product, optimum efficiency flow control, oxygen concentration meter/moisture concentration meter interlocking control function Equipped with HEPA (0.3μm) and filter circulation system entrance and exit Fully automatic pressure control inside the glove box with arbitrary settings within the upper and lower limit values, controllable by foot switch Rear part of the box frame Renewable type W1,730×D762×H915mm 1.5BOX Main part: SUS304, window part: Lexan, glove: butyl (standard) (various materials available as options) 3 2 W2,530×D850×H1,890mm 100V, 15A or single phase 200V, 10A Fully automatic regeneration, standard regeneration cycle (approx. 12 hours), regeneration cycle for organic solvent removal (approx. 15 hours) Various interlock functions for positive and negative pressure inside the glove box Front LED lighting, butyl gloves, vacuum glove port cover for glove replacement, glove box organizer shelf (3-tier removable), glove box outlet, various interface ports, vacuum pump (various) NEXUSⅡ-PLC NEXUSⅡ program integrated control using Programmable Logic Controller (PLC), display/selection/setting via touch panel display Argon, nitrogen, helium
Glove box system NEXUSⅡ series-Part Number-VAC105328

VAC105328

Available upon quote Single side (S) 10^-5Pa or less/O-ring seal, counterweight included, center clamp type handle, one-action opening/closing mechanism Large (cylindrical): φ380×L600mm, small (cylindrical): φ150×L300mm (optional sizes available) Fully automatic CSA Std. C22.2 No.1010.1, UL61010-1, CE Possible Various program auto purge Inverter type, built-in thermoswitch, low noise (quiet type), no cooling water or chiller required, UL, CSA standard certified product, optimum efficiency flow control, oxygen concentration meter/moisture concentration meter interlocking control function Equipped with HEPA (0.3μm) and filter circulation system entrance and exit Fully automatic pressure control inside the glove box with arbitrary settings within the upper and lower limit values, controllable by foot switch Rear part of the box frame Renewable type W2,300×D762×H915mm 2BOX Main part: SUS304, window part: Lexan, glove: butyl (standard) (various materials available as options) 4 1 W3,100×D850×H1,890mm 100V, 15A or single phase 200V, 10A Fully automatic regeneration, standard regeneration cycle (approx. 12 hours), regeneration cycle for organic solvent removal (approx. 15 hours) Various interlock functions for positive and negative pressure inside the glove box Front LED lighting, butyl gloves, vacuum glove port cover for glove replacement, glove box organizer shelf (3-tier removable), glove box outlet, various interface ports, vacuum pump (various) NEXUSⅡ-PLC NEXUSⅡ program integrated control using Programmable Logic Controller (PLC), display/selection/setting via touch panel display Argon, nitrogen, helium
Glove box system NEXUSⅡ series-Part Number-VAC105330

VAC105330

Available upon quote Single side (S) 10^-5Pa or less/O-ring seal, counterweight included, center clamp type handle, one-action opening/closing mechanism Large (cylindrical): φ380×L600mm, small (cylindrical): φ150×L300mm (optional sizes available) Fully automatic CSA Std. C22.2 No.1010.1, UL61010-1, CE Possible Various program auto purge Inverter type, built-in thermoswitch, low noise (quiet type), no cooling water or chiller required, UL, CSA standard certified product, optimum efficiency flow control, oxygen concentration meter/moisture concentration meter interlocking control function Equipped with HEPA (0.3μm) and filter circulation system entrance and exit Fully automatic pressure control inside the glove box with arbitrary settings within the upper and lower limit values, controllable by foot switch Rear part of the box frame Renewable type W2,300×D762×H915mm 2BOX Main part: SUS304, window part: Lexan, glove: butyl (standard) (various materials available as options) 4 2 W3,100×D850×H1,890mm 100V, 15A or single phase 200V, 10A Fully automatic regeneration, standard regeneration cycle (approx. 12 hours), regeneration cycle for organic solvent removal (approx. 15 hours) Various interlock functions for positive and negative pressure inside the glove box Front LED lighting, butyl gloves, vacuum glove port cover for glove replacement, glove box organizer shelf (3-tier removable), glove box outlet, various interface ports, vacuum pump (various) NEXUSⅡ-PLC NEXUSⅡ program integrated control using Programmable Logic Controller (PLC), display/selection/setting via touch panel display Argon, nitrogen, helium
Glove box system NEXUSⅡ series-Part Number-VAC105332

VAC105332

Available upon quote Double-sided (D) 10^-5Pa or less/O-ring seal, counterweight included, center clamp type handle, one-action opening/closing mechanism Large (cylindrical): φ380×L600mm, small (cylindrical): φ150×L300mm (optional sizes available) Fully automatic CSA Std. C22.2 No.1010.1, UL61010-1, CE Possible Various program auto purge Inverter type, built-in thermoswitch, low noise (quiet type), no cooling water or chiller required, UL, CSA standard certified product, optimum efficiency flow control, oxygen concentration meter/moisture concentration meter interlocking control function Equipped with HEPA (0.3μm) and filter circulation system entrance and exit Fully automatic pressure control inside the glove box with arbitrary settings within the upper and lower limit values, controllable by foot switch Rear part of the box frame Renewable type W1,150×D1,150×H915mm 1BOX Main part: SUS304, window part: Lexan, glove: butyl (standard) (various materials available as options) 4 1 W1,950×D1,240×H1,890mm 100V, 15A or single phase 200V, 10A Fully automatic regeneration, standard regeneration cycle (approx. 12 hours), regeneration cycle for organic solvent removal (approx. 15 hours) Various interlock functions for positive and negative pressure inside the glove box Front LED lighting, butyl gloves, vacuum glove port cover for glove replacement, glove box organizer shelf (3-tier removable), glove box outlet, various interface ports, vacuum pump (various) NEXUSⅡ-PLC NEXUSⅡ program integrated control using Programmable Logic Controller (PLC), display/selection/setting via touch panel display Argon, nitrogen, helium
Glove box system NEXUSⅡ series-Part Number-VAC105334

