Providing the next -generation flash test ABA ABA-262567
Providing the next -generation flash test ABA ABA-Anton Paar GmbH

Providing the next -generation flash test ABA ABA
Anton Paar GmbH


About This Product

Anton Pearl's Arbell Sealed Cup Type Test Series (ABA 500, ABA 300) offers a next -generation flash point test. Based on ISO 13,736, ISO 1,516, ISO 1,523, etc., the fire point is easily identified. You can automatically and highly accurate samples such as jet fuel, solvent, fragrance, chemicals, etc. The innovative cooling option can measure the flash point within the temperature range of -35 to+130 ° C. Both models have excellent heating control and fulfilling functions for both models, allowing accurate flash points. The skillful equipment design has maximized productivity and adopts an electric igniter, which has the longest life in the market, to reduce costs. ■ Main functions ・ High quality components with the longest life in the market and winning awards ・ The most powerful and intuitive use of Abel's flash point test device in the market ・ Super flexible 2-in-1 cooling function corresponding to the wideest flash range in the market ・ Maximize the safety of operators and labs ・ All measurement data is completely automated in the necessary place ・ Abel flash point test device complies with all relevant standards

  • Product

    Providing the next -generation flash test ABA ABA




*Please note that we may not be able to accommodate sample requests.

2 Models of Providing the next -generation flash test ABA ABA

Items marked with have different values ​​depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Applicable range (flash point temperature) Handling unit Haze detection Input option Measuring method Pressure correction Proofreading Sample temperature Sample temperature range Statistical data Stirring speed Supply gas Temperature rising speed Type of dug cooling display interface memory option power supply safety size weight
Providing the next -generation flash test ABA ABA-Part Number-262567

262567

Available upon quote 10-110 ° C TFT touch screen | Space -saving design, | Manual elevation multi -functional head, | No exposed cable Automatic detection by thermoelectric pid USB keyboard / mouse / barcode reader (optional) EN ISO 13,736, IP 170 equilibrium procedure: EN ISO 1,523, IP 492, EN 924 | EN ISO 1,516, IP 491 More than 1,000 types of user definition test program Automatic correction of the flash point to atmospheric pressure Sample and block temperature, Starler rotation speed, internal pressure monitor calibration Automatic (PT100) -7 ~+110 ℃ Average, minimum, maximum, repetition, standard deviation, maximum deviation According to the standard or user definition Fire extinguisher (option): CO2 or N2 inert gas, injection pressure 400 ~ 500kpa According to the standard or user definition Electric (sealed heat ray) Fan support formula Perchae cooling technology 7 inch TFT, PCAP touch screen USB x 2, LAN x 1 Approximately 50,000 tests for 1GB capacity, 1,000 users can be saved Standard test inserts (brass or stainless steel), mini -cup inserts (brass or stainless steel), calibration set, draft shield, fire extinguisher 100 ~ 240V, 50/60Hz, 300W Overheat prevention, automatic suspension | User management by optional automatic fire extinguishing system and unique optical fire detection system, access level by access level 262 x 472 x 437mm (width x depth x height) Approximately 14kg
Providing the next -generation flash test ABA ABA-Part Number-262566

262566

Available upon quote Air cooling 10 ~ 130 ℃ liquid cooling -30 ~+130 ° C TFT touch screen | Space -saving design, | Manual elevation multi -functional head, | No exposed cable Automatic detection by thermoelectric pid USB keyboard / mouse / barcode reader (optional) EN ISO 13,736, IP 170 equilibrium procedure: EN ISO 1,523, IP 492, EN 924 | EN ISO 1,516, IP 491 More than 1,000 types of user definition test program Automatic correction of the flash point to atmospheric pressure Sample and block temperature, Starler rotation speed, internal pressure monitor calibration Automatic (PT100) Air cooling 7 ~ 130 ℃ liquid cooling -35 ~+130 ° C Average, minimum, maximum, repetition, standard deviation, maximum deviation According to the standard or user definition Fire extinguisher (built -in): CO2 or N2 inert gas, injection pressure 400 ~ 500kpa
Gas ignition (option): 50MBar propane or butan
According to the standard or user definition Electric (sealed heat wire), gas ignition (optional) Fan / Liquid support Peltier cooling technology 7 inch TFT, PCAP touch screen USB x 4, LAN x 1 Approximately 50,000 tests for 1GB capacity, 1,000 users can be saved Standard test insert (brass or stainless steel), mini -cup insert (brass or stainless steel), calibration set, draft shield, gas type igniter 100 ~ 240V, 50/60Hz, 300W Overheat prevention, automatic suspension | Detects "flash" outside the cup, combinations of automatic fire extinguishing systems and unique optical fire detection systems, user management by access level 262 x 497 x 477mm (width x depth x height) Approximately 15kg

Click on the part number for more information about each product

Other products of Anton Paar GmbH


View more products of Anton Paar GmbH

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree