Digital output gas sensor I series-ISO2
Digital output gas sensor I series-IO2
Digital output gas sensor I series-ILEL
Digital output gas sensor I series-IH2S
Digital output gas sensor I series-ICO
Digital output gas sensor I series-Krone Co., Ltd.

Digital output gas sensor I series
Krone Co., Ltd.


About This Product

■ Overview ・ The next -generation high -performance sensor intelligent series (I series) is a gas sensor newly released by the brand CITY Technology. ・ The I series with a digital interface has a long life and has a built -in analysis function. ・ The intelligent high function of the I series can significantly improve the performance of the overall measurement device. -Since the failure can be displayed and the condition of the device can be monitored, the total costs can be reduced by reducing the time of interruption of work more smoothly, more safely, more. -A proofreading sensors can be easily mounted on equipment, so it is easy to use for users and is ideal for OEM manufacturers. ・ The built -in OEM lock code function can prevent the sensor replacement by a third party without authority. -The gas sensor I series that can achieve a long life of 5 years and can respond to a wide range of temperature and humidity changes can be used under a wide range of applications and various environmental conditions. -City Technology I series has acquired European explosion-proof standards (ATEX) and international standard explosion-proof standards (IECEX) (EN IEC 60079-0 and ENIEC 60079-11). ・ BS EN 45544-1, BSEN 50104, ANSI/ISA 92.00.01, ANSI/ISA 92.04.01, AS/NZS 4641, etc. are designed. ■ Supportable gas species ・ Electrochemical formula: carbon dioxide (CO), hydrogen sulfide (H2S), sulfur dioxide (SO2), oxygen (O2) ・ Catalyst beads: Lower explosion (LEL: LOWEREXPLOSION LIMIT) ■ Other features ・ Digital interface ・ Replace ・ Digital traceability ・ OEM lock function ・ Colored sensor ・ Notice of re -proofing time ・ Notice of exchange time ・ Detection of failure ・ Compact shape

  • Product

    Digital output gas sensor I series




*Please note that we may not be able to accommodate sample requests.

5 Models of Digital output gas sensor I series

Items marked with have different values ​​depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Feature Measured gas species Measurement accuracy Measurement range Operating temperature limit Performance standards Product life standard
Digital output gas sensor I series-Part Number-ISO2

ISO2

Available upon quote Supports long -term stability, wide range of temperature and humidity changes Sulfur dioxide (SO2) ± 5% 0 ~ 20 ppm -20 ~ 50 ℃ BS EN 45544-1 / BS EN 50104
Ansi / ISA 92.00.01 / ISA 92.04.01
AS / NZS 4641
About five years European explosion prevention standard (ATEX)
International standard explosion prevention standard (IECEX) authentication (EN IEC 60079-0 and ENIEC 60079-11)
Digital output gas sensor I series-Part Number-IO2

IO2

Available upon quote Supports long -term stability, wide range of temperature and humidity changes Oxygen (O2) ± 3% vol.o2 0 to 25% vol.o2 -40 ~ 60 ° C BS EN 45544-1 / BS EN 50104
Ansi / ISA 92.00.01 / ISA 92.04.01
AS / NZS 4641
About five years European explosion prevention standard (ATEX)
International standard explosion prevention standard (IECEX) authentication (EN IEC 60079-0 and ENIEC 60079-11)
Digital output gas sensor I series-Part Number-ILEL

ILEL

Available upon quote Supports long -term stability, wide range of temperature and humidity changes Flammable gas, lel 5% lel 0 to 100% LEL -20 ~ 60 ° C BS EN 45544-1 / BS EN 50104
Ansi / ISA 92.00.01 / ISA 92.04.01
AS / NZS 4641
About five years European explosion prevention standard (ATEX)
International standard explosion prevention standard (IECEX) authentication (EN IEC 60079-0 and ENIEC 60079-11)
Digital output gas sensor I series-Part Number-IH2S

IH2S

Available upon quote Supports long -term stability, wide range of temperature and humidity changes Hydrogen sulfide (H2S) ± 5% 0 ~ 200 ppm -40 ~ 60 ° C BS EN 45544-1 / BS EN 50104
Ansi / ISA 92.00.01 / ISA 92.04.01
AS / NZS 4641
About five years European explosion prevention standard (ATEX)
International standard explosion prevention standard (IECEX) authentication (EN IEC 60079-0 and ENIEC 60079-11)
Digital output gas sensor I series-Part Number-ICO

ICO

Available upon quote Supports long -term stability, wide range of temperature and humidity changes Carbon monoxide (CO) ± 5% 0 ~ 1000 ppm -40 ~ 60 ° C BS EN 45544-1 / BS EN 50104
Ansi / ISA 92.00.01 / ISA 92.04.01
AS / NZS 4641
About five years European explosion prevention standard (ATEX)
International standard explosion prevention standard (IECEX) authentication (EN IEC 60079-0 and ENIEC 60079-11)

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Krone Co., Ltd.


View more products of Krone Co., Ltd.

About Company Handling This Product

Krone Co., Ltd.

  • Japan
  • Since 1980

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.