Ultrasonic flow meter for clamp -on type tubes SONOFLOW CO.56/XXX-Co56/035
Ultrasonic flow meter for clamp -on type tubes SONOFLOW CO.56/XXX-Krone Co., Ltd.

Ultrasonic flow meter for clamp -on type tubes SONOFLOW CO.56/XXX
Krone Co., Ltd.


About This Product

■ Characteristics ・ SONOFLOW® is a sensor that can measure the flow rate and detect bubbles from the outside of the tube without the sensor contact the media. ・ It is suitable for applications in fields with severe hygiene standards, such as medical technology, biotechnology, pharmaceutical, chemistry, semiconductor industry, etc. ・ We support various applications by output and switching output. The RS-485 communication (SONOTEC protocol; Modbus® with software settings) realizes up to 12 sensors in a harsh environment. ■ Applications Measurement of flow rate of artificial cardiopulmonary and dialysis devices, etc.

  • Product

    Ultrasonic flow meter for clamp -on type tubes SONOFLOW CO.56/XXX

Share this product


310+ people viewing

Last viewed: 19 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

6 Models of Ultrasonic flow meter for clamp -on type tubes SONOFLOW CO.56/XXX

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Applicable tube outer diameter x inner diameter (mm) Body material Calibration fluid Current consumption current Dimension CH X CW (mm) Dimension L X W X H (HWH) (mm) Flow range (ML/Min) Fluid temperature/environmental temperature Measured fluid Measurement accuracy Medical standard Output signal Power-supply voltage Protection grade Reaction time Response time Sensor sensitivity Zero shift cable option storage temperature terms of use weight
Ultrasonic flow meter for clamp -on type tubes SONOFLOW CO.56/XXX-Part Number-Co56/035

Co56/035

Available upon quote 4.0 x 3.0 Measurement unit: PMMA
Housing: Aluminum (gray)
Cover: SUS304 (red)
Water (23 ± 2 ℃)
* Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request.
Up to 150 mA * current must be limited to 250mA with fuses. □ 3.5 44 x 44 x 28 300 ~ 3,000 10 to 50 ° C Water, saline, human blood, transparent liquid Straight line: ± 5 % RD, reproducibility: ± 2 % RD IEC 60601-1 3rd edition, EMC standard (IEC 60601-1-2 4th edition) RS-485 communication (SONOTEC protocol) 5 +0.5/-0.1VDC IP67 Up to 1.6 ms interval 10 Ms or less (faster response time is possible as needed) It detects bubbles over about 30 % of the inner diameter of the tube. ± 0.02 less than L/min (24 hours) 2.5 m Calibration certificate
SONOFLOW C3 Software (USB Data Converter / USB Cable Typea-B 2 M / USB Memory)
-20 ~ 70 ° C (10 to 95 % RH) * Dew condensation / freezing Tube material: PVC, Tube outer diameter: 4 to 16 mm 120
Ultrasonic flow meter for clamp -on type tubes SONOFLOW CO.56/XXX-Part Number-Co56/044

Co56/044

Available upon quote 5.0 x 3.0 Measurement unit: PMMA
Housing: Aluminum (gray)
Cover: SUS304 (red)
Water (23 ± 2 ℃)
* Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request.
Up to 150 mA * current must be limited to 250mA with fuses. □ 4.4 44 x 44 x 30 600 ~ 6,000 10 to 50 ° C Water, saline, human blood, transparent liquid Straight line: ± 5 % RD, reproducibility: ± 2 % RD IEC 60601-1 3rd edition, EMC standard (IEC 60601-1-2 4th edition) RS-485 communication (SONOTEC protocol) 5 +0.5/-0.1VDC IP67 Up to 1.6 ms interval 10 Ms or less (faster response time is possible as needed) It detects bubbles over about 30 % of the inner diameter of the tube. ± 0.02 less than L/min (24 hours) 2.5 m Calibration certificate
SONOFLOW C3 Software (USB Data Converter / USB Cable Typea-B 2 M / USB Memory)
-20 ~ 70 ° C (10 to 95 % RH) * Dew condensation / freezing Tube material: PVC, Tube outer diameter: 4 to 16 mm 125
Ultrasonic flow meter for clamp -on type tubes SONOFLOW CO.56/XXX-Part Number-Co56/060

