Selectors total oxygen in container from cans, bottles, and plastic bottles TPO 5000-197396
Selectors total oxygen in container from cans, bottles, and plastic bottles TPO 5000-Anton Paar GmbH

Selectors total oxygen in container from cans, bottles, and plastic bottles TPO 5000
Anton Paar GmbH


About This Product

■ Features ・ Selectally measure the total oxygen in the container from cans, bottles, and plastic bottles ・ Acquire results within 4 minutes ・ Self -cleaning minimal maintenance ・ Module type extension that can add up to 50 industrial measurement parameters ■ Low maintenance, ease of handling ・ Equipped with self -cleaning function to reduce the trouble of care ・ Automatic dedicated cleaning process ・ Easy to position general beverage containers ・ Self -cleaning function for all types of bottles/cans ・ It can be easily filled with bottles, plastic bottles, cans, and large -diameter sample containers ・ The latest photochemical oxygen sensor minimizes maintenance work ■ Design assuming use at production sites ・ Water droplet protection ・ Understand the status of the device at a glance by the easy -to -see status light ・ Realize the highest stability by sturdy legs and stainless steel housing ・ Easy to use even if you wear gloves ・ It can be handled appropriately with a fulfilling safety function ■ Up to 15 times per hour -Easy to execute ・ The result can be obtained in just 4 minutes ・ 7 -inch touch screen equipped with intuitive and highly responsive user interface ・ By customizing the home screen, you can immediately call frequently used functions. ・ Confirmation and adjustment of complete traceability and known concentration with zero points ・ Save up to 5,000 measurement data ■ Simultaneous measurement of TPO and CO2 ・ Automatically filling the carbon dioxide carboqc of Anton Pearl ・ Easy to clean all devices just by clicking the button ・ Up to 4 parameters of total oxygen in the container, oxygen in head space, dissolved O₂, and CO₂ can be measured at once * 1. If the carbonated level exceeds 5.5 g/L, it is 35 ° C, and if the carbonated level exceeds 10g/l, it is 10 ° C. * When the peripheral temperature and the sample temperature are 23 ° C and the standard cleaning is applied. The first measurement of one set does not consider the judgment of the reproducibility of the set. * 3 If the relative humidity is high, a purge of the device by dried air is required. * 4 TPO only, more than 300ml for TPO and Carboqc. * 5 Other container types will be handled according to your request. Other sample types will also respond according to your request. * 6 If there is no compressed air connection, anaerobic gas can be used.

  • Product

    Selectors total oxygen in container from cans, bottles, and plastic bottles TPO 5000




*Please note that we may not be able to accommodate sample requests.

1 Models of Selectors total oxygen in container from cans, bottles, and plastic bottles TPO 5000

Product Image Part Number Price (excluding tax) Additional gas * 6 Communication interface Container height Container volume * 4 Diameter of the container Dimensions (depth x width x height) Dissolved oxygen Environmental conditions peripheral temperature Environmental conditions relative humidity (without condensation) * 3 Gas consumption/measurement I need anaerobic gas Oxygen in the gas phase Protection grade Repeated accuracy * 2 TPO Save data Temperature * 1 Tested container/sample * 5 Aluminum cans Tested container/sample * 5 Corkless glass bottle Tested container/sample * 5 PET bottles Tested container/sample * 5 aluminum bottle Tested container/sample * 5 typical samples Washing display elevation power supply pressure weight
Selectors total oxygen in container from cans, bottles, and plastic bottles TPO 5000-Part Number-197396

197396

Available upon quote Compressed air, 5-6.5bar (absolute pressure), oil -free USB x 3, Ethernet, CAN (Anton Pearl only), RS232 30 ~ 370mm 150 ~ 2,000ml 35 ~ 90mm 515 x 590 x 1,120mm A trace range sensor: 0 ~ 2ppm
Wide -ranged sensor: 0 ~ 45ppm
15 ~ 35 ° C, 0 to 40 ° C (corresponding to requests) 10 ~ 90% Vn = 8L N2 or CO2 Class 5 (when using TPO 5,000 without CO2 measurement), 5 to 6.2 Bar (absolute pressure), no fluctuation (± 0.1bar) A trace range sensor: 0 ~ 45hpa
Wide -ranged sensor: 0 ~ 1,000hpa
IPX3 A trace range sensor: ± 8PPB or ± 6%larger
Wide range sensor: ± 25 ppb or ± 6%larger
Measurement data for up to 5,000 times Non -frozen sample: 0 to 40 ℃ 8 ounces, 10 oz, 12 ounces, 16 ounces, 25 ounces, 330ml, 500ml 12 oz, 14.5 oz, 18 oz, 22.4 oz, 24 oz, 24 ounces, 32 oz, 40 ounces, 250ml, 330ml, 750ml, 1,000 ml 42 oz, 1,000ml 14 oz, 2,000ml General style beer, carbonated water, water, cola. Fiber -free Tap water or processed water (chlorine free), 1.5 to 4.5bar (absolute pressure), regular special cleaning is required 7 inch LCD panel touch screen Up to 2,000m AC 85 ~ 264V, 45 ~ 66Hz or DC 88-370V 5 ~ 6.2bar (absolute pressure) 70