VAC105334

Available upon quote Double-sided (D) 10^-5Pa or less/O-ring seal, counterweight included, center clamp type handle, one-action opening/closing mechanism Large (cylindrical): φ380×L600mm, small (cylindrical): φ150×L300mm (optional sizes available) Fully automatic CSA Std. C22.2 No.1010.1, UL61010-1, CE Possible Various program auto purge Inverter type, built-in thermoswitch, low noise (quiet type), no cooling water or chiller required, UL, CSA standard certified product, optimum efficiency flow control, oxygen concentration meter/moisture concentration meter interlocking control function Equipped with HEPA (0.3μm) and filter circulation system entrance and exit Fully automatic pressure control inside the glove box with arbitrary settings within the upper and lower limit values, controllable by foot switch Rear part of the box frame Renewable type W1,150×D1,150×H915mm 1BOX Main part: SUS304, window part: Lexan, glove: butyl (standard) (various materials available as options) 4 2 W1,950×D1,240×H1,890mm 100V, 15A or single phase 200V, 10A Fully automatic regeneration, standard regeneration cycle (approx. 12 hours), regeneration cycle for organic solvent removal (approx. 15 hours) Various interlock functions for positive and negative pressure inside the glove box Front LED lighting, butyl gloves, vacuum glove port cover for glove replacement, glove box organizer shelf (3-tier removable), glove box outlet, various interface ports, vacuum pump (various) NEXUSⅡ-PLC NEXUSⅡ program integrated control using Programmable Logic Controller (PLC), display/selection/setting via touch panel display Argon, nitrogen, helium
Glove box system NEXUSⅡ series-Part Number-VAC105336

VAC105336

Available upon quote Double-sided (D) 10^-5Pa or less/O-ring seal, counterweight included, center clamp type handle, one-action opening/closing mechanism Large (cylindrical): φ380×L600mm, small (cylindrical): φ150×L300mm (optional sizes available) Fully automatic CSA Std. C22.2 No.1010.1, UL61010-1, CE Possible Various program auto purge Inverter type, built-in thermoswitch, low noise (quiet type), no cooling water or chiller required, UL, CSA standard certified product, optimum efficiency flow control, oxygen concentration meter/moisture concentration meter interlocking control function Equipped with HEPA (0.3μm) and filter circulation system entrance and exit Fully automatic pressure control inside the glove box with arbitrary settings within the upper and lower limit values, controllable by foot switch Rear part of the box frame Renewable type W1,730×D1,150×H915mm 1.5BOX Main part: SUS304, window part: Lexan, glove: butyl (standard) (various materials available as options) 6 1 W2,530×D1,240×H1,890mm 100V, 15A or single phase 200V, 10A Fully automatic regeneration, standard regeneration cycle (approx. 12 hours), regeneration cycle for organic solvent removal (approx. 15 hours) Various interlock functions for positive and negative pressure inside the glove box Front LED lighting, butyl gloves, vacuum glove port cover for glove replacement, glove box organizer shelf (3-tier removable), glove box outlet, various interface ports, vacuum pump (various) NEXUSⅡ-PLC NEXUSⅡ program integrated control using Programmable Logic Controller (PLC), display/selection/setting via touch panel display Argon, nitrogen, helium
Glove box system NEXUSⅡ series-Part Number-VAC105338

VAC105338

Available upon quote Double-sided (D) 10^-5Pa or less/O-ring seal, counterweight included, center clamp type handle, one-action opening/closing mechanism Large (cylindrical): φ380×L600mm, small (cylindrical): φ150×L300mm (optional sizes available) Fully automatic CSA Std. C22.2 No.1010.1, UL61010-1, CE Possible Various program auto purge Inverter type, built-in thermoswitch, low noise (quiet type), no cooling water or chiller required, UL, CSA standard certified product, optimum efficiency flow control, oxygen concentration meter/moisture concentration meter interlocking control function Equipped with HEPA (0.3μm) and filter circulation system entrance and exit Fully automatic pressure control inside the glove box with arbitrary settings within the upper and lower limit values, controllable by foot switch Rear part of the box frame Renewable type W1,730×D1,150×H915mm 1.5BOX Main part: SUS304, window part: Lexan, glove: butyl (standard) (various materials available as options) 6 2 W2,530×D1,240×H1,890mm 100V, 15A or single phase 200V, 10A Fully automatic regeneration, standard regeneration cycle (approx. 12 hours), regeneration cycle for organic solvent removal (approx. 15 hours) Various interlock functions for positive and negative pressure inside the glove box Front LED lighting, butyl gloves, vacuum glove port cover for glove replacement, glove box organizer shelf (3-tier removable), glove box outlet, various interface ports, vacuum pump (various) NEXUSⅡ-PLC NEXUSⅡ program integrated control using Programmable Logic Controller (PLC), display/selection/setting via touch panel display Argon, nitrogen, helium

Click on the part number for more information about each product