Co56/060

Available upon quote 7.0 x 5.0 Measurement unit: PMMA
Housing: Aluminum (gray)
Cover: SUS304 (red)
Water (23 ± 2 ℃)
* Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request.
Up to 150 mA * current must be limited to 250mA with fuses. □ 6.0 44 x 44 x 32 800 ~ 8,000 10 to 50 ° C Water, saline, human blood, transparent liquid Straight line: ± 5 % RD, reproducibility: ± 2 % RD IEC 60601-1 3rd edition, EMC standard (IEC 60601-1-2 4th edition) RS-485 communication (SONOTEC protocol) 5 +0.5/-0.1VDC IP67 Up to 1.6 ms interval 10 Ms or less (faster response time is possible as needed) It detects bubbles over about 30 % of the inner diameter of the tube. ± 0.02 less than L/min (24 hours) 2.5 m Calibration certificate
SONOFLOW C3 Software (USB Data Converter / USB Cable Typea-B 2 M / USB Memory)
-20 ~ 70 ° C (10 to 95 % RH) * Dew condensation / freezing Tube material: PVC, Tube outer diameter: 4 to 16 mm 130
Ultrasonic flow meter for clamp -on type tubes SONOFLOW CO.56/XXX-Part Number-Co56/080

Co56/080

Available upon quote 9.0 x 6.0 Measurement unit: PMMA
Housing: Aluminum (gray)
Cover: SUS304 (red)
Water (23 ± 2 ℃)
* Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request.
Up to 150 mA * current must be limited to 250mA with fuses. □ 8.0 44 x 44 x 34 1,000-10,000 10 to 50 ° C Water, saline, human blood, transparent liquid Straight line: ± 5 % RD, reproducibility: ± 2 % RD IEC 60601-1 3rd edition, EMC standard (IEC 60601-1-2 4th edition) RS-485 communication (SONOTEC protocol) 5 +0.5/-0.1VDC IP67 Up to 1.6 ms interval 10 Ms or less (faster response time is possible as needed) It detects bubbles over about 30 % of the inner diameter of the tube. ± 0.02 less than L/min (24 hours) 2.5 m Calibration certificate
SONOFLOW C3 Software (USB Data Converter / USB Cable Typea-B 2 M / USB Memory)
-20 ~ 70 ° C (10 to 95 % RH) * Dew condensation / freezing Tube material: PVC, Tube outer diameter: 4 to 16 mm 135
Ultrasonic flow meter for clamp -on type tubes SONOFLOW CO.56/XXX-Part Number-Co56/120

Co56/120

Available upon quote 14.0 x 10.0 Measurement unit: PMMA
Housing: Aluminum (gray)
Cover: SUS304 (red)
Water (23 ± 2 ℃)
* Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request.
Up to 150 mA * current must be limited to 250mA with fuses. □ 12.0 44 x 44 x 36 1,200 ~ 12,000 10 to 50 ° C Water, saline, human blood, transparent liquid Straight line: ± 5 % RD, reproducibility: ± 2 % RD IEC 60601-1 3rd edition, EMC standard (IEC 60601-1-2 4th edition) RS-485 communication (SONOTEC protocol) 5 +0.5/-0.1VDC IP67 Up to 1.6 ms interval 10 Ms or less (faster response time is possible as needed) It detects bubbles over about 30 % of the inner diameter of the tube. ± 0.02 less than L/min (24 hours) 2.5 m Calibration certificate
SONOFLOW C3 Software (USB Data Converter / USB Cable Typea-B 2 M / USB Memory)
-20 ~ 70 ° C (10 to 95 % RH) * Dew condensation / freezing Tube material: PVC, Tube outer diameter: 4 to 16 mm 140
Ultrasonic flow meter for clamp -on type tubes SONOFLOW CO.56/XXX-Part Number-Co56/140

Co56/140

Available upon quote 16.0 x 12.0 Measurement unit: PMMA
Housing: Aluminum (gray)
Cover: SUS304 (red)
Water (23 ± 2 ℃)
* Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request.
Up to 150 mA * current must be limited to 250mA with fuses. □ 14.0 44 x 44 x 38 1,400 ~ 14,000 10 to 50 ° C Water, saline, human blood, transparent liquid Straight line: ± 5 % RD, reproducibility: ± 2 % RD IEC 60601-1 3rd edition, EMC standard (IEC 60601-1-2 4th edition) RS-485 communication (SONOTEC protocol) 5 +0.5/-0.1VDC IP67 Up to 1.6 ms interval 10 Ms or less (faster response time is possible as needed) It detects bubbles over about 30 % of the inner diameter of the tube. ± 0.02 less than L/min (24 hours) 2.5 m Calibration certificate
SONOFLOW C3 Software (USB Data Converter / USB Cable Typea-B 2 M / USB Memory)
-20 ~ 70 ° C (10 to 95 % RH) * Dew condensation / freezing Tube material: PVC, Tube outer diameter: 4 to 16 mm 145

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Krone Co., Ltd.


View more products of Krone Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree