Product
Explosion -proof pressure / temperature data logger PR1000EX seriesHandling Company
Krone Co., Ltd.Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Battery life | Battery type | Calibration day | Compatible software | Conformity standard | IP standard | Logging interval | Material | Memory number | Operating system conformity | Overwritten mode | PC interface | Pressure range (PSI) | Pressure resolution (PSI) | Pressure response time | Proofreading | Proofreading accuracy | Real -time measurement | Repetition | Start logging | Temperature decomposition ability | Temperature range | Temperature sensor | Time accuracy | data form | pressure sensor | size | usage environment | weight |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
PR1000EX-1000A |
Available upon quote |
Usually one year (when logging is every 1 minute in 25 ° C environment) 10 days (in the case of transgent mode 128 Hz) |
3.6 V lithium batteries, batteries can be replaced by everyone | Automatic record for data logger | Standard Madgetech 4 Software 4.2.21.1 or later | CE | IP68 |
Free once every second to 24 hours Transement mode: 128 Hz |
316 Stainless steel/Redel resin | 1,396,736 | Windows 7, 8, 10 | Possible | IFC400 or IFC406 Docking Station is required | 0-1,000 PSIA | 0.02 PSIA | 0.1 m seconds (10 to 90%FSR) | Digital school from software |
± 2.0 ° C: 0 ℃ ~+50 ℃ ± 4.0 ° C: -40 ℃ ~ -1 ℃ ± 4.0 ° C: +51 ℃ ~ +85 ℃ |
Connect to a PC and monitor and record data in real time | ± 0.5% fsr; ± 0.2% (normal) | Start immediately from the software or program up to 6 months | 1.0 ℃ | -40 ℃ ~+80 ℃ | Semiconductor | ± 1 minute/month (for 25 ° C) | Date and time and time and time, ° f, k, ° r; mbar, psi, inhg, mmhg, atm, torr, pa, kpa, mpa, m | Semiconductor Strungage | Length 91.3 mm x diameter 24.6 mm |
-40 ℃ ~ +80 ℃ 0%RH ~ 100%RH |
156 | |
PR1000EX-100A |
Available upon quote |
Usually one year (when logging is every 1 minute in 25 ° C environment) 10 days (in the case of transgent mode 128 Hz) |
3.6 V lithium batteries, batteries can be replaced by everyone | Automatic record for data logger | Standard Madgetech 4 Software 4.2.21.1 or later | CE | IP68 |
Free once every second to 24 hours Transement mode: 128 Hz |
316 Stainless steel/Redel resin | 1,396,736 | Windows 7, 8, 10 | Possible | IFC400 or IFC406 Docking Station is required | 0-100 PSIA | 0.002 PSIA | 0.1 m seconds (10 to 90%FSR) | Digital school from software |
± 2.0 ° C: 0 ℃ ~+50 ℃ ± 4.0 ° C: -40 ℃ ~ -1 ℃ ± 4.0 ° C: +51 ℃ ~ +85 ℃ |
Connect to a PC and monitor and record data in real time | ± 0.5% fsr; ± 0.2% (normal) | Start immediately from the software or program up to 6 months | 1.0 ℃ | -40 ℃ ~+80 ℃ | Semiconductor | ± 1 minute/month (for 25 ° C) | Date and time and time and time, ° f, k, ° r; mbar, psi, inhg, mmhg, atm, torr, pa, kpa, mpa, m | Semiconductor Strungage | Length 91.3 mm x diameter 24.6 mm |
-40 ℃ ~ +80 ℃ 0%RH ~ 100%RH |
156 | |
PR1000EX-100G |
Available upon quote |
Usually one year (when logging is every 1 minute in 25 ° C environment) 10 days (in the case of transgent mode 128 Hz) |
3.6 V lithium batteries, batteries can be replaced by everyone | Automatic record for data logger | Standard Madgetech 4 Software 4.2.21.1 or later | CE | IP68 |
Free once every second to 24 hours Transement mode: 128 Hz |
316 Stainless steel/Redel resin | 1,396,736 | Windows 7, 8, 10 | Possible | IFC400 or IFC406 Docking Station is required | 0-100 PSIG | 0.002 PSIG | 0.1 m seconds (10 to 90%FSR) | Digital school from software |
± 2.0 ° C: 0 ℃ ~+50 ℃ ± 4.0 ° C: -40 ℃ ~ -1 ℃ ± 4.0 ° C: +51 ℃ ~ +85 ℃ |
Connect to a PC and monitor and record data in real time | ± 0.5% fsr; ± 0.2% (normal) | Start immediately from the software or program up to 6 months | 1.0 ℃ | -40 ℃ ~+80 ℃ | Semiconductor | ± 1 minute/month (for 25 ° C) | Date and time and time and time, ° f, k, ° r; mbar, psi, inhg, mmhg, atm, torr, pa, kpa, mpa, m | Semiconductor Strungage | Length 91.3 mm x diameter 24.6 mm |
-40 ℃ ~ +80 ℃ 0%RH ~ 100%RH |
156 | |
PR1000EX-300A |
Available upon quote |
Usually one year (when logging is every 1 minute in 25 ° C environment) 10 days (in the case of transgent mode 128 Hz) |
3.6 V lithium batteries, batteries can be replaced by everyone | Automatic record for data logger | Standard Madgetech 4 Software 4.2.21.1 or later | CE | IP68 |
Free once every second to 24 hours Transement mode: 128 Hz |
316 Stainless steel/Redel resin | 1,396,736 | Windows 7, 8, 10 | Possible | IFC400 or IFC406 Docking Station is required | 0-300 PSIA | 0.005 PSIA | 0.1 m seconds (10 to 90%FSR) | Digital school from software |
± 2.0 ° C: 0 ℃ ~+50 ℃ ± 4.0 ° C: -40 ℃ ~ -1 ℃ ± 4.0 ° C: +51 ℃ ~ +85 ℃ |
Connect to a PC and monitor and record data in real time | ± 0.5% fsr; ± 0.2% (normal) | Start immediately from the software or program up to 6 months | 1.0 ℃ | -40 ℃ ~+80 ℃ | Semiconductor | ± 1 minute/month (for 25 ° C) | Date and time and time and time, ° f, k, ° r; mbar, psi, inhg, mmhg, atm, torr, pa, kpa, mpa, m | Semiconductor Strungage | Length 91.3 mm x diameter 24.6 mm |
-40 ℃ ~ +80 ℃ 0%RH ~ 100%RH |
156 | |
PR1000EX-300G |
Available upon quote |
Usually one year (when logging is every 1 minute in 25 ° C environment) 10 days (in the case of transgent mode 128 Hz) |
3.6 V lithium batteries, batteries can be replaced by everyone | Automatic record for data logger | Standard Madgetech 4 Software 4.2.21.1 or later | CE | IP68 |
Free once every second to 24 hours Transement mode: 128 Hz |
316 Stainless steel/Redel resin | 1,396,736 | Windows 7, 8, 10 | Possible | IFC400 or IFC406 Docking Station is required | 0-300 PSIG | 0.005 PSIG | 0.1 m seconds (10 to 90%FSR) | Digital school from software |
± 2.0 ° C: 0 ℃ ~+50 ℃ ± 4.0 ° C: -40 ℃ ~ -1 ℃ ± 4.0 ° C: +51 ℃ ~ +85 ℃ |
Connect to a PC and monitor and record data in real time | ± 0.5% fsr; ± 0.2% (normal) | Start immediately from the software or program up to 6 months | 1.0 ℃ | -40 ℃ ~+80 ℃ | Semiconductor | ± 1 minute/month (for 25 ° C) | Date and time and time and time, ° f, k, ° r; mbar, psi, inhg, mmhg, atm, torr, pa, kpa, mpa, m | Semiconductor Strungage | Length 91.3 mm x diameter 24.6 mm |
-40 ℃ ~ +80 ℃ 0%RH ~ 100%RH |
156 | |
PR1000EX-30A |
Available upon quote |
Usually one year (when logging is every 1 minute in 25 ° C environment) 10 days (in the case of transgent mode 128 Hz) |
3.6 V lithium batteries, batteries can be replaced by everyone | Automatic record for data logger | Standard Madgetech 4 Software 4.2.21.1 or later | CE | IP68 |
Free once every second to 24 hours Transement mode: 128 Hz |
316 Stainless steel/Redel resin | 1,396,736 | Windows 7, 8, 10 | Possible | IFC400 or IFC406 Docking Station is required | 0-30 PSIA | 0.0005 PSIA | 0.1 m seconds (10 to 90%FSR) | Digital school from software |
± 2.0 ° C: 0 ℃ ~+50 ℃ ± 4.0 ° C: -40 ℃ ~ -1 ℃ ± 4.0 ° C: +51 ℃ ~ +85 ℃ |
Connect to a PC and monitor and record data in real time | ± 0.5% fsr; ± 0.2% (normal) | Start immediately from the software or program up to 6 months | 1.0 ℃ | -40 ℃ ~+80 ℃ | Semiconductor | ± 1 minute/month (for 25 ° C) | Date and time and time and time, ° f, k, ° r; mbar, psi, inhg, mmhg, atm, torr, pa, kpa, mpa, m | Semiconductor Strungage | Length 91.3 mm x diameter 24.6 mm |
-40 ℃ ~ +80 ℃ 0%RH ~ 100%RH |
156 | |
PR1000EX-30G |
Available upon quote |
Usually one year (when logging is every 1 minute in 25 ° C environment) 10 days (in the case of transgent mode 128 Hz) |
3.6 V lithium batteries, batteries can be replaced by everyone | Automatic record for data logger | Standard Madgetech 4 Software 4.2.21.1 or later | CE | IP68 |
Free once every second to 24 hours Transement mode: 128 Hz |
316 Stainless steel/Redel resin | 1,396,736 | Windows 7, 8, 10 | Possible | IFC400 or IFC406 Docking Station is required | 0-30 PSIG | 0.0005 PSIG | 0.1 m seconds (10 to 90%FSR) |
Digital school from software |
± 2.0 ° C: 0 ℃ ~+50 ℃ ± 4.0 ° C: -40 ℃ ~ -1 ℃ ± 4.0 ° C: +51 ℃ ~ +85 ℃ |
Connect to a PC and monitor and record data in real time | ± 0.5% fsr; ± 0.2% (normal) | Start immediately from the software or program up to 6 months | 1.0 ℃ | -40 ℃ ~+80 ℃ | Semiconductor | ± 1 minute/month (for 25 ° C) | Date and time and time and time, ° f, k, ° r; mbar, psi, inhg, mmhg, atm, torr, pa, kpa, mpa, m | Semiconductor Strungage | Length 91.3 mm x diameter 24.6 mm |
-40 ℃ ~ +80 ℃ 0%RH ~ 100%RH |
156 | |
PR1000EX-500A |
Available upon quote |
Usually one year (when logging is every 1 minute in 25 ° C environment) 10 days (in the case of transgent mode 128 Hz) |
3.6 V lithium batteries, batteries can be replaced by everyone | Automatic record for data logger | Standard Madgetech 4 Software 4.2.21.1 or later | CE | IP68 |
Free once every second to 24 hours Transement mode: 128 Hz |
316 Stainless steel/Redel resin | 1,396,736 | Windows 7, 8, 10 | Possible | IFC400 or IFC406 Docking Station is required | 0-500 PSIA | 0.01 PSIA | 0.1 m seconds (10 to 90%FSR) | Digital school from software |
± 2.0 ° C: 0 ℃ ~+50 ℃ ± 4.0 ° C: -40 ℃ ~ -1 ℃ ± 4.0 ° C: +51 ℃ ~ +85 ℃ |
Connect to a PC and monitor and record data in real time | ± 0.5% fsr; ± 0.2% (normal) | Start immediately from the software or program up to 6 months | 1.0 ℃ | -40 ℃ ~+80 ℃ | Semiconductor | ± 1 minute/month (for 25 ° C) | Date and time and time and time, ° f, k, ° r; mbar, psi, inhg, mmhg, atm, torr, pa, kpa, mpa, m | Semiconductor Strungage | Length 91.3 mm x diameter 24.6 mm |
-40 ℃ ~ +80 ℃ 0%RH ~ 100%RH |
156 | |
PR1000EX-500G |
Available upon quote |
Usually one year (when logging is every 1 minute in 25 ° C environment) 10 days (in the case of transgent mode 128 Hz) |
3.6 V lithium batteries, batteries can be replaced by everyone | Automatic record for data logger | Standard Madgetech 4 Software 4.2.21.1 or later | CE | IP68 |
Free once every second to 24 hours Transement mode: 128 Hz |
316 Stainless steel/Redel resin | 1,396,736 | Windows 7, 8, 10 | Possible | IFC400 or IFC406 Docking Station is required | 0-500 PSIG | 0.01 PSIG | 0.1 m seconds (10 to 90%FSR) | Digital school from software |
± 2.0 ° C: 0 ℃ ~+50 ℃ ± 4.0 ° C: -40 ℃ ~ -1 ℃ ± 4.0 ° C: +51 ℃ ~ +85 ℃ |
Connect to a PC and monitor and record data in real time | ± 0.5% fsr; ± 0.2% (normal) | Start immediately from the software or program up to 6 months | 1.0 ℃ | -40 ℃ ~+80 ℃ | Semiconductor | ± 1 minute/month (for 25 ° C) | Date and time and time and time, ° f, k, ° r; mbar, psi, inhg, mmhg, atm, torr, pa, kpa, mpa, m | Semiconductor Strungage | Length 91.3 mm x diameter 24.6 mm |
-40 ℃ ~ +80 ℃ 0%RH ~ 100%RH |
156 | |
PR1000EX-5000A |
$ 1,471.80〜 |
Usually one year (when logging is every 1 minute in 25 ° C environment) 10 days (in the case of transgent mode 128 Hz) |
3.6 V lithium batteries, batteries can be replaced by everyone | Automatic record for data logger | Standard Madgetech 4 Software 4.2.21.1 or later | CE | IP68 |
Free once every second to 24 hours Transement mode: 128 Hz |
316 Stainless steel/Redel resin | 1,396,736 | Windows 7, 8, 10 | Possible | IFC400 or IFC406 Docking Station is required | 0-5,000 PSIA | 0.1 PSIA | 0.1 m seconds (10 to 90%FSR) | Digital school from software |
± 2.0 ° C: 0 ℃ ~+50 ℃ ± 4.0 ° C: -40 ℃ ~ -1 ℃ ± 4.0 ° C: +51 ℃ ~ +85 ℃ |
Connect to a PC and monitor and record data in real time | ± 0.5% fsr; ± 0.2% (normal) | Start immediately from the software or program up to 6 months | 1.0 ℃ | -40 ℃ ~+80 ℃ | Semiconductor | ± 1 minute/month (for 25 ° C) | Date and time and time and time, ° f, k, ° r; mbar, psi, inhg, mmhg, atm, torr, pa, kpa, mpa, m | Semiconductor Strungage | Length 91.3 mm x diameter 24.6 mm |
-40 ℃ ~ +80 ℃ 0%RH ~ 100%RH |
156 |
Click on the part number for more information about each product